    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    NOMINAL 12 V AND 24 V DC ELECTRICAL SYSTEMS IN MILITARY PLATFORMS

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  28-03-2020

    Language(s):  English

    Published date:  01-01-2009

    Publisher:  UK Ministry of Defence Standards

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Warning
    3 Related Documents
    4 Abbreviations and Definitions
       4.1 Abbreviations
       4.2 Definitions
    5 Format
    6 Power Critical Design Review
       6.1 Purpose
       6.2 Platform Power Critical Design Review Requirements
       6.3 Platform and Terminal Equipment Power Critical Design
            Review Requirements
    7 Capacity
       7.1 Capacity Requirements
       7.2 Environmental Cable De-Rating
    8 Batteries
       8.1 Battery Requirements
    9 Circuit Protection
       9.1 Circuit Protection Requirements
    10 Wiring Configuration
       10.1 Cable Requirements
       10.2 Example Wiring Configuration
       10.3 Bespoke Platform Guidance
       10.4 Wiring Configuration Requirements
    11 Connections
       11.1 Connectors Recommendations
    12 Earthing
       12.1 Earthing Requirements
    13 Platform
       13.1 Platform Requirements
    14 Platform and Terminal Equipment
       14.1 Platform and Terminal Equipment Requirements
    15 Environmental
       15.1 Environmental Requirements
       15.2 Power Supply LRU/Component/Terminal Equipment Location
            and Test Temperature
    16 Quality Standard
       16.1 Quality Management System (QMS)
       16.2 UKAS Requirement
    17 Test Equipment
       17.1 Test Equipment Requirements
       17.2 Tolerances
    18 Electromagnetic Compatibility Legislation
    19 Management and Planning
       19.1 Management and Planning Requirements
       19.2 Control and Management
       19.3 Pass/Fail Criteria
    Annex A - Platform Power Distribution Tests
       A.1 General Requirements
       A.2 DET01.A Steady State Voltage
       A.3 DET02.A Ripple Voltage
       A.4 DET03.A Long Transients
       A.5 DET04.A Short Transients
       A.6 DET05.A Circuit Protection
       A.7 DET06.A Power Distribution Voltage Drop
       A.8 DET07.A Cranking
       A.9 DET08.A Terminal Equipment Battery Capacity Test
       A.10 DIT01.A Platform/Terminal Earth Bond
       A.11 DIT02.A Platform Over Voltage/Regulator Failure
       A.12 DIT03.A Platform Imported Ripple (20Hz - 150kHz)
       A.13 DIT04.A Platform Load Dump
    Annex B - Platform and Terminal Equipment Tests
       B.1 General Requirements
       B.2 DET01.B Ripple
       B.3 DET02.B Exported Transients
       B.4 DET03.B Maximum Inrush Current
       B.5 DIT01.B Positive Supply Isolation Test
       B.6 DIT02.B Earth Bonding
       B.7 DIT03.B Negative/Earth Bond Isolation
       B.8 DIT04.B Cranking
       B.9 DIT05.B Reverse Voltage
       B.10 DIT06.B Under & Over-Voltage
       B.11 DIT07.B Short Transients
       B.12 DIT08.B Load Dump
    Annex C - Related Documents
       C.1 Related Documents
    Annex D - Abbreviations
       D.1 Abbreviations
    Annex E - Cable Capacity De-Rating Factors
       E.1 De-Rating Factors
    Annex F - Power Critical Design Review - Example Forms
       F.1 Amendment Status
       F.2 Document History
       F.3 Distribution List
       F.4 PROJECT INFORMATION
       F.5 Documents
       F.6 Platform Details
       F.7 Platform Working Environment
       F.8 Platform and Terminal Equipment Power Distribution
            Systems Requirements
       F.9 Earthing Strategy
       F.10 Circuit Protection
       F.11 Connections
       F.12 Installed Equipment
       F.13 Test Requirements
       F.14 Test Applicability
    Annex G - Platform and Terminal Equipment Power Critical
              Design Review - Example Documents
       G.1 Equipment Details
       G.2 Amendment Status
       G.3 Document History
       G.4 Distribution List
       G.5 Introduction
       G.6 Contact Details
       G.7 Documents
       G.8 Platform or Terminal Equipment Details
       G.9 Platform and Terminal Equipment Working Environment
       G.10 Platform and Terminal Equipment Design Requirements
       G.11 Connectors
       G.12 Test Requirements

    Abstract - (Show below) - (Hide below)

    Describes defines the characteristics for all military (ground) platform DC power distribution systems, platform and terminal equipment within the military, bespoke, military off the shelf (MOTS) and commercial off the shelf (COTS) vehicular environment.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DEFSTAN 61-5(PT6)/5(1990). (03/2009)
    Document Type Standard
    Publisher UK Ministry of Defence Standards
    Status Withdrawn
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    DEFSTAN 59-411(PT1)/2(2014) : 2014 ELECTROMAGNETIC COMPATIBILITY - PART 1: MANAGEMENT AND PLANNING
    DEFSTAN 23-09/2(2011) : 2011 GENERIC VEHICLE ARCHITECTURE (GVA)
    DEFSTAN 02-327/4(2016) : 2016 STANDARDS FOR DEFENCE REQUIREMENTS AND GUIDANCE FOR THE PROCUREMENT OF PUMPS FOR AUXILIARY SYSTEMS
    DEFSTAN 23-09(PT1)/3(2013) : 2013 GENERIC VEHICLE ARCHITECTURE (GVA) - PART 1: INFRASTRUCTURE
    DEFSTAN 23-009(PT0)/4(2016) : 2016 GENERIC VEHICLE ARCHITECTURE (GVA) - PART 0: GVA APPROACH
    DEFSTAN 23-09(PT0)/3(2013) : 2013 GENERIC VEHICLE ARCHITECTURE (GVA) - PART 0: GVA APPROACH
    AECTP-250 : 2014 ELECTRICAL AND ELECTROMAGNETIC ENVIRONMENTAL CONDITIONS

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    DEFSTAN 00-35(PT4)/4(2006) : 2006 ENVIRONMENTAL HANDBOOK FOR DEFENCE MATERIEL - PART 4: NATURAL ENVIRONMENTS
    ISO 7637-3:2016 Road vehicles — Electrical disturbances from conduction and coupling — Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    ISO 7637-1:2015 Road vehicles — Electrical disturbances from conduction and coupling — Part 1: Definitions and general considerations
    STANAG 2601 : 2017 STANDARDIZATION OF ELECTRICAL SYSTEMS IN TACTICAL LAND VEHICLES
    DEFSTAN 00-35(PT6)/4(2006) : 2006 ENVIRONMENTAL HANDBOOK FOR DEFENCE MATERIEL - PART 6: INDUCED CLIMATIC, CHEMICAL AND BIOLOGICAL ENVIRONMENTS
    DEFSTAN 23-6/4(2005) : 2005 TECHNOLOGY GUIDANCE FOR MILITARY LOGISTICS VEHICLES
    ISO 7637-2:2011 Road vehicles Electrical disturbances from conduction and coupling Part 2: Electrical transient conduction along supply lines only
    DEFSTAN 59-411(PT4)/1(2007) : 2007 ELECTROMAGNETIC COMPATIBILITY - PART 4: PLATFORM AND SYSTEM TEST AND TRIALS
    VG 95218-5 : 2007 ELECTRICAL CABLES AND INSULATED WIRES - PART 5: CURRENT RATING
    DEFSTAN 00-35(PT3)/4(2006) : 2006 ENVIRONMENTAL HANDBOOK FOR DEFENCE MATERIEL - PART 3: ENVIRONMENTAL TEST METHODS
    DEFSTAN 59-411(PT3)/1(2007) : 2007 ELECTROMAGNETIC COMPATIBILITY - PART 3: TEST METHODS AND LIMITS FOR EQUIPMENT AND SUB SYSTEMS
    AQAP 2000 : 2009 NATO POLICY ON AN INTEGRATED SYSTEMS APPROACH TO QUALITY THROUGH THE LIFE CYCLE
    DEFCON 602A : 2006 QUALITY ASSURANCE (WITH DELIVERABLE QUALITY PLAN)
    ISO 9001:2015 Quality management systems — Requirements
    SAE AS 50881 : 2015 WIRING AEROSPACE VEHICLE
    ISO/IEC Guide 2:2004 Standardization and related activities General vocabulary
    DEFCON 602B : 2006 QUALITY ASSURANCE (WITHOUT DELIVERABLE QUALITY PLAN)
    DEFSTAN 59-411(PT1)/1(2007) : 2007 ELECTROMAGNETIC COMPATIBILITY - PART 1: MANAGEMENT AND PLANNING
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective