• Shopping Cart
    There are no items in your cart

EN 50306-4:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed

Superseded date

26-03-2020

Superseded by

EN 50306-4:2020

Published date

31-10-2002

Sorry this product is not available in your region.

Introduction
1 Scope
2 Normative references
3 Multicore cables - sheathed
4 Tests
5 Multicore cables - screened and sheathed
6 Tests
7 Multipair cables - individually screened and
  sheathed and with an overall sheath
8 Tests
Annex A (informative) Guidance on selection of
        cables for type approval
Annex B (informative) Bibliography
Tables

EN 50306-4 specifies requirements for, and constructions and dimensions of, multicore and multipair cables rated 300 V to earth, of the following types:-unscreened, sheathed for either exposed or protected wiring(0,5 mm2 to 2,5 mm2, number of cores from 2 to 48);-screened, sheathed for either exposed or protected wiring(0,5 mm2 to 2,5 mm2, number of cores from 2 to 8);-screened, sheathed for either exposed or protected wiring(0,5 mm2 to 1,5 mm2, number of pairs of cores from 2 to 7).NOTE 1 Not all conductor sizes/number of cores are specified for every type.All cables have stranded tinned copper conductors, halogen-free, thin wall thickness insulation and standard wall thickness sheath. Cable types are specified for use in exposed situations (Class E), and for protected situations (Class P). They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at temperatures of 90 °C or 105 °C dependent upon the sheath system type.NOTE 2 In EN 50306-4 the higher temperature rating of 105 °C is only allowed where sheath type S2 is used, and where it has been specifically tested for the higher rating (i.e. by long-term thermal endurance testing to demonstrate a lifetime of at least 20 000 h at 125 °C).The maximum temperature for short-circuit conditions of 160 °C is based on a duration of 5 s.The cables specified in EN 50306-4 which have a sheath of type EM 101, EM 103 or S2 material are suitable for operation at temperatures as low as – 25 °C and those with sheath of type EM 102 or EM 104 material are suitable for operation at temperatures as low as 40 °C.NOTE 3 Where fuel oil is present sheath types EM 101 and EM 102 are not suitable.NOTE 4 S2 material may also be suitable for operational temperatures as low as –40 °C, but if so must be tested accordingly to confirm this.Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-1 ).NOTE 5 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1.NOTE 6 EN 45545-1 is still under development and should be consulted.EN 50306-4 should be used in conjunction with EN 50306-1, General requirements, EN 50306-2, Single core cables, and EN 50306-3, Single core and multicore cables.

Committee
CLC/TC 20
DevelopmentNote
To be used in conjunction with EN 50306-1. (01/2003)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

UNE-EN 50467:2012 Railway applications - Rolling stock - Electrical connectors, requirements and test methods
I.S. EN 50467:2011 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
CEI EN 50467 : 2013 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
PREN 50467 : DRAFT 2009 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
BS EN 50355:2013 Railway applications. Railway rolling stock cables having special fire performance. Guide to use
13/30277639 DC : 0 BS EN 50355 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
CEI EN 50355 : 2014 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
DD CLC/TS 50467:2008 Railway applications. Rolling stock. Electrical connectors, requirements and test methods
PREN 50355 : DRAFT 2012 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
12/30235292 DC : 0 BS EN 50343 - RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
S.R. CLC/TS 50467:2008 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
CLC/TS 50467 : 2008 COR 2008 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
09/30208429 DC : 0 BS EN 50467 - RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
BS EN 50467:2011 Railway applications. Rolling stock. Electrical connectors, requirements and test methods
I.S. EN 50355:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
IEC 62847:2016 Railway applications - Rolling stock - Electrical connectors - Requirements and test methods
EN 50467:2011 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS

EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
EN 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
EN 45545-1 : 2013 COR 2013 RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL
EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
EN 50268-2:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 2: Procedure
EN 50306-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.