EN 14394:2005+A1:2008
Current
The latest, up-to-date edition.
Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C
06-08-2008
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Materials
6 Design
7 Tests
8 Performance requirements
9 Technical documentation
Annex A (normative) Cylindrical shells under internal
pressure
Annex B (normative) Spherical shells and dished heads
under internal and external pressure
Annex C (normative) Dished fire tube heads
Annex D (normative) Flat walls, stayings and girder stays
Annex E (normative) Cylindrical shells under external
pressure
Annex F (informative) Pressure Equipment Directive 97/23/EC
Annex ZA (informative) Relationship between this European
Standard and the Essential Requirements of EU
Directive 92/42/EEC of 21 May 1992 on efficiency
requirements for new hot-water boilers
fired with liquid or gaseous fuels
Annex ZB (informative) Relationship between this European Standard
and the Essential Requirements of EU Directive 97/23/EC
concerning pressure equipment (PED)
Bibliography
This European Standard specifies the requirements and test methods for the design, manufacturing, safe operation and the rational energy usage for standard boilers and low temperature boilers (with "boiler" in the sense of "boiler body") from steel and cast iron to be equipped with separately marketed forced draught burners according to the relevant burner standards (for automatic forced draught burners for gaseous fuels see EN 676 and for atomising oil burners see EN 267) up to a nominal heat output of 10 MW. They are operated, either with negative pressure (natural draught boiler) or with positive pressure (pressurised boiler) in the combustion chamber, in accordance with the boiler manufacturer's instructions."This European Standard specifies requirements for boilers with normal operating temperatures between 100 °C and 110 °C and has a "dual structure":-For boilers where the shut off temperature of the safety temperature limiter does not exceed 110 °C the Pressure Equipment Directive (PED) requires" Sound Engineering Practice", -For boilers where the shut off temperature of the safety temperature limiter exceeds 110 °C this European Standard specifies the requirements of the PED as stated in Annex ZB.NOTE 1The "maximum allowable temperature TS" is defined in the PED and its Guidelines."Boilers in accordance with this European Standard are designed for the heating of central heating installations in which the heat carrier is water, and the maximum allowable operating temperature of which is up to 110 C and the maximum safety temperature limiter of 120 C. The maximum allowable operating pressure is 10 bar.This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, oil or gas fired condensation boilers, boilers with oil vaporisation burners. For these boilers there are further requirements.For gas-fired central heating boilers equipped with a forced draught burner of nominal heat out put not exceeding 1000 kW,
| Committee |
CEN/TC 57
|
| DevelopmentNote |
2005 Edition Re-Issued in August 2008 & incorporates AMD 1 2008. (08/2008)
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Current
|
| Standards | Relationship |
| NBN EN 14394 : 2006 + A1 2009 | Identical |
| NEN EN 14394 : 2005 + A1 2008 | Identical |
| NS EN 14394 : 2005 + A1 2008 | Identical |
| I.S. EN 14394:2006 | Identical |
| PN EN 14394 : 2006 + A1 2010 | Identical |
| BS EN 14394 : 2005 | Identical |
| NF EN 14394 : 2006 + A1 2008 | Identical |
| DIN EN 14394:2008-12 | Identical |
| BS EN 14394:2005+A1:2008 | Equivalent |
| I.S. EN 14394:2005+A1:2008 | Equivalent |
| UNE-EN 14394:2006 | Identical |
| UNE-EN 14394:2006+A1:2009 | Identical |
| BS EN 14394:2005+A1:2008 | Identical |