• DIN EN 60601-2-4 : 2012

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    MEDICAL ELECTRICAL EQUIPMENT - PART 2-4: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CARDIAC DEFIBRILLATORS (IEC 60601-2-4:2010)

    Available format(s): 

    Superseded date:  04-09-2021

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Verband Deutscher Elektrotechniker

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    SECTION ONE - GENERAL
    1 Scope and object
    2 Terminology and definitions
    4 General requirements for tests
    5 Classification
    6 Identification, marking and documents
    SECTION TWO - ENVIRONMENTAL CONDITIONS
    10 Environmental conditions
    SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK
    HAZARDS
    14 Requirements related to classification
    17 Separation
    19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY
        CURRENTS
    20 Dielectric strength
    SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
    SECTION FIVE - PROTECTION AGAINST HAZARDS FROM
    UNWANTED OR EXCESSIVE RADIATION
    36 Electromagnetic compatibility (EMC)
    SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF
    FLAMMABLE ANAESTHETIC MIXTURES
    SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES
    AND OTHER SAFETY HAZARDS
    42 Excessive temperatures
    44 Overflow, spillage, leakage, humidity, ingress of
        liquids, cleaning, sterilization, disinfection and
        compatibility
    46 Human errors
    SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION
    AGAINST HAZARDOUS OUTPUT
    50 Accuracy of operating data
    51 Protection against hazardous output
    SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS;
    ENVIRONMENTAL TESTS
    52 Abnormal operation and fault conditions
    SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
    56 Components and general assembly
    57 MAINS PARTS, components and layout
    SECTION 101 - ADDITIONAL REQUIREMENTS RELATING TO SAFETY
    101 Charging time
    102 Internal electrical power source
    103 Endurance
    104 Synchronizer
    105 Recovery of the MONITOR/ECG INPUT after defibrillation
    106 Disturbance to the monitor from charging or internal
        discharging
    Appendix L References - Publications mentioned in this
               Standard
    Annex AA (informative) General guidance and rationale
    Annex BB (informative) AUTOMATED EXTERNAL DEFIBRILLATORS:
             background and rationale
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             publications
    Annex ZB (informative) Other international publications
             mentioned in this standard with the reference of
             the European publications

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DIN IEC 62D-181-CD and DIN VDE 0750-201. (07/2003) Applies in conjunction with DIN EN 60601-1 issue 07-2007. Supersedes DIN IEC 60601-2-4. (06/2012) DRAFT AMD 1 issued in February 2017. (02/2017)
    Document Type Standard
    Publisher Verband Deutscher Elektrotechniker
    Status Superseded
    Superseded By
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective