• DIN VDE 0298-300 : 2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES

    Available format(s): 

    Superseded date:  01-02-2015

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Verband Deutscher Elektrotechniker

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Einleitung
    1 Anwendungsbereich
    2 Normative Verweisungen
    3 Definitionen
    4 Sicherheitsanforderungen
      4.1 Grundsätzliche Anforderungen
      4.2 Allgemeine Anforderungen
      4.3 Anforderungen bei Leitungen für feste Verlegung
      4.4 Anforderungen an flexible Leitungen
    5 Grenzbedingungen
      5.1 Spannung
      5.2 Strombelastbarkeit
      5.3 Thermische Einflüsse
      5.4 Mechanische Beanspruchung
      5.5 Verträglichkeit
      5.6 Beanspruchungen durch Stromkräfte
    6 Erst- und regelmässige Wiederholungsprüfungen
    7 Verpackung, Lagerung sowie Handhabung/Transport
      7.1 Verpackung
      7.2 Lagerung
      7.3 Handhabung/Transport
    Tabellen 1A bis 11
    Anhang A (normativ) Begriffe
    Anhang B (normativ) Einteilung der Beanspruchung
    Anhang C (normativ) Einteilung äusserer Einflüsse -
             Umgebungsbedingungen (Auszüge)
    Anhang D (informativ) Literaturhinweise

    Abstract - (Show below) - (Hide below)

    Ziel der Veröffentlichung dieser Norm ist es, die Anwender über die Eigenschaften und Grenzbedingungen harmonisierter isolierter Starkstromleitungen zu unterrichten, um Missbrauch der Leitungen zu vermeiden.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Verband Deutscher Elektrotechniker
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    DIN VDE 0282-807 : 1994 RUBBER INSULATED CABLES, WIRES AND FLEXIBLE CORDS FOR POWER INSTALLATION - RUBBER INSULATED LIFT CABLES 05RT AND 05RN
    DIN VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
    DIN VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
    VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF NOMINAL VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
    VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
    VDE 0551 : 1995 ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS
    VDE 0281-12 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - CABLES SOUPLES RESISTANT A LA CHALEUR
    VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
    VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 7: SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREES C
    VDE 0281-10 : 2003 POLYVINYLCHLORID-ISOLIERTE STARKSTROMLEITUNGEN MIT NENNSPANNUNGEN BIS 450/750 V WENDELLEITUNGEN
    DIN EN 60742 : 1995 ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS
    DIN VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREE C POUR FILERIE INTERNE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective