Credit card payment only is accepted for this order because it contains a mix of both publications and training products.
Invalid username/password. Please try again.
xyz
THERMAL AND ACOUSTIC INSULATION OF HULL AND MACHINERY
:
Available format(s):
Superseded date: 08-06-2011
Language(s):
Published date: 12-01-2013
Publisher: UK Ministry of Defence Standards
TITLE PAGE SCOPE FOREWORD Sponsorship Conditions of Release General MOD Tender or Contract Process Related Documents Health and Safety Warning CONTENTS SECTION 1 - THERMAL INSULATION - GENERAL PRINCIPLESSECTION 2 - ACOUSTIC TREATMENT - GENERAL PRINCIPLES 2.1 Acoustic Absorption Treatment 2.2 Acoustic Insulation Treatment 2.3 Application of Acoustic Absorption and Insulation TreatmentSECTION 3 - SELECTION OF CONTRACTORS FOR THE THERMAL AND ACOUSTIC INSULATION OF HULL AND MACHINERYSECTION 4 - THERMAL INSULATION STRUCTURE SURFACE SHIPS 4.1 Areas to be Insulated 4.2 Surface Preparation 4.3 Insulation Type 4.4 Insulation Thickness - External Structure 4.5 Insulation Thickness - Internal Structure 4.6 Insulation Procedures 4.7 Insulation FinishSECTION 5 - ACOUSTIC TREATMENT STRUCTURE SURFACE SHIPS 5.1 Surface Preparation 5.2 Type of Treatment 5.3 Thickness of Treatment 5.4 Guidance Drawings 5.5 Installation Procedures 5.6 Treatment FinishSECTION 6 - THERMAL INSULATION STRUCTURE SUBMARINES 6.1 Areas to be insulated 6.2 Surface Preparation 6.3 Insulation Type 6.4 Insulation Thickness 6.5 Insulation Procedures 6.6 Insulation FinishSECTION 7 - FIRE BARRIER INSULATION 7.1 Areas to be insulated 7.2 Surface Preparation 7.3 Insulation Type 7.4 Insulation Thickness 7.5 Insulation Procedure 7.6 Insulation FinishSECTION 8 - THERMAL INSULATION VENTILATION TRUNKING SURFACE SHIPS 8.1 Areas to be Insulated 8.2 Surface Preparation 8.3 Insulation Type 8.4 Insulation Thickness 8.5 Insulation Procedures 8.6 F/R Cork Sheet Insulation 8.7 MFMB Insulation 8.8 Insulation FinishSECTION 9 - THERMAL INSULATION VENTILATION TRUNKING SUBMARINES 9.1 Areas to be insulated 9.2 Surface Preparation 9.3 Insulation Type 9.4 Insulation Procedures 9.5 Insulation FinishSECTION 10 - ACOUSTIC TREATMENT VENTILATION TRUNKING SURFACE SHIPS AND SUBMARINES 10.1 Areas to be treated 10.2 Surface Preparation 10.3 Type of treatment 10.4 Thickness of treatment 10.5 Installation ProceduresSECTION 11 - THERMAL AND ACOUSTIC INSULATION OF VOICE PIPES SURFACE SHIPS 11.1 Areas to be insulated 11.2 Surface Preparation 11.3 Insulation Type 11.4 Insulation Thickness 11.5 Insulation Procedures 11.6 Insulation FinishSECTION 12 - THERMAL INSULATION OF PIPING AT 80 DEGREES AND BELOW SURFACE SHIPS AND SUBMARINES 12.1 Areas to be insulated 12.2 Surface Preparation 12.3 Insulation Type 12.4 Insulation Thickness 12.5 Insulation Procedures 12.6 Insulation Finish - Surface Ships 12.7 Insulation Finish - Submarines 12.8 Importance of an effective vapour barrierSECTION 13 - THERMAL INSULATION OF PIPING ABOVE 80 DEGREES C - SURFACE SHIPS AND SUBMARINES 13.1 Areas to be insulated 13.2 Surface Preparation 13.3 Insulation Type 13.4 Insulation Thickness 13.5 Reference Drawings 13.6 Insulation Procedures 13.7 Insulation Finish Surface Ships Only 13.8 SubmarinesSECTION 14 - MODULAR INSULATION (MODLAG) - SURFACE SHIPS AND SUBMARINES 14.1 Introduction 14.2 Areas to be insulated 14.3 Surface Preparation 14.4 Insulation Type 14.5 Insulation Thickness 14.6 Design, Manufacture and Identification of MODLAGs 14.7 Insulation Procedures 14.8 Insulation FinishSECTION 15 - THERMAL INSULATION OF DRAINS FROM HOT EQUIPMENT - SURFACE SHIPS AND SUBMARINES 15.1 Areas to be insulated 15.2 Surface Preparation 15.3 Insulation Type 15.4 Insulation Thickness 15.5 Reference Drawings 15.6 Insulation Procedures 15.7 Insulation Finish 15.8 SUBMARINESSECTION 16 - THERMAL INSULATION OF STEAM TURBINE CYLINDERS, DRAIN COOLERS, HEAT EXCHANGERS, PUMPS - SURFACE SHIPS AND SUBMARINES 16.1 Areas to be insulated 16.2 Surface Preparation 16.3 Insulation Type 16.4 Insulation Thickness 16.5 Reference Drawings 16.6 Insulation Procedures 16.7 Insulation Finish 16.8 SUBMARINESSECTION 17 - THERMAL INSULATION OF WT BOILERS AND BACK UP INSULATION TO FURNACE LINING SURFACE SHIPS 17.1 Areas to be insulated 17.2 Surface Preparation 17.3 Insulation Type 17.4 Insulation Thickness 17.5 Insulation Procedures 17.6 Insulation FinishSECTION 18 - THERMAL INSULATION OF BOILER UPTAKES - SURFACE SHIPS 18.1 Areas to be insulated 18.2 Surface Preparation 18.3 Insulation Type 18.4 Insulation Thickness 18.5 Insulation Procedures 18.6 Finish to InsulationSECTION 19 - THERMAL INSULATION OF DIESEL ENGINE EXHAUST SYSTEMS - SURFACE SHIPS AND SUBMARINES 19.1 Areas to be insulated 19.2 Surface Preparation 19.3 Insulation Type 19.4 Insulation Thickness 19.5 Reference Drawings 19.6 Insulation Procedures 19.7 Insulation Finish - excluding integral insulationSECTION 20 - THERMAL AND ACOUSTIC INSULATION OF GAS TURBINE UPTAKES - SURFACE SHIPS 20.1 Areas to be insulated 20.2 Surface Preparation 20.3 Insulation Type 20.4 Insulation Thickness 20.5 Reference Drawings 20.6 Insulation Procedures 20.7 Insulation FinishANNEX A - RELATED DOCUMENTS ANNEX B - DEFINITIONS AND ABBREVIATIONS ANNEX C - EXPLANATORY NOTES TO ANNEX
Applicable to the thermal, fire barrier and acoustic insulation of the structure and, where appropriate, the systems, ventilation trunking and machinery of HM Ships and Submarines.
Sorry this product is not available in your region. p>
Unfortunately, this product is not available for purchase in your region.
Features
Get in touch with us
Loading..
A free alerting service to track changes to standards.
Once you've completed your purchase you'll get a link to My Orders on: -the Confirmation page of check out -and by email You'll be able to access your Multi User Orders to add Users.
You have selected more than three (3) participants. Please contact our Customer Service team.
You have already added this product in the cart. If you would like to add additional copies of this product please adjust the Quantity in the cart. For more than 10 copies, please contact our Customer Support team on +353 (0)1 857 6730.
You have selected more than three (3) trainings. Please contact our Customer Service team.Please contact our Customer Service team on Email: sales@saiglobal.com Phone: 131 242 (Within Australia)
You have already added a product with different Currency. Please change the currency.
This product cannot be added to your cart right now. Please contact our Customer Service team on Email: info@standards.iePhone: +353(0)1 857 6730
You have already saved 6 Quotes. Please contact our Customer Service Team.