• NF EN 60664-5 : 2008

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 5: COMPREHENSIVE METHOD FOR DETERMINING CLEARANCES AND CREEPAGE DISTANCES EQUAL TO OR LESS THAN 2 MM

    Available format(s): 

    Withdrawn date:  13-06-2015

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    AVANT-PROPOS
    INTRODUCTION
    1 Domaine d'application et objet
    2 Références normatives
    3 Termes et définitions
    4 Principes essentiels du dimensionnement des distances
      d'isolement et des lignes de fuite
      4.1 Remarques préliminaires
      4.2 Principes de base
      4.3 Tensions et caractéristiques assignées de tension
      4.4 Fréquence
      4.5 Durée d'application de la contrainte de tension
      4.6 Pollution
      4.7 Informations fournies avec le matériel
      4.8 Matériau isolant
    5 Exigences et procédures de dimensionnement
      5.1 Généralités
      5.2 Dimensionnement des distances d'isolement
      5.3 Dimensionnement des lignes de fuite
      5.4 Exigences pour l'isolation solide
    6 Essais et mesures
      6.1 Essais
      6.2 Mesure des lignes de fuite et des distances d'isolement
    Annexe A (informative) Dimensionnement pour maintenir la
             résistance d'isolement minimale
    Annexe B (normative) Essai d'adsorption d'eau
    Annexe C (informative) Schémas de dimensionnement
    Annexe D (informative) Essai de tension de tenue pour ligne
             de fuite dans des conditions humides
    Annexe ZA (normative) Références normatives à d'autres
              publications internationales avec les publications
              européennes correspondantes
    Bibliographie

    Abstract - (Show below) - (Hide below)

    Describes the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearance and the creepage distance are identical and are along the surface of solid insulation.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de classement: C20-040-5. PR NF EN 60664-5 December 2001. (01/2002) PR NF EN 60664-5 September 2006. (09/2006)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    NF EN 60664-1 : 2007 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS
    NF EN 60664-4 : 2006 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS

    Standards Referencing This Book - (Show below) - (Hide below)

    NF EN 60721 3-9 : 93 AMD 1 95 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 9: MICROCLIMATES INSIDE PRODUCTS
    IEC 60721-3-9:1993 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 9: Microclimates inside products
    NF EN 60721 3-7 : 95 AMD 1 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 7: PORTABLE AND NON-STATIONARY USE
    NF EN 60664-1 : 2007 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS
    IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
    IEC 60721-3-7:1995+AMD1:1996 CSV Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use
    IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    NF EN 60721 3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 3: STATIONARY USE AT WEATHER-PROTECTED LOCATIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective