1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Measurement objectives and strategy
5.1 Measurements in support of Community Policy
5.1.1 Air Quality Directives
5.1.2 Source-related assessment
5.1.3 Forest Protection directives
5.1.4 Protection of ecosystems
5.1.5 Public awareness
5.2 Measurement in support of other policies
5.2.1 Measurement in support of national, regional or
local policies
5.2.2 Protection of special ecosystems
5.2.3 Particular research aspects
5.3 Measurement strategy
6 Selection of the device
6.1 Sources of information
6.2 Selection of a sampler and procedure
6.3 Specific applications
6.4 Compliance with parts 1 and 2 of this standard
7 Operating principles
7.1 Principles of diffusive sampling
7.2 Dimensions of diffusive uptake rate
7.3 Bias due to the selection of a non-ideal sorbent
7.4 Environmental factors affecting sampler performance
7.4.1 Temperature and pressure
7.4.2 Humidity
7.4.3 Transients
7.4.4 Influence of air velocity
7.4.5 Transportation
8 Protection from adverse environmental conditions
8.1 General
8.2 Air velocity
8.3 Precipitation
8.4 Provision of a shelter
8.5 Security
9 Arrangement of sampling points
10 Requirements for training
11 Quality assurance
Annex A (informative) - Specific applications
A.1 General
A.2 Nitrogen oxides
A.2.1 Tube-type samplers
A.2.2 US Environmental Protection Agency (EPA)/Monsanto
badge
A.3 Nitrogen monoxide
A.4 Sulphur dioxide
A.5 Ammonia
A.6 Organic gases (Volatile Organic Compounds or VOCs)
A.6.1 Tube-type samplers
A.6.2 Badge-type samplers
A.6.3 Radial samplers
A.7 Formaldehyde
A.8 Ozone
A.9 Shelters
A.10 Design of Standard Atmosphere Apparatus
Annex B (informative) - Characteristics of some diffusive samplers
Bibliography
This part of the European Standard gives guidance on the selection, use and maintenance of diffusive samplers used to measure ambient air quality.
Committee |
CEN/TC 264
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-EN 13528-3:2004 | Identical |
UNI EN 13528-3 : 2004 | Identical |
PN EN 13528-3 : 2005 | Identical |
SN EN 13528-3 : 2004 | Identical |
NBN EN 13528-3 : 2004 | Identical |
NS EN 13528-3 : 1ED 2004 | Identical |
BS EN 13528-3:2003 | Identical |
NEN EN 13528-3 : 2004 | Identical |
I.S. EN 13528-3:2004 | Identical |
GOST R EN 13528-3 : 2010 | Identical |
NF EN 13528-3 : 2004 | Identical |
DIN EN 13528-3:2004-04 | Identical |
03/306295 DC : DRAFT APR 2003 | EN 14662-4 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
I.S. EN 16339:2013 | AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING |
BS EN 14662-4:2005 | Ambient air quality. Standard method for measurement of benzene concentrations Diffusive sampling followed by thermal desorption and gas chromatography |
I.S. EN 838:2010 | WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS |
03/306296 DC : DRAFT APR 2003 | EN 14662-5 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 5: DIFFUSIVE SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY |
ISO 16000-15:2008 | Indoor air — Part 15: Sampling strategy for nitrogen dioxide (NO2) |
DIN EN ISO 16000-15:2009-04 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
UNI EN 838 : 2010 | WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS |
VDI 3869 Blatt 4:2012-03 | Measurement of ammonia in ambient air - Sampling with diffusive samplers - Photometric or ion chromatographic analysis |
VDI 3787 Blatt 10:2010-03 | Environmental meteorology - Human biometeorological requirements in the framework of recreation, prevention, therapy, and rehabilitation |
VDI 2119:2013-06 | Ambient air measurements - Sampling of atmospheric particles > 2,5 ?m on an acceptor surface using the Sigma-2 passive sampler - Characterisation by optical microscopy and calculation of number settling rate and mass concentration |
UNI EN ISO 16000-15 : 2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
DIN EN 16339:2013-11 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
08/30172873 DC : DRAFT JULY 2008 | BS EN 838 - WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS |
BS EN ISO 16000-15:2008 | Indoor air Sampling strategy for nitrogen dioxide (NO2) |
06/30146336 DC : 0 | EN ISO 16000-15 - INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
UNE-EN 16339:2014 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
BS EN 14662-1:2005 | Ambient air quality. Standard method for measurement of benzene concentrations Pumped sampling followed by thermal desorption and gas chromatography |
EN 14412:2004 | Indoor air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Guide for selection, use and maintenance |
EN ISO 16000-15:2008 | Indoor air - Part 15: Sampling strategy for nitrogen dioxide (NO2) (ISO 16000-15:2008) |
BS EN 16339:2013 | Ambient air. Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
DIN EN 838:2010-05 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
BS EN 14662-5:2005 | Ambient air quality. Standard method for measurement of benzene concentrations Diffusive sampling followed by solvent desorption and gas chromatography |
BS EN 838:2010 | Workplace exposure. Procedures for measuring gases and vapours using diffusive samplers. Requirements and test methods |
BS EN 14412:2004 | Indoor air quality. Diffusive samplers the determination of concentrations of gases and vapours. Guide for selection, use and maintenance |
BS EN 14662-2:2005 | Ambient air quality. Standard method for measurement of benzene concentrations Pumped sampling followed by solvent desorption and gas chromatography |
EN 14662-4:2005 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 4: Diffusive sampling followed by thermal desorption and gas chromatography |
EN 14662-5:2005 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 5: Diffusive sampling followed by solvent desorption and gas chromatography |
