DIN EN 54-22:2015-07
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS
Hardcopy , PDF
01-07-2020
English, German
01-01-2015
National foreword
National Annex NA (informative) - Bibliography
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Product characteristics
5 Testing, assessments and sampling methods
6 Assessment and verification of constancy of
performance (AVCP)
7 Classification
8 Marking, labelling and packaging
Annex A (normative) - Arrangement of the sensing
element in the fire test room
Annex B (normative) - Flaming liquid test fires (TF6F,
TF6 and TF6S)
Annex C (normative) - Test arrangement for the sensing
element of linear heat detector in the heat tunnel
Annex D (informative) - Apparatus for mounting of
the sensing element of linear heat detector in the
heat tunnel
Annex E (normative) - Mounting of the sensing element
of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time
and response temperature measurements
Annex G (informative) - Construction of the heat tunnel
Annex H (normative) - Test arrangement for vibration
tests for sensing element
Annex I (normative) - Test apparatus for impact test
on the sensing element
Annex J (informative) - Data supplied with resettable
line-type heat detectors
Annex ZA (informative) - Clauses of this European
Standard addressing the provisions of the EU
Construction Products Regulation
Bibliography
Pertains to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works
DevelopmentNote |
DRAFT AMD 1 issued in June 2017. (06/2017)
|
DocumentType |
Standard
|
Pages |
85
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
Standards | Relationship |
EN 54-22:2015 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
VDE 0833-2 :2017-10 | ALARM SYSTEMS FOR FIRE, INTRUSION AND HOLD UP - PART 2: REQUIREMENTS FOR FIRE ALARM SYSTEMS |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
DIN VDE 0833-2:2017-10 | ALARM SYSTEMS FOR FIRE, INTRUSION AND HOLD UP - PART 2: REQUIREMENTS FOR FIRE ALARM SYSTEMS |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.