Vorwort
1 Anwendungsbereich
2 Normative Verweisungen
3 Begriffe
4 Klassifizierung
4.1 Allgemeines
4.2 Klassifizierung elektromechanischer Schlösser
und Schliessbleche
4.3 Gebrauchskategorie (erste Stelle)
4.4 Dauerfunktionstüchtigkeit und Belastung der
Falle (zweite Stelle)
4.5 Türmasse und Schliesskraft (dritte Stelle)
4.6 Eignung für die Verwendung an
Feuerschutz-/Rauchschutztüren (vierte Stelle)
4.7 Sicherheit (fünfte Stelle)
4.8 Korrosionsbeständigkeit, Temperatur und
Luftfeuchtigkeit (sechste Stelle)
4.9 Schutzwirkung (siebente Stelle)
4.10 Schutzwirkung - elektrische Funktionsweise
(achte Stelle)
4.11 Schutzwirkung - elektrische Manipulation
(neunte Stelle)
5 Anforderungen
5.1 Allgemeines
5.2 Gebrauchskategorie
5.3 Dauerfunktionstüchtigkeit
5.4 Türmasse und Schliesskraft
5.5 Eignung zur Verwendung an
Feuerschutz-/Rauchschutztüren
5.6 Sicherheit
5.7 Korrosionsbeständigkeit, Temperatur und
Luftfeuchtigkeit
5.8 Anforderungen an die Schutzwirkung
5.9 Schutzwirkung - Elektrische
Wirkungsweise - Zustandsanzeige
5.10 Schutzwirkung - Elektrische Manipulation
5.11 Anforderungen an die Produktinformation
6 Prüfverfahren
6.1 Durchführung der Prüfung
6.2 Gebrauchskategorie-Prüfungen
6.3 Dauerfunktionstüchtigkeits-Prüfungen
6.4 Türmasse und Schliesskraft
6.5 Feuer-/Rauchwiderstands-Prüfungen
6.6 Sicherheit
6.7 Korrosionsbeständigkeit, Temperatur und
Luftfeuchtigkeit
6.8 Schutzwirkungs-Prüfungen
6.9 Schutzwirkung - Anforderungen an die elektrische
Funktionsweise - Zustandsanzeige
6.10 Schutzwirkung - Anforderungen hinsichtlich
elektrischer Manipulation
7 Kennzeichnung
8 Konformitätsbewertung
8.1 Erstprüfung
8.2 Probenahme, Prüfung und Konformitätskriterien
8.3 Werkseigene Produktionskontrolle
8.4 Periodische Prüfung
8.5 Jährliche Prüfung
Anhang A (normativ) Feuer-/Rauchschutz-Prüfungsanforderungen
Anhang B (normativ) Auswahl der Prüflinge und Prüfreihenfolge
Anhang C (normativ) Einbau- und Befestigungsanweisungen
Anhang ZA (normativ) Abschnitte dieser Europäischen
Norm, die Bestimmungen der EG-Bauproduktenrichtlinie
(89/106/EWG) betreffen
Literaturhinweise
This standard is included in DIN Handbook 253.
DevelopmentNote |
Supersedes DIN EN 12209-3. (11/2008) DRAFT 2015 issued in July 2015. (07/2015)
|
DocumentType |
Draft
|
Pages |
196
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
EN 14846:2008 | Identical |
EN 1906:2012 | Building hardware - Lever handles and knob furniture - Requirements and test methods |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 1303:2015 | Building hardware - Cylinders for locks - Requirements and test methods |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 12209:2016 | Building hardware - Mechanically operated locks and locking plates - Requirements and test methods |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 12320:2012 | Building hardware - Padlocks and padlock fittings - Requirements and test methods |
PREN 13637 : DRAFT 2014 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
ISO 9001:2015 | Quality management systems — Requirements |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.