• EN 50397-2:2009

    Current The latest, up-to-date edition.

    Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteria

    Available format(s): 

    Language(s): 

    Published date:  29-10-2009

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements
    5 Quality assurance
    6 Classification of tests - Type tests, sample tests,
      routine tests
    7 Tests
    Annex A (normative) - Type tests, sample tests and routine
            tests
    Annex B (informative) - Example of sampling with inspection
            by attributes
    Annex C (informative) - Example of sampling with inspection
            by variable
    Annex D (normative) - Special national conditions
    Bibliography

    Abstract - (Show below) - (Hide below)

    Covered overhead line conductors are equipped with a plastic covering (XLPE-based) as protection against accidental contact with grounded parts respectively against accidental contact with other, at least covered live parts (e.g. other covered overhead line conductors) - This plastic cover is not a touch-proof, full protecting insulation - The covered overhead line conductors are designed for the use in high-voltage overhead lines with rated voltages up to 30 kV AC - The application of covered overhead line conductors is exclusively allowed on suitable insulators, which are designed for the rated voltage of the overhead line - As protection against negative influences by water penetration, the conductor may be equipped with measures to maintain longitudinal water tightness

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 20
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 50397-3:2010 Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 3: Guide to use
    BS EN 50397-3:2010 Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. Guide to use
    08/30182118 DC : DRAFT OCT 2008 BS EN 50397-3 - COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE
    CEI EN 50397-3 : 2011 COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE
    NF EN 50397-3 : 2010 COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE
    I.S. EN 50397-3:2010 COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60826:2017 Design criteria of overhead transmission lines
    EN 50483-5:2009 Test requirements for low voltage aerial bundled cable accessories - Part 5: Electrical ageing test
    IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
    EN 50397-1:2006 Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 1: Covered conductors
    EN ISO 1461:2009 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461:2009)
    ISO 1461:2009 Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods
    ISO 2859-2:1985 Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection
    EN 50483-6:2009 Test requirements for low voltage aerial bundled cable accessories - Part 6: Environmental testing
    HD 474 : 200S1 DIMENSIONS OF BALL AND SOCKET COUPLINGS OF STRING INSULATOR UNITS
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
    IEC 60120:1984 Dimensions of ball and socket couplings of string insulator units
    EN ISO 9000:2015 Quality management systems - Fundamentals and vocabulary (ISO 9000:2015)
    EN 61284:1997 Overhead lines - Requirements and tests for fittings
    EN 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective