Foreword
1 Scope
2 Normative references
3 Definitions
4 Means of attachment of signs
5 Drain holes
6 Installation of the mains supply
7 Enclosures and protection of live parts
8 Protection against indirect contact
9 Transformers
10 Earth-leakage and open-circuit protection
11 Invertors and convertors
12 Auxiliaries
13 Insulating sleeves
14 Specification and installation of high-voltage cables
15 High-voltage connections
16 Supports for luminous-discharge tubes
17 Electromagnetic compatibility
18 Inspection and testing of installations
19 Marking and site records
Annex A (informative) List of high-voltage cables
specified in EN 50143
Annex B (normative) Special national conditions
Annex C (informative) A-deviations
This European Standard specifies the requirements and method of installation for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1000 V but not exceeding 10.000 V, including the electrical components and wiring. The standard covers installations used for publicity, decorative or general lighting purposes, either for external or internal use. Such signs or luminous-discharge-tube installations may be either fixer or portable supplied from a low-voltage (L.V.) or extra-low-voltage (E.L.V) source by means of a transformer, invertor or convertor. Note: although the requirements are not specified in this Standard, attention is drawn to the need for an effective maintenance programme to be carried out on all signs or luminous-discharge-tube installations. The inspection and testing requirements included in any maintenance programme should closely follow those specified in clause 18 of this Standard
Committee |
CLC/TC 34
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
CEI EN 50107 : 1ED 1999 | Identical |
I.S. EN 50107:1998 | Identical |
DIN EN 50107 : 1998 | Identical |
BS EN 50107:1998 | Identical |
SN EN 50107 : 1998 | Identical |
NEN EN 50107 : 1998 | Identical |
NBN EN 50107 : 1998 | Identical |
UNE-EN 50107:1999 | Identical |
VDE 0128 : 1998 | Identical |
NF EN 50107 : 1998 | Identical |
HD 384.7.711 : 200S1 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-711: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXHIBITIONS, SHOWS AND STANDS |
05/30138070 DC : DRAFT AUG 2005 | IEC 60598-2-27 ED 1 - LUMINARIES - PART 2-27: LUMINARIES FOR NEON LAMP AND SIMILAR EQUIPMENT |
07/30164212 DC : 0 | BS EN 50143 - CABLES FOR SIGNS AND LUMINOUS-DISCHARGE TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V |
I.S. HD 384.7.711:2003 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-711: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXHIBITIONS, SHOWS AND STANDS |
EN 61050:1992/A1:1995 | TRANSFORMERS FOR TUBULAR DISCHARGE LAMPS HAVING A NON LOAD OUTPUT VOLTAGE EXCEEDING 1000 V (GENERALLY CALLED NEON TRANSFORMERS - GENERAL AND SAFETY REQUIREMENTS |
EN 50143:2009 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 61547:2009 | Equipment for general lighting purposes - EMC immunity requirements |