EN 16477-1:2016
Current
The latest, up-to-date edition.
Glass in building - Painted glass for internal use - Part 1: Requirements
07-12-2016
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Materials
5 Dimensional requirements
6 Quality requirements
7 Classification of painted glass
8 Testing of painted glass
Annex A (normative) - Condensation water test
in constant atmosphere
Annex B (normative) - Determination of the
[Delta] E[*]
Annex C (informative) - Fixing of painted glass and
cleaning after installation
Bibliography
This European Standard specifies minimum quality requirements (in respect of optical, visual and edge faults) and durability tests for painted glass for internal use in building.This standard applies to testing of paints that can be used to produce painted glass. The test of durability are undertaken on soda lime silicate glass as being a representative substrate. Painted glass, that conforms to this standard, may have substrate as follows: basic glass, special basic glass, chemically strengthened basic glass, thermally treated basic and special basic glass, laminated glass or laminated safety glass. The painted glass may be translucent, transparent or opaque and supplied in stock/standard sizes and as-cut finished sizes.NOTE 1Artistic products are excluded from the scope of this standard. For painted glass used in aggressive and/or constantly high humidity atmospheres, e.g. horse riding halls, swimming pools, medical baths, saunas, etc. this standard is not applicable. NOTE 2Bathrooms and kitchens are not considered as constantly high humidity atmospheres.This standard does not give requirements for framing, fixing or other support systems.NOTE 3Useful advice on these items is contained in the informative annex C.
Committee |
CEN/TC 129
|
DevelopmentNote |
Supersedes PREN 16477-1. (12/2016)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-EN 16477-1:2017 | Identical |
BS EN 16477-1:2016 | Identical |
NS EN 16477-1 : 2016 | Identical |
DIN EN 16477-1:2016-07 (Draft) | Identical |
SN EN 16477-1 : 2016 | Identical |
NEN EN 16477-1 : 2016 | Identical |
PN-EN 16477-1: 2017-01 | Identical |
NF EN 16477-1 : 2017 | Identical |
I.S. EN 16477-1:2016 | Identical |
UNI EN 16477-1 : 2017 | Identical |
DIN EN 16477-1:2017-07 | Identical |
PREN 14449 : DRAFT 2017 | GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - PRODUCT STANDARD |
17/30351893 DC : 0 | BS EN 17074 - GLASS IN BUILDING - ENVIRONMENTAL PRODUCT DECLARATION - PRODUCT CATEGORY RULES FOR FLAT GLASS PRODUCTS |
ISO 16474-2:2013 | Paints and varnishes — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
EN 12337-1:2000 | Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description |
EN 13024-1:2011 | Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description |
EN 1748-2-1:2004 | Glass in building - Special basic products - Glass ceramics - Part 2-1 Definitions and general physical and mechanical properties |
EN 14321-1:2005 | Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description |
EN 14179-1:2016 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN 12488:2016 | Glass in building - Glazing recommendations - Assembly principles for vertical and sloping glazing |
EN ISO 11664-4:2011 | Colorimetry - Part 4: CIE 1976 L*a*b* Colour space (ISO 11664-4:2008) |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
ISO 11664-4:2008 | Colorimetry Part 4: CIE 1976 L*a*b* Colour space |
EN 1863-1:2011 | Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description |
EN 14178-1:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass |
EN ISO 2409:2013 | Paints and varnishes - Cross-cut test (ISO 2409:2013) |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 12150-1:2015 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN 1748-1-1:2004 | Glass in building - Special basic products -Borosilicate glasses - Part 1-1: Definition and general physical and mechanical properties |
ISO 12543-1:2011 | Glass in building Laminated glass and laminated safety glass Part 1: Definitions and description of component parts |
EN 572-8:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 8: Supplied and final cut sizes |
EN 15682-1:2013 | Glass in building - Heat soaked thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description |
EN ISO 16474-2:2013 | Paints and varnishes - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (ISO 16474-2:2013) |
EN ISO 12543-1:2011 | Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:2011) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.