EN 13528-2:2002
Current
The latest, up-to-date edition.
Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods
25-09-2002
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Requirements
5.1 Desorption efficiency (for samplers involving solvent
desorption)
5.2 Desorption efficiency (for samplers involving thermal
desorption)
5.3 Effect of air velocity/sampler orientation
5.4 Storage (indirect-reading samplers)
5.5 Shelf life
5.6 Sampler integrity
5.7 Blank value
5.8 Field tests
5.9 Uncertainty
5.10 Instructions for use
5.11 Sample identification
6 General test conditions
6.1 Reagents
6.2 Apparatus
6.3 Independent method
6.4 Generation of calibration gas mixture
6.4.1 General
6.4.2 Calibration gas mixture
6.5 Test conditions
6.5.1 General
6.5.2 Laboratory tests under repeatability conditions
involving standard atmospheres (7.3, 7.4, 7,7,
7.8 and annex A)
6.5.3 Laboratory tests under reproducibility
conditions involving standard atmospheres (7.5)
6.5.4 Laboratory tests not involving standard
atmospheres (7.2, 7.6, 7.9)
6.5.5 Field tests
7 Test methods
7.1 General
7.2 Desorption efficiency
7.2.1 Spiking methods for samplers involving solvent
desorption
7.2.2 Spiking methods for samplers involving thermal
desorption
7.2.3 Phase equilibrium method (samplers involving
solvent desorption)
7.3 Bias due to the selection of non-ideal sorbent (for
samplers relying on reversible sorption)
7.3.1 Procedure
7.3.2 Calculation
7.4 Test on influence of air velocity and sampler
orientation
7.5 Effect of environmental parameters on sampler
performance (uptake rate)
7.5.1 Procedure
7.5.2 Calculation
7.6 Storage (for indirect-reading samplers)
7.6.1 Procedure
7.6.2 Calculation
7.7 Shelf life
7.8 Sampler leak test
7.9 Determination of the blank value
7.10 Field tests
8 Calculation of uncertainty
8.1 General
8.2 Desorption efficiency
8.3 Uptake rate
8.4 Storage
8.5 Shelf life
8.6 Sampler integrity
8.7 Blank value
8.8 Type B errors
8.9 Combined uncertainty
8.10 Field tests
9 Levels of evaluation
10 Test report
11 Marking
Annex A (normative) Determination of diffusive uptake
rates (indirect-reading samplers)
Annex B (normative) Calculation of exposure concentration
Annex C (informative) Calculation of uncertainty components
Bibliography
This part of the European Standard specifies specific performance requirements and test methods under prescribed laboratory and field conditions for diffusive samplers used for the determination of the concentration of gases or vapours in ambient air. Such requirements apply to all diffusive samplers, irrespective of the physical nature of the rate-controlling process and irrespective of the nature of the sorption process and the analytical determination.
Committee |
CEN/TC 264
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
GOST R EN 13528-2 : 2010 | Identical |
NS EN 13528-2 : 1ED 2002 | Identical |
UNI EN 13528-2 : 2003 | Identical |
UNE-EN 13528-2:2003 | Identical |
PN EN 13528-2 : 2004 | Identical |
NEN EN 13528-2 : 2002 | Identical |
SN EN 13528-2 : 2002 | Identical |
I.S. EN 13528-2:2002 | Identical |
NBN EN 13528-2 : 2002 | Identical |
NF EN 13528-2 : 2003 | Identical |
BS EN 13528-2:2002 | Identical |
DIN EN 13528-2:2002-12 | Identical |
03/306295 DC : DRAFT APR 2003 | EN 14662-4 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
I.S. EN 16339:2013 | AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING |
BS EN 13528-3:2003 | Ambient air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Requirements and test methods Guide to selection, use and maintenance |
BS EN 14662-4:2005 | Ambient air quality. Standard method for measurement of benzene concentrations Diffusive sampling followed by thermal desorption and gas chromatography |
EN 13528-3:2003 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance |
03/306296 DC : DRAFT APR 2003 | EN 14662-5 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 5: DIFFUSIVE SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY |
ISO 16000-4:2011 | Indoor air Part 4: Determination of formaldehyde Diffusive sampling method |
DIN EN ISO 16017-2:2003-09 | INDOOR, AMBIENT AND WORKPLACE AIR - SAMPLING AND ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY SORBENT TUBE/THERMAL DESORPTION/CAPILLARY GAS CHROMATOGRAPHY - PART 2: DIFFUSIVE SAMPLING |
ISO 16000-15:2008 | Indoor air — Part 15: Sampling strategy for nitrogen dioxide (NO2) |
DIN EN ISO 16000-15:2009-04 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
UNI EN ISO 16000-15 : 2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
DIN EN 16339:2013-11 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
BS EN ISO 16000-15:2008 | Indoor air Sampling strategy for nitrogen dioxide (NO2) |
06/30146336 DC : 0 | EN ISO 16000-15 - INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
UNE-EN 16339:2014 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
EN 14412:2004 | Indoor air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Guide for selection, use and maintenance |
EN ISO 16000-15:2008 | Indoor air - Part 15: Sampling strategy for nitrogen dioxide (NO2) (ISO 16000-15:2008) |
BS EN 16339:2013 | Ambient air. Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
I.S. EN ISO 16000-15:2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
BS EN 14662-5:2005 | Ambient air quality. Standard method for measurement of benzene concentrations Diffusive sampling followed by solvent desorption and gas chromatography |
BS EN ISO 16017-2:2003 | Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Diffusive sampling |
BS EN 14412:2004 | Indoor air quality. Diffusive samplers the determination of concentrations of gases and vapours. Guide for selection, use and maintenance |
EN 14662-4:2005 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 4: Diffusive sampling followed by thermal desorption and gas chromatography |
EN ISO 16017-2:2003 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003) |
EN 14662-5:2005 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 5: Diffusive sampling followed by solvent desorption and gas chromatography |
EN 16339:2013 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
DIN ISO 16000-4:2012-11 | INDOOR AIR - PART 4: DETERMINATION OF FORMALDEHYDE - DIFFUSIVE SAMPLING METHOD (ISO 16000-4:2011) |
UNI EN 16339 : 2013 | AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING |
NF ISO 16000-4 : 2012 | INDOOR AIR - PART 4: DETERMINATION OF FORMALDEHYDE - DIFFUSIVE SAMPLING METHOD |
BS ISO 16000-4:2011 | Indoor air Determination of formaldehyde. Diffusive sampling method |
ISO 16017-2:2003 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling |
DIN EN 14662-4:2005-08 | AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
DIN EN 13528-3:2004-04 | Ambient air quality - Diffuse samplers for the determination of concentrations of gases and vapours - Part 3: Guide to selection, use and maintenance |
DIN EN 14662-5:2005-08 | AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 5: DIFFUSIVE SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY |
DIN EN 14412:2004-12 | INDOOR AIR QUALITY - DIFFUSIVE SAMPLERS FOR THE DETERMINATION OF CONCENTRATIONS OF GASES AND VAPOURS - GUIDE FOR SELECTION, USE AND MAINTENANCE |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
ISO 6143:2001 | Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures |
ISO 6142:2001 | Gas analysis Preparation of calibration gas mixtures Gravimetric method |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
ISO 5725:1986 | Precision of test methods Determination of repeatability and reproducibility for a standard test method by inter-laboratory tests |
ISO 6141:2015 | Gas analysis Contents of certificates for calibration gas mixtures |
CR 14377:2002 | Air quality - Approach to uncertainty estimation for ambient air reference measurement methods |
ISO 3534-1:2006 | Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.