EN 50397-2:2009
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteria
30-10-2009
01-05-2012
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Quality assurance
6 Classification of tests - Type tests, sample tests,
routine tests
7 Tests
Annex A (normative) - Type tests, sample tests and routine
tests
Annex B (informative) - Example of sampling with inspection
by attributes
Annex C (informative) - Example of sampling with inspection
by variable
Annex D (normative) - Special national conditions
Bibliography
Covered overhead line conductors are equipped with a plastic covering (XLPE-based) as protection against accidental contact with grounded parts respectively against accidental contact with other, at least covered live parts (e.g. other covered overhead line conductors) - This plastic cover is not a touch-proof, full protecting insulation - The covered overhead line conductors are designed for the use in high-voltage overhead lines with rated voltages up to 30 kV AC - The application of covered overhead line conductors is exclusively allowed on suitable insulators, which are designed for the rated voltage of the overhead line - As protection against negative influences by water penetration, the conductor may be equipped with measures to maintain longitudinal water tightness
| Committee |
CLC/TC 20
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Withdrawn
|
| Standards | Relationship |
| OVE/ONORM EN 50397-2 : 2010 | Identical |
| VDE 0276-397-2 : 2010 | Identical |
| NEN EN 50397-2 : 2009 | Identical |
| DIN EN 50397-2 : 2010 | Identical |
| NF EN 50397-2 : 2010 | Identical |
| BS EN 50397-2:2009 | Identical |
| PN EN 50397-2 : 2009 | Identical |
| NBN EN 50397-2 : 2010 | Identical |
| I.S. EN 50397-2:2009 | Identical |
| CEI EN 50397-2 : 2011 | Identical |
| BS EN 61915-1:2008 | Identical |
| UNE-EN 50397-2:2010 | Identical |
| EN 50397-3:2010 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 3: Guide to use |
| BS EN 50397-3:2010 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. Guide to use |
| 08/30182118 DC : DRAFT OCT 2008 | BS EN 50397-3 - COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE |
| CEI EN 50397-3 : 2011 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE |
| NF EN 50397-3 : 2010 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE |
| I.S. EN 50397-3:2010 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE |
| IEC 60826:2017 | Design criteria of overhead transmission lines |
| EN 50483-5:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 5: Electrical ageing test |
| IEC 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
| EN 50397-1:2006 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 1: Covered conductors |
| EN ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461:2009) |
| ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
| ISO 2859-2:1985 | Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection |
| EN 50483-6:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 6: Environmental testing |
| HD 474 : 200S1 | DIMENSIONS OF BALL AND SOCKET COUPLINGS OF STRING INSULATOR UNITS |
| IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
| ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
| IEC 60120:1984 | Dimensions of ball and socket couplings of string insulator units |
| EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
| EN 61284:1997 | Overhead lines - Requirements and tests for fittings |
| EN 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.