LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 2: LINES USING METALLIC CONDUCTORS
30-11-2022
12-01-2013
FOREWORD
INTRODUCTION
Clause
1 Scope and object
2 Normative references
3 Definitions
4 Reference configuration
5 Environmental factor Ke, installation factor Ki,
shielding factor Ks and conventional transition
point length LcT
5.1 Environmental factor Ke
5.2 Installation factor Ki
5.3 Shielding factor Ks
5.4 Conventional transition point length LcT
6 Protection need
6.1 General
6.2 Protection need against indirect lightning to
the telecommunication line
6.3 Protection need against direct lightning to the
structure that the telecommunication line enters
6.4 Protection need against direct lightning to the
telecommunication line
7 Protection measures
7.1 General
7.2 Protective measures against indirect lightning
to the telecommunication line
7.3 Protective measures against direct lightning to
the structure that the telecommunication line enters
7.4 Protective measures against direct lightning to
the telecommunication lines
Annex A (normative) Procedure for evaluating the
protection needs against lightning of
telecommunication or signal lines using
metallic conductors
Annex B (normative) Resistance value of the cable shield
connection to earth along the telecommunication
line
Annex C (normative) Evaluation of the lightning current
I striking the structure which causes damage
to the telecommunication line entering the structure
Annex D (informative) Overvoltages, overcurrents and
frequency of damage Fp on a telecommunication line
Annex E (informative) Relative amount of expected
losses per damage
Annex F (informative) Application of protection need
requirements: examples
Annex G (informative) Environmental factor Ke
Annex H (informative) Risk of damage Rp
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Pertains to protection against lightning of outdoor telecommunication lines using metallic conductors (for example, access networks, lines between buildings). It aims to protect telecommunication lines and connected equipment against the direct and indirect influence of lightning by limiting the risk of damage due to overvoltages and overcurrents, liable to occur in these lines, to values which are lower than or equal to the tolerable risk of damage.
DocumentType |
Standard
|
PublisherName |
Verband Deutscher Elektrotechniker
|
Status |
Withdrawn
|
Standards | Relationship |
NBN EN 61663-2 : 2001 | Identical |
NF EN 61663-2 : 2001 | Identical |
VDE 0845-4-2 : 2002 | Corresponds |
BS EN 61663-2:2001 | Identical |
EN 61663-2 : 2001 | Identical |
I.S. EN 61663-2:2001 | Identical |
UNE-EN 61663-2:2003 | Identical |
IEC 61663-2:2001 | Identical |
VDE 0845-4-2 : 2002 | Identical |
DIN EN 61663-1 : 2000 | LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1: FIBRE OPTIC INSTALLATIONS |
VDE 0845-4-1 : 2000 | LIGHTING PROTECTION - TELECOMMUNICATION LINES - FIBRE OPTIC INSTALLATIONS A FIBRES OPTIQUES |
DIN 56950-1:2012-05 | ENTERTAINMENT TECHNOLOGY - MACHINERY INSTALLATIONS - PART 1: SAFETY REQUIREMENTS AND INSPECTIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.