Thermal insulation products for building equipment and industrial installations - Factory made phenolic foam (PF) products - Specification
09-12-2015
European foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols, units and abbreviated terms
4 Requirements
5 Test methods
6 Designation code
7 Assessment and Verification of the Constancy of
Performance (AVCP)
8 Marking and labelling
Annex A (normative) - Factory production control
Annex B (normative) - Determination of the aged value
of thermal conductivity
Annex C (normative) - Determination of minimum service
temperature
Annex D (informative) - Additional properties
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Regulation
Bibliography
This European Standard specifies the requirements for factory made phenolic foam products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature in the range of approximately - 200 °C to + 120 °C.Below an operating temperature of - 50 °C, special tests regarding the suitability of the products in the intended application are advised (e.g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases.The products are manufactured in the form of blocks, faced or unfaced, boards, pipe sections, segments and prefabricated ware.This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender.Products with a declared thermal conductivity greater than 0,050 W/(m·K) at 10 °C are not covered by this standard.This European Standard does not cover products for in situ-insulation (blowing or pouring) or products for the insulation of the building structure.This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.
Committee |
CEN/TC 88
|
DevelopmentNote |
Supersedes PREN 14314. (01/2016)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PN EN 14314 : 2016 | Identical |
NEN EN 14314 : 2015 | Identical |
SN EN 14314 : 2015 | Identical |
UNI EN 14314:2016 | Identical |
NBN EN 14314 : 2016 | Identical |
DIN EN 14314:2016-03 | Identical |
SS-EN 14314:2015 | Identical |
NS EN 14314 : 2015 | Identical |
BS EN 14314:2015 | Identical |
NF EN 14314 : 2016 | Identical |
I.S. EN 14314:2015 | Identical |
UNE-EN 14314:2015 | Identical |
PNE-EN 14314 | Identical |
BS EN 15715:2009 | Thermal insulation products. Instructions for mounting and fixing for reaction to fire testing. Factory made products |
07/30167661 DC : DRAFT AUG 2007 | BS EN 15715 - THERMAL INSULATION PRODUCTS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR REACTION TO FIRE TESTING - FACTORY MADE PRODUCTS |
I.S. EN 15715:2009 | THERMAL INSULATION PRODUCTS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR REACTION TO FIRE TESTING - FACTORY MADE PRODUCTS |
UNE-EN 16783:2017 | Thermal insulation products - Product category rules (PCR) for factory made and in-situ formed products for preparing environmental product declarations |
I.S. EN 16783:2017 | THERMAL INSULATION PRODUCTS - PRODUCT CATEGORY RULES (PCR) FOR FACTORY MADE AND IN-SITU FORMED PRODUCTS FOR PREPARING ENVIRONMENTAL PRODUCT DECLARATIONS |
EN 13166:2012+A2:2016 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
BS EN 16783:2017 | Thermal insulation products. Product category rules (PCR) for factory made and in-situ formed products for preparing environmental product declarations |
UNI EN 15715 : 2009 | THERMAL INSULATION PRODUCTS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR REACTION TO FIRE TESTING - FACTORY MADE PRODUCTS |
DIN EN 13166:2016-09 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
I.S. EN 13166:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
VDI 2055 Blatt 2:2013-10 | Thermal insulation of heated and refrigerated operational installations in the industry and in the building services - Technical basics for the verification of properties of insulating materials |
14/30301580 DC : 0 | BS EN/TC 16783 - THERMAL INSULATION PRODUCTS - PRODUCT CATEGORY RULES (PCR) FOR FACTORY MADE AND IN-SITU FORMED PRODUCTS FOR PREPARING ENVIRONMENTAL PRODUCT DECLARATIONS |
DIN EN 15715:2010-04 | Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products |
UNE-EN 15715:2012 | Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products |
UNE-EN 13166:2013 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
BS EN 13166 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
EN 16783:2017 | Thermal insulation products - Product category rules (PCR) for factory made and in-situ formed products for preparing environmental product declarations |
EN 15715:2009 | Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products |
ISO 9229:2007 | Thermal insulation Vocabulary |
EN 12667:2001 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance |
ISO 13787:2003 | Thermal insulation products for building equipment and industrial installations Determination of declared thermal conductivity |
EN 14706:2012 | Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature |
EN 12085:2013 | Thermal insulating products for building applications - Determination of linear dimensions of test specimens |
EN 14509:2013 | Self-supporting double skin metal faced insulating panels - Factory made products - Specifications |
EN 13468:2001 | Thermal insulating products for building equipment and industrial installations - Determination of trace quantities of water soluble chloride, fluoride, silicate, sodium ions and pH |
EN 1607:2013 | Thermal insulating products for building applications - Determination of tensile strength perpendicular to faces |
EN 1606:2013 | Thermal insulating products for building applications - Determination of compressive creep |
EN 1608:2013 | Thermal insulating products for building applications - Determination of tensile strength parallel to faces |
EN 13471:2001 | Thermal insulating products for building equipment and industrial installations - Determination of the coefficient of thermal expansion |
EN 12939:2000 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Thick products of high and medium thermal resistance |
EN ISO 8497:1996 | Thermal insulation - Determination of steady-state thermal transmission properties of thermal insulation for circular pipes (ISO 8497:1994) |
EN ISO 9229:2007 | Thermal insulation - Vocabulary (ISO 9229:2007) |
EN ISO 4590:2016 | Rigid cellular plastics - Determination of the volume percentage of open cells and of closed cells (ISO 4590:2016) |
EN 13469:2012 | Thermal insulating products for building equipment and industrial installations - Determination of water vapour transmission properties of preformed pipe insulation |
EN 824:2013 | Thermal insulating products for building applications - Determination of squareness |
ISO 11925-2:2010 | Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test |
EN 825:2013 | Thermal insulating products for building applications - Determination of flatness |
EN 823:2013 | Thermal insulating products for building applications - Determination of thickness |
ISO 8497:1994 | Thermal insulation — Determination of steady-state thermal transmission properties of thermal insulation for circular pipes |
EN ISO 13787:2003 | Thermal insulation products for building equipment and industrial installations - Determination of declared thermal conductivity (ISO 13787:2003) |
EN 13166:2012+A2:2016 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
EN 13470:2001 | Thermal insulating products for building equipment and industrial installations - Determination of the apparent density of preformed pipe insulation |
EN 13238:2010 | Reaction to fire tests for building products - Conditioning procedures and general rules for selection of substrates |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN 1602:2013 | Thermal insulating products for building applications - Determination of the apparent density |
EN 12090:2013 | Thermal insulating products for building applications - Determination of shear behaviour |
EN 1604:2013 | Thermal insulating products for building applications - Determination of dimensional stability under specified temperature and humidity conditions |
EN 14707:2012 | Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation |
EN 12089:2013 | Thermal insulating products for building applications - Determination of bending behaviour |
ISO 10456:2007 | Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values |
ISO 65:1981 | Carbon steel tubes suitable for screwing in accordance with ISO 7-1 |
EN 12429:1998 | Thermal insulating products for building applications - Conditioning to moisture equilibrium under specified temperature and humidity conditions |
EN 1609:2013 | Thermal insulating products for building applications - Determination of short term water absorption by partial immersion |
EN 826:2013 | Thermal insulating products for building applications - Determination of compression behaviour |
EN 15715:2009 | Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products |
EN 12086:2013 | Thermal insulating products for building applications - Determination of water vapour transmission properties |
EN 13172:2012 | Thermal insulation products - Evaluation of conformity |
EN 822:2013 | Thermal insulating products for building applications - Determination of length and width |