• EN 14793:2017

    Current The latest, up-to-date edition.

    Stationary source emissions - Demonstration of equivalence of an alternative method with a reference method

    Available format(s): 

    Language(s): 

    Published date:  10-01-2017

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols
    5 Contents of the demonstration of equivalence
    6 Report of the demonstration of equivalence
    Annex A (informative) - Example of comparison of repeatability and
            trueness of Thorin Method and Ion Chromatography Method
            for SO[2] measurement in stack
    Annex B (informative) - Critical values for Grubbs test
    Annex C (normative) - Minimum requirements for a test bench
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard specifies a procedure to demonstrate the equivalence of an alternative method (AM) with the reference method (RM) or the standard reference method (SRM), both implemented to determine the same measurand. In particular, this European Standard provides the statistical tools and different criteria to evaluate the alternative method. This does not release the body performing the equivalence testing from bearing technical and analytical judgement on the evaluation of the different criteria.Three steps are required for demonstration of equivalence:description of the alternative method and setting of the field of application (measurement range and type of gas matrix);determination of the performance characteristics of the alternative method and calculation of the expanded uncertainty where appropriate and check of compliance with the maximum expanded uncertainty allowed for the reference method;check of repeatability and lack of systematic deviation of the alternative method in the field or on a recognized test bench in comparison with the reference method for the type of matrix defined in the field of equivalence.This European Standard requires that a reference method has been defined and validated.This European Standard only considers the case of linear quantitative methods.This European Standard has been drawn up for laboratories working in air quality measurements and consequently an example taken from this sector are presented in Annex A.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 264
    Development Note Supersedes PREN 14793 & CEN/TS 14793. (01/2017)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-EN 15058:2017 Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
    UNE-EN 14789:2017 Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
    DIN EN 14790:2006-04 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD
    BS EN 14791:2017 Stationary source emissions. Determination of mass concentration of sulphur oxides. Standard reference method
    CEN/TS 17021:2017 Stationary source emissions - Determination of the mass concentration of sulphur dioxide by instrumental techniques
    DIN EN 14789:2017-05 STATIONARY SOURCE EMISSIONS - DETERMINATION OF VOLUME CONCENTRATION OF OXYGEN - STANDARD REFERENCE METHOD: PARAMAGNETISM
    DIN EN 15267-4:2015-08 (Draft) AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 4: PERFORMANCE CRITERIA AND TEST PROCEDURES FOR AUTOMATED MEASURING SYSTEMS FOR PERIODIC MEASUREMENTS OF EMISSIONS FROM STATIONARY SOURCES
    PD CEN/TS 17021:2017 Stationary source emissions. Determination of the mass concentration of sulphur dioxide by instrumental techniques
    UNE-EN 15267-4:2018 Air quality - Certification of automated measuring systems - Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources
    DIN EN 14789:2006-04 STATIONARY SOURCE EMISSIONS - DETERMINATION OF VOLUME CONCENTRATION OF OXYGEN - STANDARD REFERENCE METHOD: PARAMAGNETISM
    BS EN 14792:2017 Stationary source emissions. Determination of mass concentration of nitrogen oxides. Standard reference method. Chemiluminescence
    I.S. EN 14792:2017 STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF NITROGEN OXIDES - STANDARD REFERENCE METHOD: CHEMILUMINESCENCE
    I.S. EN 14791:2017 STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF SULPHUR OXIDES - STANDARD REFERENCE METHOD
    I.S. EN 14789:2017 STATIONARY SOURCE EMISSIONS - DETERMINATION OF VOLUME CONCENTRATION OF OXYGEN - STANDARD REFERENCE METHOD: PARAMAGNETISM
    I.S. EN 14790:2017 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD
    I.S. EN 15058:2017 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF CARBON MONOXIDE - STANDARD REFERENCE METHOD: NON-DISPERSIVE INFRARED SPECTROMETRY
    VDI 3469 Blatt 1:2016-09 Emission control - Production and processing of fibrous materials - Fibrous dusts; Fundamentals, overview
    BS EN 15267-4:2017 Air quality. Certification of automated measuring systems Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources
    I.S. EN 15267-4:2017 AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 4: PERFORMANCE CRITERIA AND TEST PROCEDURES FOR AUTOMATED MEASURING SYSTEMS FOR PERIODIC MEASUREMENTS OF EMISSIONS FROM STATIONARY SOURCES
    I.S. CEN/TS 17021:2017 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF SULPHUR DIOXIDE BY INSTRUMENTAL TECHNIQUES
    DIN EN 14792 E : 2006 STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF NITROGEN OXIDES - STANDARD REFERENCE METHOD: CHEMILUMINESCENCE
    UNE-EN 14791:2017 Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
    DIN EN 14792:2006-04 STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF NITROGEN OXIDES - STANDARD REFERENCE METHOD: CHEMILUMINESCENCE
    DIN EN 15058 E : 2006 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF CARBON MONOXIDE - STANDARD REFERENCE METHOD: NON-DISPERSIVE INFRARED SPECTROMETRY
    DIN EN 14791 E : 2006 STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF SULPHUR OXIDES - STANDARD REFERENCE METHOD
    DIN EN 14789 E : 2017 STATIONARY SOURCE EMISSIONS - DETERMINATION OF VOLUME CONCENTRATION OF OXYGEN - STANDARD REFERENCE METHOD: PARAMAGNETISM
    BS EN 14789:2017 Stationary source emissions. Determination of volume concentration of oxygen. Standard reference method: Paramagnetism
    UNE-EN 14792:2017 Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
    UNE-EN 14790:2017 Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
    DIN EN 15058:2006-09 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF CARBON MONOXIDE - STANDARD REFERENCE METHOD: NON-DISPERSIVE INFRARED SPECTROMETRY
    BS EN 14790:2005 Stationary source emissions. Determination of the water vapour in ducts
    DIN EN 14791:2006-04 STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF SULPHUR OXIDES - STANDARD REFERENCE METHOD
    EN 14790:2017 Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
    EN 14789:2017 Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
    EN 15058:2017 Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
    EN 14791:2017 Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
    EN 15267-4:2017 Air quality - Certification of automated measuring systems - Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources
    EN 14792:2017 Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
    DIN EN 14790 E : 2017 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD
    BS EN 15058:2017 Stationary source emissions. Determination of the mass concentration of carbon monoxide. Standard reference method: non-dispersive infrared spectrometry
    DIN EN 14790:2017-05 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
    ISO 11843-1:1997 Capability of detection Part 1: Terms and definitions
    EN ISO/IEC 17043:2010 Conformity assessment - General requirements for proficiency testing (ISO/IEC 17043:2010)
    ISO 14956:2002 Air quality Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
    ISO 11095:1996 Linear calibration using reference materials
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    ISO/IEC 17043:2010 Conformity assessment — General requirements for proficiency testing
    EN ISO 14956 : 2002 AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY
    ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
    EN 15267-4:2017 Air quality - Certification of automated measuring systems - Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective