• There are no items in your cart

EN 13030:2001

Current

Current

The latest, up-to-date edition.

Ventilation for buildings - Terminals - Performance testing of louvres subjected to simulated rain

Published date

10-10-2001

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and subscripts
  4.1 Symbols
  4.2 Subscripts
5 Instrumentation
  5.1 Air flow rate measurement
  5.2 Wind Velocity Measurement
  5.3 Pressure Measurement
  5.4 Temperature measurement
  5.5 Water flow meters
  5.6 Timers
  5.7 Rain gauge
6 Test apparatus
  6.1 General
  6.2 Win simulation equipment
  6.3 Weather section
  6.4 Rain simulation equipment
  6.5 Collection duct
  6.6 Water collection
  6.7 Aerodynamic measurement section
  6.8 Mechanical ventilation section
  6.9 Test specimen and calibration plate
7 Test methods
  7.1 Water penetration test
  7.2 Discharge and entry loss coefficient/pressure loss
8 Classification of weather louvers
  8.1 General
  8.2 Penetration classification
  8.3 Discharge and Entry loss coefficient
  8.4 Classification nomenclature
Annex A (normative) Simulated ran spray nozzles
Annex B (normative) Water eliminator performance test
  B.1 General
  B.2 Installation
  B.3 Procedure
Annex C (normative) Diagrams of apparatus and typical graphs
Annex D (informative) Typical calculation examples
  D.1 Test results
  D.2 Entry loss coefficient of entry
  D.3 Louvre effectiveness
  D.4 Classification

This European Standard specifies a method for measuring the water rejection performance of louvres subject to simulated rain and wind pressures, both with and without air flow through the louvre under test. For the purpose of tests in this standard, a 1000 mm ´ 1000 mm section of weather louvre or the nearest possible blade increment is considered.Weather louvres are designed to restrict the passage of water during rainfall while allowing the passage of air into or from an air distribution system or part of a building. They are used in a wide range of applications, where there may be differences in wind speed and direction, levels of local turbulence, rate and droplet size, distribution of rainfall and surface water flow from the surrounding structure. It is impractical to consider a standard test procedure simulating the whole range of likely conditions, but this standard provides for heavy rainfall directed on to the louvre surface, with simulated wind pressures. This provides a common basis on which to compare the water rejection performance of weather louvres of different designs. This standard is not intended for the evaluation of weather performance of pressure relief dampers.The purpose of tests incorporated in this European Standard is as follows:a) Weather testsTo establish the weather louvre effectiveness when subjected to wind pressure at various air flow rates.b) Discharge and Entry loss coefficient/Pressure requirementsTo establish the air pressure loss through the weather louvre at various air flow rates and by calculation the Discharge and Entry Loss Coefficient.

Committee
CEN/TC 156
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
SN EN 13030 : 2002 Identical
UNI EN 13030 : 2005 Identical
BS EN 13030:2001 Identical
I.S. EN 13030:2002 Identical
UNE-EN 13030:2003 Identical
DIN EN 13030:2002-03 Identical
NS EN 13030 : 1ED 2002 Identical
NF EN 13030 : 2002 Identical
PN EN 13030 : 2002 Identical
NBN EN 13030 : 2002 Identical
NEN EN 13030 : 2001 Identical

I.S. EN 13779:2007 VENTILATION FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS
UNI EN 15423 : 2008 VENTILATION FOR BUILDINGS - FIRE PRECAUTIONS FOR AIR DISTRIBUTION SYSTEMS IN BUILDINGS
PD CEN/TR 16798-4:2017 Energy performance of buildings. Ventilation for buildings Interpretation of the requirements in EN 16798-3. For non-residential buildings. Performance requirements for ventilation and room-conditioning systems(Modules M5-1, M5-4)
PREN 13053 : DRAFT 2017 VENTILATION FOR BUILDINGS - AIR HANDLING UNITS - RATING AND PERFORMANCE FOR UNITS, COMPONENTS AND SECTIONS
PD CEN/TS 16244:2018 Ventilation in hospitals. Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals
I.S. EN 13053:2006 VENTILATION FOR BUILDINGS - AIR HANDLING UNITS - RATING AND PERFORMANCE FOR UNITS, COMPONENTS AND SECTIONS
DIN EN 13053:2012-02 VENTILATION FOR BUILDINGS - AIR HANDLING UNITS - RATING AND PERFORMANCE FOR UNITS, COMPONENTS AND SECTIONS (INCLUDES AMENDMENT A1:2011)
BS EN 15423:2008 Ventilation for buildings. Fire precaution for air distribution systems in buildings
03/316891 DC : DRAFT OCT 2003 EN 13053 - VENTILATION FOR BUILDINGS - AIR HANDLING UNITS - RATINGS AND PERFORMANCE FOR UNITS, COMPONENTS AND SECTIONS
I.S. EN 15423:2008 VENTILATION FOR BUILDINGS - FIRE PRECAUTIONS FOR AIR DISTRIBUTION SYSTEMS IN BUILDINGS
BS EN 13053 : 2006 VENTILATION FOR BUILDINGS - AIR HANDLING UNITS - RATING AND PERFORMANCE FOR UNITS, COMPONENTS AND SECTIONS
UNI EN 13779 : 2008 VENTILATION FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS
CEN/TR 16798-4:2017 Energy performance of buildings - Ventilation for buildings - Part 4: Interpretation of the requirements in EN 16798- 3 - For non-residential buildings - Performance requirements for ventilation and room-conditioning systems(Modules M5-1, M5-4)
S.R. CEN/TS 16244:2018 VENTILATION IN HOSPITALS - COHERENT HIERARCHIC STRUCTURE AND COMMON TERMS AND DEFINITIONS FOR A STANDARD RELATED TO VENTILATION IN HOSPITALS
17/30339487 DC : 0 BS EN 13053 - VENTILATION FOR BUILDINGS - AIR HANDLING UNITS - RATING AND PERFORMANCE FOR UNITS, COMPONENTS AND SECTIONS
UNI EN 13053 : 2011 VENTILATION FOR BUILDINGS - AIR HANDLING UNITS - RATING AND PERFORMANCE FOR UNITS, COMPONENTS AND SECTIONS
BS EN 13779:2007 Ventilation for non-residential buildings. Performance requirements for ventilation and room-conditioning systems
EN 15423:2008 Ventilation for buildings - Fire precautions for air distribution systems in buildings
EN 13779:2007 Ventilation for non-residential buildings - Performance requirements for ventilation and room-conditioning systems
05/30128661 DC : 0 EN 13779 - VENTILATION FOR NON RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS
DIN EN 15423:2008-09 VENTILATION FOR BUILDINGS - FIRE PRECAUTIONS FOR AIR DISTRIBUTION SYSTEMS IN BUILDINGS
CEN/TS 16244:2018 Ventilation in hospitals - Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals
S.R. CEN/TR 16798-4:2017 ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 4: INTERPRETATION OF THE REQUIREMENTS IN EN 16798-3 - FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS (MODULES M5-1, M5-4)
EN 13053:2006+A1:2011 Ventilation for buildings - Air handling units - Rating and performance for units, components and sections
UNE-EN 13053:2007 Ventilation for buildings - Air handling units - Rating and performance for units, components and sections
DIN EN 13779:2007-09 VENTILATION FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS

ISO 5801:2017 Fans — Performance testing using standardized airways
EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
CR 12792 : 1997 VENTILATION FOR BUILDINGS - SYMBOLS AND TERMINOLOGY
ISO 5221:1984 Air distribution and air diffusion Rules to methods of measuring air flow rate in an air handling duct

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.