DEFSTAN 59-411(PT3)/1(2007) : 2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTROMAGNETIC COMPATIBILITY - PART 3: TEST METHODS AND LIMITS FOR EQUIPMENT AND SUB SYSTEMS
Hardcopy , PDF
31-03-2014
English
01-01-2007
Foreword
Introduction
1 Scope
1.1 Man Worn/Man Portable Equipment
1.2 Line Replacement Units and Sub Systems
1.3 Support Equipment
1.4 Performance Specification for Specialised EMC Test
Equipment
2 Warning
3 Related Documents
4 Abbreviations and Definitions
4.1 Abbreviations
4.2 Definitions
5 Format
6 General Test Requirements
6.1 Introduction
6.2 Test Sites
6.3 Screened Rooms/Reverberation Chamber
6.4 Ground Conducting Bench
6.5 Power Supply Filtering
6.6 Power Supply Impedance
6.7 Layout of EUT
6.8 Length and Arrangement of Connecting Leads to EUT
6.9 Bonding of EUT
6.10 Ambient Electromagnetic Noise Levels
6.11 Ground Loop Currents in Measuring Leads
6.12 Input/Output Connections to the Equipment Under Test
6.13 Modes of Operation of Equipment Under Test
6.14 Test Frequency Selection
6.15 Measurement Bandwidth/Detector Function
6.16 Sweep Speeds and Plot Charts
6.17 Measuring Receiver Accuracy
6.18 Susceptibility Criteria
6.19 Susceptibility Test Stimuli
6.20 Operating Frequency of Equipment Under Test
6.21 Current Probes
6.22 Antennas
6.23 Measuring Sets
6.24 Measuring Cables
6.25 Oscilloscope
6.26 Signal Sources/Power Amplifiers
6.27 Transient Generators
6.28 Injection Transformers
6.29 Presentation of Results
6.30 Overload Precautions
6.31 RF Safety of Personnel
7 Classification of Equipment and Limits
7.1 Introduction
7.2 Equipment Types
7.3 Test Method Selection
7.4 Grading of Limits
7.5 Land Service Classifications
8 Applicability Requirements
9 Test Methods and Limits
9.1 Introduction
9.2 DCE01 Conducted Emission, Primary Power Lines
20 Hz - 150 MHz
9.3 DCE02 Conducted Emission, Control, Signal Lines
and Secondary Power Lines 20 Hz - 150 MHz
9.4 DCE03 Exported Transients, Primary Power Lines
9.5 DCS01 Conducted Susceptibility, Primary Power Lines
20 Hz - 50 KHz
9.6 DCS02 Conducted Susceptibility, Control, Signal and
Power Lines 50 kHz - 400 MHz
9.7 DCS03 Conducted Susceptibility, Control and Signal
Lines 20 Hz - 50 kHz
9.8 DCS04 Imported Transient Susceptibility (Air Services)
9.9 DCS05 Externally Generated Transients (Land and Sea
Services)
9.10 DCS06 Imported Long Transient Susceptibility AC and
DC Systems (Land and Sea Services)
9.11 DCS08 Externally Generated Transients (Air Services)
9.12 DCS09 Imported Lightning Transient Susceptibility (Air
Services)
9.13 DCS10 Electro Static Discharge (ESD)
9.14 DCS12 Imported Low Frequency Transient Susceptibility
Power Lines (Sea Services)
9.15 DRE01 Radiated Emissions Electric (E) Field 10 kHz - 18 GHz
9.16 DRE02 Radiated Emissions Magnetic (H) Field 20 Hz - 250 kHz
9.17 DRE03 Radiated Emissions Electric (E) Field Tuned Antenna
(Land Service) 1.6 MHz - 88 MHz
9.18 DRS01 Radiated Susceptibility Magnetic (H) Field
20 Hz - 100 kHz
9.19 DRS02 Radiated Susceptibility Electric (E) Field
10 kHz - 18 GHz
9.20 DRS03 Magnetic Field (DC) Susceptibility
Annex A Test Methods and Limits for Man Worn/Man Portable
Equipment
A.1 DCE02.A Conducted Emissions Control, Signal and Power
Lines 500 Hz - 150 MHz
A.2 DCS02.A Conducted Susceptibility Control, Signal and
Power Lines 50 kHz - 400 MHz
A.3 DCS10.A Electro Static Discharge (ESD)
A.4 DRE01.A Radiated Emissions E Field 88 MHz - 18 GHz
A.5 DRE02.A Radiated Emissions Magnetic (H) Field
500 Hz - 250 kHz
A.6 DRE03.A Radiated Emissions Electric (E) Field (Land
Services) Tuned Antenna 1.6 MHz - 88 MHz
A.7 DRS01.A Radiated Susceptibility Magnetic (H) Field
500 Hz - 100 kHz
A.8 DRS02.A Radiated Susceptibility Electric (E) Field
50 kHz - 18 GHz
Annex B Test Methods and Limits for LRU and Sub Systems
B.1 DCE01.B Conducted Emissions on Primary Power Lines
20 Hz - 150 MHz
B.2 DCE02.B Conducted Emissions Control, Signal and
Secondary Power Lines 20 Hz - 150 MHz
B.3 DCE03.B Exported Transients Primary Power Lines
B.4 DCS01.B Conducted Susceptibility Primary Power Lines
20 Hz - 50 kHz
B.5 DCS02.B Conducted Susceptibility, Control, Signal &
Power Lines 50 kHz - 400 MHz
B.6 DCS03.B Conducted Susceptibility, Control and Signal
Lines 20 Hz - 50 kHz
B.7 DCS04.B Imported Transient Susceptibility (Air Services)
B.8 DCS05.B Externally Generated Transients (Land and Sea
Services)
B.9 DCS06.B Imported Long Transient Susceptibility AC and
DC Systems (Land and Sea Services)
B.10 DCS08.B Externally Generated Transients (Air Services)
B.11 DCS09.B Imported Lightning Transient Susceptibility (Air
Services)
B.12 DCS10.B Electro Static Discharge (ESD)
B.13 DCS12.B Imported Low Frequency Transient Susceptibility
Power Lines (Sea Services)
B.14 DRE01.B Radiated Emissions Electric (E) Field
10 kHz - 18 GHz
B.15 DRE02.B Radiated Emissions Magnetic (H) Field
20 Hz - 100 kHz
B.16 DRE03.B Radiated Emissions E Field (Land Service) Tuned
Antenna 1.6 MHz - 30 MHz
B.17 DRS01.B Radiated Susceptibility Magnetic (H) Field
20 Hz - 100 kHz
B.18 DRS02.B Radiated Susceptibility Electric (E) Field
10 kHz - 18 GHz
B.19 DRS02.B Radiated Susceptibility, Electric (E) Field
Alternative Method (Air Services)
B.20 DRS03.B Magnetic Field (DC) Susceptibility (Land and
Sea Services)
Annex C Performance Specification for Specialised Test Equipment
C.1 Generators and Calibration Jigs
C.2 Transient Generator Performance Specifications
C.3 Injection Probe Performance
C.4 Calibration Jigs
C.5 Monitor Loops and Voltage Probes
C.6 Line Impedance Stabilizing Network (LISN)
C.7 Method For Damping Screened Rooms
C.8 Screened Room Damping Performance Verification Procedure
C.9 Voltage Probes
C.10 Antenna Calibration
Defines the preferred techniques to be used for the measurement of the electromagnetic compatibility characteristics to limit the propagation and coupling of unintentional electromagnetic energy whether conducted or radiated.
DevelopmentNote |
Supersedes DEFSTAN 59-41(PT3)SEC3/1(2003) and DEFSTAN 59-41(PT5)/3(2003). (02/2007) Supersedes DEFSTAN 08-136(PT1)/1(2000) and DEFSTAN 08-136(PT2)/1(2000). (03/2007)
|
DocumentType |
Standard
|
Pages |
220
|
PublisherName |
UK Ministry of Defence Standards
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
DEFSTAN 59-114(PT3)/1(2012) : 2012 | SAFETY PRINCIPLES FOR ELECTRICAL CIRCUITS IN SYSTEMS INCORPORATING EXPLOSIVE COMPONENTS - PART 3: ASSESSMENT, SAFETY MARGINS & TRIALS |
DEFSTAN 00-101(PT4)/2(2008) : 2008 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 4: GENERIC NAVAL ENVIRONMENT |
CLC/TR 50538:2010 | Guide to EMC Directive conformity of equipment designed for military purposes |
DEFSTAN 00-101(PT3)/2(2008) : 2008 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION |
DEFSTAN 02-309/3(2007) : 2007 | REQUIREMENTS FOR GAS TURBINES |
DEFSTAN 02-703/2(2011) : 2011 | THERMAL AND ACOUSTIC INSULATION OF HULL AND MACHINERY |
PD CLC/TR 50538:2010 | Guide to EMC Directive conformity of equipment designed for military purposes |
DEFSTAN 61-5(PT6)/6(2009) : 2009 | NOMINAL 12 V AND 24 V DC ELECTRICAL SYSTEMS IN MILITARY PLATFORMS |
S.R. CLC/TR 50538:2010 | |
DEFSTAN 23-10/1(2011) : 2011 | DESIGN GUIDELINES FOR MINISTRY OF DEFENCE SPECIALIST VEHICLES AND PLANT EQUIPMENT |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.