• EN 50151 : 2003 COR 2010

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS

    Available format(s): 

    Superseded date:  01-02-2016

    Language(s): 

    Published date:  12-01-2013

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope
    2 Normative references
    3 Definitions
    4 Characteristics of insulators
       4.1 General
       4.2 Target life
       4.3 Purchaser requirements
       4.4 In-running contact insulators
       4.5 Electrical requirements
       4.6 Mechanical requirements
       4.7 Corrosion
       4.8 Fire safety
       4.9 Anti-vandalism
    5 Design, manufacture and workmanship
    6 Testing
       6.1 Design tests
       6.2 Type tests
       6.3 Sample tests
       6.4 Routine tests
    7 Verification of compliance
       7.1 Certification of compliance and test results
       7.2 Inspection and testing
       7.3 Test certificates
    8 Maintenance instructions
    9 Identification of the insulator
    10 Delivery and packaging
    Annex A (informative) Load time withstand curve
    Annex B (informative) Pendulum impact test
    Annex C (informative) Further reading list
    Annex ZZ (informative) Coverage of Essential Requirements
             of EC Directives
    Bibliography

    Abstract - (Show below) - (Hide below)

    Covers characteristics for composite insulators for use in electric traction overhead contact lines for railways and tramways, as defined in EN 50119.

    General Product Information - (Show below) - (Hide below)

    Committee TC 9X
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    NF EN 50119 : 2010 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
    EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
    ANSI C29.1 : 1988 TEST METHODS FOR ELECTRICAL POWER INSULATORS
    IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
    IEC 60754-1:2011 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
    EN 60707 : 1999 FLAMMABILITY OF SOLID NON-METALLIC MATERIALS WHEN EXPOSED TO FLAME SOURCES - LIST OF TEST METHODS
    IEC 61952:2008 Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
    IEC 60707:1999 Flammability of solid non-metallic materials when exposed to flame sources - List of test methods
    EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    IEC 60754-2:2011 Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
    EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
    HD 602 : 200S1 TEST ON GASES EVOLVED DURING COMBUSTION OF ELECTRIC CABLES - DETERMINATION OF DEGREE OF ACIDITY OF GASES EVOLVED DURING THE COMBUSTION OF MATERIALS TAKEN FROM ELECTRIC CABLES BY MEASURING PH CONDUCTIVITY
    EN 61952:2008 Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective