EN 12843:2004
Current
The latest, up-to-date edition.
Precast concrete products - Masts and poles
02-09-2004
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Material requirements
4.1.1 General
4.1.5 Inserts and connectors
4.2 Production requirements
4.3 Finished product requirements
4.3.1 Geometrical properties
4.3.2 Surface characteristics
4.3.3 Mechanical resistance
4.3.4 Resistance and reaction to fire
4.3.7 Durability
4.3.8 Detailing
4.3.9 Earth
5 Test methods
5.1 Tests on concrete
5.2 Measuring of dimensions and surface characteristics
5.2.1 Appearance of surface finish
5.2.2 Measurement of dimensions
5.4 Concrete cover
5.5 Mechanical resistance, verification by testing
5.5.1 General
5.5.2 Bending test
5.5.4 Torsion test
6 Evaluation of conformity and compliance criteria
6.1 General
6.2 Type testing
6.3 Factory production control
7 Marking and labelling
8 Technical documentation
8.1 General
8.2 Handling, storage and transportation
8.3 Traceability
Annex A (normative) Inspection scheme
Annex B (normative) Concrete cover
Annex Y (informative) Choice of CE marking method
Y.1 General
Y.2 Method 1
Y.3 Method 2
Y.4 Method 3
Annex ZA (informative) Relationship between this European
Standard and the Essential Requirements of EU Directive
ZA.1 Scope and relevant characteristics
ZA.2 Procedure for attestation of conformity of masts and
poles
ZA.2.1 System of attestation of conformity
ZA.2.2 EC Certificate and Declaration of conformity
ZA.3 CE marking and labelling
ZA.3.1 General
ZA.3.2 Declaration of geometrical data and material
properties
ZA.3.3 Declaration of product properties
ZA.3.4 Declaration of compliance with a given design
specification
Bibliography
This Standard specifies requirements for precast concrete poles (also commonly called masts) (either all of a piece or composed of elements), reinforced and/or prestressed as structural elements; they may be hollow or solid and may receive or include additional components (e.g. cross-arms, platforms etc.), inserts and connectors. Additional elements may be connected to pole elements.Structures made from such elements in mono- or multi-legged form may be used for :- overhead electrical lines ;- telecommunication lines ;- overhead electrical lines for railways, trams and similar ;- supports for lighting ;- supports for loudspeaker installation ;- antenna and telecommunication poles ;- supports for wind turbines ;- and similar installations.This Standard does not cover lighting columns for use in traffic circulation areas.
Committee |
CEN/TC 229
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN 12843 : 2005 | Identical |
DIN EN 12843:2004-11 | Identical |
UNI EN 12843 : 2005 | Identical |
SN EN 12843 : 2004 | Identical |
BS EN 12843:2004 | Identical |
NBN EN 12843 : 2004 | Identical |
UNE-EN 12843:2005 | Identical |
NEN EN 12843 : 2004 | Identical |
NS EN 12843 : 1ED 2004 | Identical |
I.S. EN 12843:2004 | Identical |
PN EN 12843 : 2008 | Identical |
UNE-EN 50341-1:2017 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
PREN 50119 : DRAFT 2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications |
EN 50423-1:2005 | Overhead electrical lines exceeding AC 1 kV up to and including AC 45 kV - Part 1: General requirements - Common specifications |
BS EN 50119 : 2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
11/30215604 DC : 0 | BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
I.S. EN 50341-1:2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
I.S. EN 50119:2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
NF EN 50119 : 2010 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 50423-1:2005 | Overhead electrical lines exceeding AC 1 kV up to and including AC 45 kV General requirements. Common specifications |
IEC 60913:2013 | Railway applications - Fixed installations - Electric traction overhead contact lines |
CEI EN 50341-1 : 2013 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
12/30260570 DC : 0 | BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
17/30341013 DC : DRAFT AUG 2017 | BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
I.S. EN 50119:2020 | Railway applications - Fixed installations - Electric traction overhead contact lines |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
PREN 50341-1 : DRAFT 2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
I.S. EN 50423-1:2005 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV UP TO AND INCLUDING AC 45 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
EN 12390-5:2009 | Testing hardened concrete - Part 5: Flexural strength of test specimens |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 10544:1992 | Cold-reduced steel wire for the reinforcement of concrete and the manufacture of welded fabric |
ENV 13670-1 : DRAFT 2000 | EXECUTION OF CONCRETE STRUCTURES - PART 1 - COMMON |
ISO 1803:1997 | Building construction Tolerances Expression of dimensional accuracy Principles and terminology |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.