• DIN EN 60664-5 : 2008

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 5: COMPREHENSIVE METHOD FOR DETERMINING CLEARANCES AND CREEPAGE DISTANCES EQUAL TO OR LESS THAN 2 MM

    Available format(s): 

    Withdrawn date:  01-01-2016

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Verband Deutscher Elektrotechniker

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 General
      1.1 Scope
      1.2 Normative references
      1.3 Definitions
    2 Fundamentals of clearance and creepage distance dimensioning
      2.1 Introduction
      2.2 Voltages and voltage ratings
      2.3 Frequency
      2.4 Time under voltage stress
      2.5 Pollution
      2.6 Information supplied with the equipment
      2.7 Insulating material
    3 Requirements and dimensioning procedures
      3.1 Dimensioning of clearances
      3.2 Dimensioning of creepage distances
      3.3 Requirements for design of solid insulation
    4 Tests and measurements
      4.1 Tests
      4.2 Measurement of creepage distances and clearances
    Annex A (informative) Basic data on withstand characteristics
            of clearances
    Annex B (informative) Nominal voltages of supply systems for
            different modes of overvoltage control
    Annex C (informative) Partial discharge test methods
    Annex D (informative) Additional information on partial discharge
            test methods
    Annex E (informative) Comparison of creepage distances specified
            in Table 4 and clearances in Table A.1
    Annex F (informative) Dimensioning to maintain minimum insulation
            resistance
    Annex G (normative) Water adsorption test
    Annex H (informative) Dimensioning diagrams
    Annex I (informative) Withstand voltage test for creepage distance
            under humid conditions
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             publications
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearance and the creepage distance are identical and are along the surface of solid insulation.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DIN IEC 28A-143A-NP. Applies only in conjunction with DIN EN 60664-1. (04/2004)
    Document Type Standard
    Publisher Verband Deutscher Elektrotechniker
    Status Withdrawn
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective