• EN 1047-2:2009+A1:2013

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Secure storage units - Classification and methods of test for resistance to fire - Part 2: Data rooms and data container

    Available format(s): 

    Superseded date:  22-02-2022

    Language(s): 

    Published date:  13-02-2013

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements and classification
    5 Test specimens, technical documentation, material
      samples, physical fittings and correlation
    6 Test methods
    7 Labelling
    Bibliography

    Abstract - (Show below) - (Hide below)

    This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified.Requirements are also specified for test specimens, the technical documentation of the test specimens, materials specimens, physical fittings, the correlation of test specimens with the technical documentation and the preparation for type testing as well as test procedures.In addition, a scheme to classify data rooms and data containers from the test results is given (see Table 2).As well as providing protection against fire, correctly installed data rooms and data containers offer protection against impacts caused by failure during fire of components and objects external to the data room or data container.Data rooms and data containers having the same design, protection and construction features (type and thickness of construction and protective materials, rebate geometry, lockings, doors, etc.) will only be given the same protection classification as that of the test specimen if the tolerances are within the ranges specified in Table 1.NOTEThis European Standard does not regulate the use of data rooms in the meaning of the building laws of the respective countries. In the construction of data rooms, the respective national requirements should be considered.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 263
    Development Note Supersedes UNE EN 1047-2. (01/2010) 2009 Edition Re-Issued in February 2013 & incorporates AMD 1 2013. (02/2013)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    PREN 50600-2-5 : DRAFT 2012 BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    I.S. EN 50600-2-5:2016 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    EN 50600-2-5:2016 Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems
    ISO/IEC TS 22237-6:2018 Information technology — Data centre facilities and infrastructures — Part 6: Security systems
    12/30274114 DC : 0 BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    CEI EN 50600-2-5 : 2017 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 1047-1:2005 Secure storage units - Classification and methods of test for resistance to fire - Part 1: Data cabinets and diskette inserts
    EN 1365-1:2012/AC:2013 FIRE RESISTANCE TESTS FOR LOADBEARING ELEMENTS - PART 1: WALLS
    EN 1364-1:1999 Fire resistance tests for non-loadbearing elements - Part 1: Walls
    EN 61515:2016 Mineral insulated metal-sheathed thermocouple cables and thermocouples
    IEC 61515:2016 Mineral insulated metal-sheathed thermocouple cables and thermocouples
    EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
    EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
    EN 206-1:2000/A2:2005 CONCRETE - PART 1: SPECIFICATION, PERFORMANCE, PRODUCTION AND CONFORMITY
    EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
    IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
    EN 1365-2:2014 Fire resistance tests for loadbearing elements - Part 2: Floors and roofs