DEFSTAN 02-125/2(2004) : 2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
REQUIREMENTS FOR NAAFI COMPARTMENTS IN HM SURFACE SHIPS AND SUBMARINES
26-04-2010
12-01-2013
TITLE PAGE
SCOPE
FOREWORD
Sponsorship
Conditions of Release
Categories of Naval Defence Standard
Related Documents
Health and Safety
Additional Information
CONTENTS
SECTION 1. DESIGN REQUIREMENTS
1.1 Compartment Size
1.2 Stowages
1.3 Racking and Shelving
1.4 Gangways
1.5 Access and Security
1.6 Service Hatches
1.7 Roller Shutters
1.8 Decorative Grilles
1.9 Waiting Areas
1.10 Machinery Equipment and Systems
1.11 Serving Counters, Benches
1.12 Stowage Gratings
1.13 Services and Finish
SECTION 2. BEER STORE - HM SURFACE SHIPS
2.1 Purpose
2.2 Location
2.3 Compartment Size
2.4 Equipment
2.5 Ready-Use Beer and Spirits Stowage - Senior Ratings
SECTION 3. BEER ISSUE CENTRE - HM SURFACE SHIPS
3.1 Purpose
3.2 Location
3.3 Compartment Size
3.4 Equipment
SECTION 4. CANTEEN/GIFT SHOP - HM SURFACE SHIPS
4.1 Purpose
4.2 Location
4.3 Compartment Size
4.4 Equipment
SECTION 5. CANTEEN STORE - HM SURFACE SHIPS
5.1 Purpose
5.2 Location
5.3 Compartment Size
5.4 Equipment
SECTION 6. VENDING MACHINES
6.1 Purpose
6.2 Location
6.3 Compartment Size
6.4 Equipment
SECTION 7. OTHER FACILITIES
7.1 HM Surface Ships
7.2 Submarines
SECTION 8. DRAWINGS
ANNEX A RELATED DOCUMENTS
ANNEX B ABBREVIATIONS AND DEFINITIONS
ANNEX C PROCUREMENT CHECK LIST
ALPHABETICAL INDEX
Specifies the requirements for the design and fitting out of compartments in HM Surface Ships normally administered by NAAFI personnel and compartments in Nuclear Submarines specifically for NAAFI merchandise.
DevelopmentNote |
Supersedes DEFSTAN 02-125/1(2000) (01/2005)
|
DocumentType |
Standard
|
PublisherName |
UK Ministry of Defence Standards
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
DEFSTAN 02-105(PT2)/2(2004) : 2004 | REQUIREMENTS FOR FITTING OUT OF OFFICES (EXCLUDING OPERATIONAL/COMMUNICATION OFFICES) IN HM SURFACE SHIPS AND SUBMARINES - PART 2: SPECIFIC REQUIREMENTS - HM SURFACE SHIPS |
DEFSTAN 02-105(PT2)/3(2010) : 2010 | REQUIREMENTS FOR FITTING OUT OF OFFICES (EXCLUDING OPERATIONAL/COMMUNICATION OFFICES) IN HM SURFACE SHIPS AND SUBMARINES - PART 2: SPECIFIC REQUIREMENTS HM SURFACE SHIPS |
DEFSTAN 02-157(PT2)/1(2000) : 2000 | REQUIREMENTS FOR DECK COVERINGS - PART 2: DECK/PREPARATION AND LAYING PROCEDURES CATEGORY 2 |
DEFSTAN 02-542(PT1)/1(2000) : 2000 | GUIDE TO DESIGN AND USER REQUIREMENTS OF INTERNAL COMMUNICATIONS SYSTEMS - PART 1: HM SURFACE SHIPS CATEGORY 2 |
DEFSTAN 07-251/1(2000) : 2000 | REQUIREMENTS FOR THE PRESERVATION AND PAINTING OF COMPARTMENTS IN SURFACE SHIPS - CATEGORY 2 |
DEFSTAN 02-130(PT2)/1(2000) : 2000 | REQUIREMENTS FOR DECORATIVE LININGS AND COMPOSITE BULKHEADS - PART 2: COMPOSITE BULKHEADS CATEGORY 2 |
DEFSTAN 08-160/1(2003) : 2003 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - CATEGORY 2 |
DEFSTAN 02-126(PT1)/2(2004) : 2004 | REQUIREMENTS FOR STORES COMPARTMENTS IN HM SURFACE SHIPS AND SUBMARINES - PART 1: GENERAL REQUIREMENTS |
DEFSTAN 08-109/2(2001) : 2001 | REQUIREMENTS FOR THE DESIGN OF ELECTRICAL SUPPLY AND DISTRIBUTION SYSTEMS IN SURFACE SHIPS AND SUBMARINES - CATEGORY 1 |
DEFSTAN 02-105(PT2)/2(2004) : 2004 | REQUIREMENTS FOR FITTING OUT OF OFFICES (EXCLUDING OPERATIONAL/COMMUNICATION OFFICES) IN HM SURFACE SHIPS AND SUBMARINES - PART 2: SPECIFIC REQUIREMENTS - HM SURFACE SHIPS |
DEFSTAN 02-130(PT1)/1(2000) : 2000 | REQUIREMENTS FOR DECORATIVE LININGS AND COMPOSITE BULKHEADS - PART 1: DECORATIVE LININGS CATEGORY 2 |
DEFSTAN 07-232(PT2)/1(2000) : 2000 | GUIDE TO DESIGN USE REQUIREMENTS OF INTERNAL COMMUNICATIONS SYSTEMS - CATEGORY 2 - PART 2: SUBMARINES |
DEFSTAN 02-722/1(2000) : 2000 | REQUIREMENTS FOR THE PREPARATION, IDENTIFICATION AND MANAGEMENTS OF DRAWINGS |
DEFSTAN 02-587(PT1)/2(2001) : INTERIM | REQUIREMENTS FOR LIGHTING SYSTEMS - PART 1: SURFACE SHIPS CATEGORY 3 |
DEFSTAN 02-107/2(2002) : 2002 | REQUIREMENTS FOR ACCOMMODATION IN HM SURFACE WARSHIPS AND SUBMARINES - CATEGORY 2 |
DEFSTAN 02-703/1(2000) : 2000 | THERMAL AND ACOUSTIC INSULATION OF HULL AND MACHINERY |
DEFSTAN 07-252/1(2000) : 2000 | REQUIREMENTS FOR THE PREPARATION AND PAINTING OF SUBMARINES - CATEGORY 2 |
DEFSTAN 02-126(PT2)/2(2004) : 2004 | REQUIREMENTS FOR STORES COMPARTMENTS IN HM SURFACE SHIPS AND SUBMARINES - PART 2: SPECIFIC REQUIREMENTS - HM SURFACE SHIPS |
DEFSTAN 02-126(PT3)/2(2004) : 2004 | REQUIREMENTS FOR STORES COMPARTMENTS IN HM SURFACE SHIPS AND SUBMARINES - PART 3: SPECIFIC REQUIREMENTS - HM SUBMARINES |
DEFSTAN 02-587(PT2)/1(2000) : 2000 | REQUIREMENTS FOR LIGHTING SYSTEMS - PART 2: SUBMARINES CATEGORY 3 |
DEFSTAN 02-157(PT1)/1(2000) : 2000 | REQUIREMENTS FOR DECK COVERINGS - PART 1: GENERAL REQUIREMENTS CATEGORY 2 |
DEFSTAN 02-105(PT1)/2(2004) : 2004 | REQUIREMENTS FOR FITTING OUT OF OFFICES (EXCLUDING OPERATIONAL/COMMUNICATION OFFICES) IN HM SURFACE SHIPS AND SUBMARINES - PART 1: GENERAL REQUIREMENTS |
DEFSTAN 02-102(PT1)/2(2000) : 2000 | REQUIREMENTS FOR AIR CONDITIONING & VENTILATION - PART 1: HM SURFACE SHIPS AND ROYAL FLEET AUXILIARIES |
DEFSTAN 02-538/1(2000) : 2000 | GUIDE TO THE SELECTION OF SMALL ELECTRICAL FITTINGS AND COMPONENTS CATEGORY 2 |
DEFSTAN 08-159(PT2)/1(2001) : 2001 | REQUIREMENTS FOR AIR-CONDITIONING AND VENTILATION - PART 2: HM SUBMARINES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.