EN 14908-2:2014
Current
The latest, up-to-date edition.
Open Data Communication in Building Automation, Controls and Building Management - Control Network Protocol - Part 2: Twisted Pair Communication
30-04-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Network overview
4 System specifications
5 Link power
6 Node specifications
7 Communication parameters
Annex A (informative) - Environmental specifications
Bibliography
This European Standard specifies the control network protocol (CNP) free-topology twisted-pair channel for networked control systems in commercial Building Automation, Controls and Building Management and is used in conjunction with EN 14908-1:2014. The channel supports communication at 78,125 kbit/s between multiple nodes, each of which consists of a transceiver, a protocol processor, an application processor, a power supply, and application electronics.This European Standard covers the complete physical layer (OSI Layer 1), including the interface to the Media Access Control (MAC) sub-layer and the interface to the medium. Parameters that are controlled by other layers but control the operation of the physical layer are also specified.
Committee |
CEN/TC 247
|
DevelopmentNote |
Together with EN 13321-1 and EN 14908-1 Supersedes ENV 13154-2. (11/2005) To be read in conjunction with EN 14908-1. Supersedes PREN 14908-2. (05/2014) Supersedes UNE EN 14908-2. (06/2014)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
I.S. EN 14908-2:2014 | Identical |
UNI EN 14908-2 : 2014 | Identical |
UNE-EN 14908-2:2014 | Identical |
DIN EN 14908-2:2014-08 | Identical |
PN EN 14908-2 : 2014 | Identical |
BS EN 14908-2:2014 | Identical |
NBN EN 14908-2 : 2014 | Identical |
NF EN 14908-2 : 2014 | Identical |
NEN EN 14908-2 : 2014 | Identical |
NS EN 14908-2 : 2014 | Identical |
SN EN 14908-2 : 2014 | Identical |
UNE-EN 14908-2:2006 | Identical |
PNE-FprEN 14908-2 | Identical |
BS EN 14908-5:2009 | Open data communication in building automation, controls and building management implementation guideline. Control network protocol Implementation |
09/30186912 DC : DRAFT MAR 2009 | BS EN 14908-6 - OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - CONTROL NETWORK PROTOCOL - PART 6: APPLICATION ELEMENTS |
I.S. EN 14908-5:2009 | OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT IMPLEMENTATION GUIDELINE - CONTROL NETWORK PROTOCOL - PART 5: IMPLEMENTATION |
PREN 14908-6 : DRAFT 2014 | OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - CONTROL NETWORK PROTOCOL - PART 6: APPLICATION ELEMENTS |
BS EN 14908-6:2014 | Open Data Communication in Building Automation, Controls and Building Management. Control Network Protocol Application elements |
UNI EN 14908-5 : 2009 | OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT IMPLEMENTATION GUIDELINE - CONTROL NETWORK PROTOCOL - PART 5: IMPLEMENTATION |
EN 14908-6:2014 | Open Data Communication in Building Automation, Controls and Building Management - Control Network Protocol - Part 6: Application elements |
EN 14908-5:2009 | Open Data Communication in Building Automation, Controls and Building Management Implementation Guideline - Control Network Protocol - Part 5: Implementation |
14/30294063 DC : 0 | BS EN 14908-6 - OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - CONTROL NETWORK PROTOCOL - PART 6: APPLICATION ELEMENTS |
06/30149065 DC : 0 | EN 14908-5 - OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT IMPLEMENTATION GUIDELINE - CONTROL NETWORK PROTOCOL - PART 5: IMPLEMENTATION GUIDELINE |
I.S. EN 14908-6:2014 | OPEN DATA COMMUNICATION IN BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - CONTROL NETWORK PROTOCOL - PART 6: APPLICATION ELEMENTS |
EN 14908-1:2014 | Open Data Communication in Building Automation, Controls and Building Management - Control Network Protocol - Part 1: Protocol Stack |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.