• Shopping Cart
    There are no items in your cart

EN 50397-2:2009

Current

Current

The latest, up-to-date edition.

Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteria

Published date

30-10-2009

Sorry this product is not available in your region.

Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Quality assurance
6 Classification of tests - Type tests, sample tests,
  routine tests
7 Tests
Annex A (normative) - Type tests, sample tests and routine
        tests
Annex B (informative) - Example of sampling with inspection
        by attributes
Annex C (informative) - Example of sampling with inspection
        by variable
Annex D (normative) - Special national conditions
Bibliography

Covered overhead line conductors are equipped with a plastic covering (XLPE-based) as protection against accidental contact with grounded parts respectively against accidental contact with other, at least covered live parts (e.g. other covered overhead line conductors) - This plastic cover is not a touch-proof, full protecting insulation - The covered overhead line conductors are designed for the use in high-voltage overhead lines with rated voltages up to 30 kV AC - The application of covered overhead line conductors is exclusively allowed on suitable insulators, which are designed for the rated voltage of the overhead line - As protection against negative influences by water penetration, the conductor may be equipped with measures to maintain longitudinal water tightness

Committee
CLC/TC 20
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

EN 50397-3:2010 Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 3: Guide to use
BS EN 50397-3:2010 Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. Guide to use
08/30182118 DC : DRAFT OCT 2008 BS EN 50397-3 - COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE
CEI EN 50397-3 : 2011 COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE
NF EN 50397-3 : 2010 COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE
I.S. EN 50397-3:2010 COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE

IEC 60826:2017 Design criteria of overhead transmission lines
EN 50483-5:2009 Test requirements for low voltage aerial bundled cable accessories - Part 5: Electrical ageing test
IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
EN 50397-1:2006 Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 1: Covered conductors
EN ISO 1461:2009 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461:2009)
ISO 1461:2009 Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods
ISO 2859-2:1985 Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection
EN 50483-6:2009 Test requirements for low voltage aerial bundled cable accessories - Part 6: Environmental testing
HD 474 : 200S1 DIMENSIONS OF BALL AND SOCKET COUPLINGS OF STRING INSULATOR UNITS
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
IEC 60120:1984 Dimensions of ball and socket couplings of string insulator units
EN ISO 9000:2015 Quality management systems - Fundamentals and vocabulary (ISO 9000:2015)
EN 61284:1997 Overhead lines - Requirements and tests for fittings
EN 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.