EN 50216-2 : 2002 AMD 1 2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
POWER TRANSFORMER AND REACTOR FITTINGS - PART 2: GAS AND OIL ACTUATED RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR
27-01-2022
12-01-2013
1 Scope
2 Normative references
3 Service conditions
3.1 Maximum inclination
3.2 Operating pressure
3.3 Sensitivity of the relay contacts to magnetic
fields
3.4 Special mechanical conditions
4 Dimensions
5 Operational performance
5.1 Alarm and trip contacts
5.2 Oil loss from tank
5.3 Latching of trip element
6 Electrical characteristics of switch
6.1 Switch type
6.2 Rated currents
6.3 Breaking and making capacity
7 Mechanical requirements
7.1 Terminal box
7.2 Testing facility
7.3 Gas sampling
7.4 Draining device
7.5 Presence of gas in the relay
7.6 Mounting arrangement
7.7 Pressure and vacuum
8 Nameplate
9 Tests
9.1 Routine tests
9.2 Type tests
Gives the gas and oil actuated relay (Buchholz relay) for liquid immersed power transformers and reactors with conservator for indoor or outdoor installation.
Committee |
TC 14
|
DevelopmentNote |
To be read in conjunction with EN 50216-1. (11/2003)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NBN EN 50216-2 : 2002 AMD 1 2003 | Identical |
NEN EN 50216-2 : 2002 AMD 1 2003 | Identical |
I.S. EN 50216-2:2002 | Identical |
PN EN 50216-2 : 2004 | Identical |
SN EN 50216-2 : 2002 AMD 1 2002 | Identical |
VDE 0532-216-2 : 2002 COR 1 2016 | Identical |
DIN EN 50216-2 : 2002 COR 1 2016 | Identical |
UNE-EN 50216-2/A1:2003 | Identical |
CEI EN 50216-2/A1:2003 | Identical |
UNE-EN 50216-2:2003 | Identical |
BS EN 50216-2:2002 | Identical |
NF EN 50216-2 : 2002 AMD 1 2003 | Identical |
CEI CLC/TS 50537-4 : 2011 | RAILWAY APPLICATIONS - MOUNTED PARTS OF THE TRACTION TRANSFORMER AND COOLING SYSTEM - PART 4: GAS AND LIQUID ACTUATED (BUCHHOLZ) RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR FOR RAIL VEHICLES |
CLC/TS 50537-4:2010 | Railway applications - Mounted parts of the traction transformer and cooling system - Part 4: Gas and liquid actuated (Buchholz) relay for liquid immersed transformers and reactors with conservator for rail vehicles |
DD CLC/TS 50537-4:2010 | Railway applications. Mounted parts of the traction transformer and cooling system Gas and liquid actuated (Buchholz) relay for liquid immersed transformers and reactors with conservator for rail vehicles |
S.R. CLC/TS 50537-4:2010 | RAILWAY APPLICATIONS - MOUNTED PARTS OF THE TRACTION TRANSFORMER AND COOLING SYSTEM - PART 4: GAS AND LIQUID ACTUATED (BUCHHOLZ) RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR FOR RAIL VEHICLES |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
EN 60068-3-3:1993 | Environmental testing - Part 3: Guidance - Seismic test methods for equipments |
EN 60255-5:2001 | Electrical relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60255-5:2000 | Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60721-3-4:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
EN 50216-1:2002 | Power transformer and reactor fittings - Part 1: General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.