EN 14662-2:2005 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 2 : Pumped sampling followed by solvent desorption and gas chromatography |
EN 16339:2013 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
EN 14662-1:2005 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 1 : Pumped sampling followed by thermal desorption and gas chromatography |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
I.S. EN ISO 16000-15:2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
UNI EN 16339 : 2013 | AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING |
DIN EN 14662-4:2005-08 | AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
DIN EN 14662-1:2005-08 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 1: Pumped sampling followed by thermal desorption and gas chromatography |
DIN EN 14662-5:2005-08 | AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 5: DIFFUSIVE SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY |
DIN EN 14662-2:2005-08 | AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 2:PUMPED SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY |
DIN EN 14412:2004-12 | INDOOR AIR QUALITY - DIFFUSIVE SAMPLERS FOR THE DETERMINATION OF CONCENTRATIONS OF GASES AND VAPOURS - GUIDE FOR SELECTION, USE AND MAINTENANCE |
NS-EN 14662-1:2023 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 1: Pumped sampling followed by thermal desorption and gas chromatography |
I.S. EN 14662-1:2005 | AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 1: PUMPED SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
VDI 3490 Blatt 6:1988-12 | Measurement of gases; calibration gas mixtures; dynamic; preparation by gas-mixing pumps |
VDI 3490 Blatt 2:1980-12 | Measurement of gases; calibration gas mixtures; preparation methods; general |
ISO 6144:2003 | Gas analysis — Preparation of calibration gas mixtures — Static volumetric method |
VDI 3490 Blatt 11:1980-12 | Measurement of gases; preparation of calibration gas mixtures using plastic bags |
VDI 2119 Blatt 4:1997-08 | Measurement of Particulate Precipitations - Microscopic differentiation and size fractionated determination of particle deposition on adhesive collection plates - Sigma-2 sampler |
VDI 3490 Blatt 10:1981-01 | Measurement of gases; calibration gas mixtures; preparation of calibration gas mixtures using capillary device |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
ISO 6145-7:2009 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 7: Thermal mass-flow controllers |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
VDI 3490 Blatt 4:1980-12 | Measurement of gases; preparation of calibration gas mixtures by gravimetric methods |
ISO 6349:1979 | Gas analysis Preparation of calibration gas mixtures Permeation method |
ISO 16017-2:2003 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling |
VDI 3490 Blatt 9:1980-12 | Measurement of gases; preparation of calibration gas mixtures by permeation procedures |
ISO 6143:2001 | Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures |
VDI 3490 Blatt 14:1994-11 | Measurement of gases - Calibration gas mixtures - Preparation of calibration gas mixtures by volumetric static method using glass vessels |
EN ISO 16017-2:2003 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003) |
EN 13528-1:2002 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements |
ISO 6142:2001 | Gas analysis Preparation of calibration gas mixtures Gravimetric method |
ISO 6145-10:2002 | Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 10: Permeation method |
ISO 6145-2:2014 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 2: Piston pumps |
EN 13528-2:2002 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods |
VDI 3490 Blatt 16:1994-10 | Measurement of gases - Calibration gas mixtures - Dynamic preparation with critical orifice systems |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
ISO 5725:1986 | Precision of test methods Determination of repeatability and reproducibility for a standard test method by inter-laboratory tests |
VDI 3490 Blatt 8:1981-01 | Measurement of gases; calibration gas mixtures; preparation by continuous injection method |
ISO 6145-5:2009 | Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 5: Capillary calibration devices |
ISO 6145-4:2004 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method |
VDI 3490 Blatt 1:1980-12 | Measurement of gases; calibration gas mixtures; terms and legends |
ISO 6145-3:1986 | Gas analysis Preparation of calibration gas mixtures Dynamic volumetric methods Part 3: Periodic injections into a flowing gas stream |
ISO 6145-9:2009 | Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 9: Saturation method |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
ISO 6141:2015 | Gas analysis Contents of certificates for calibration gas mixtures |
VDI 3490 Blatt 15:1985-11 (Draft) | Measurement of gases; calibration gas mixtures; determination of the composition by gas density measuring technique; gas density balance |
VDI 3490 Blatt 3:1980-12 | Measurement of gases; specifications for transfer of calibration gas mixtures |
VDI 3490 Blatt 12:1988-12 | Measurement of gases; calibration gas mixtures; preparation of calibration gas mixtures by manometric methods |
VDI 3490 Blatt 17:1998-08 | Measurement of gases - Calibration gas mixtures - Dynamic preparation with thermal mass flow controllers |
ISO 6145-6:2017 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices |
VDI 3490 Blatt 5:1980-12 | Measurement of gases; determination of the composition of calibration gas mixtures by comparison methods |
VDI 3490 Blatt 13:1992-02 | Measurement of gases; calibration gas mixtures; preparation of calibration gas mixtures by saturation methods |
VDI 3490 Blatt 7:1980-12 | Measurement of gases; calibration gas mixtures; dynamic method of preparation by periodic injection |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.