1 Scope
2 Normative references
3 Terms and definitions
4 Physical quantities, units and constants
5 General process
6 Site analysis and case determination
7 Determination of field quantity to measure in relation to
the distance to source antennas
8 Requirements of measurement systems
9 Measurement procedures
10 Assessment of the field strength at maximum traffic of a
cellular network
11 Uncertainty
12 Presentation of results
Annex A (informative) - Main services operating RF
Annex B (informative) - Sweeping method
Annex C (informative) - Example of broadband equipment use
Annex D (informative) - Spectrum analyser settings
Annex E (informative) - Measuring and evaluating different
broadcast signals in respect to EMF
Annex F (informative) - WCDMA measurement and calibration using
a code domain analyser
Annex G (informative) - Influence of human body on probe
measurements of the electrical field strength
Annex H (informative) - Spatial averaging
Annex I (informative) - Maximum traffic estimation of cellular
network contribution
Annex J (informative) - WiFi measurements
Annex K (informative) - Examples of implementation of this
standard in the context of Council Recommendation
1999/519/EC
Annex L (informative) - FDD LTE measurements
Bibliography
Defines the vicinity of base station and the measurement methods, the measurement systems and the post processing that shall be used to determine in-situ the electromagnetic field for human exposure assessment in the frequency range 100 kHz to 300 GHz.
Committee |
TC 106X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
VDE 0848-492 : 2014 | Identical |
NF EN 50492 : 2009 AMD 1 2014 | Identical |
I.S. EN 50492:2008 | Identical |
BS EN 50492 : 2008 | Identical |
SN EN 50492:2008+A1:2014 | Identical |
NEN EN 50492 : 2009 AMD 1 2014 | Identical |
PN EN 50492 : 2009 AMD 1 2014 | Identical |
UNE-EN 50492:2008/A1:2014 | Identical |
NBN EN 50492 : 2009 AMD 1 2014 | Identical |
DIN EN 50492 : 2014 | Identical |
CEI EN 50492/A1:2014 | Identical |
NF EN 50554 : 2011 | BASIC STANDARD FOR THE IN-SITU ASSESSMENT OF A BROADCAST SITE RELATED TO GENERAL PUBLIC EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS |
BS IEC 62232:2011 | Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure |
CEI EN 50554 : 2013 | BASIC STANDARD FOR THE IN-SITU ASSESSMENT OF A BROADCAST SITE RELATED TO GENERAL PUBLIC EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS |
EN 50554:2010 | Basic standard for the in-situ assessment of a broadcast site related to general public exposure to radio frequency electromagnetic fields |
UNE-EN 50554:2011 | Basic standard for the in-situ assessment of a broadcast site related to general public exposure to radio frequency electromagnetic fields |
PREN 50554 : DRAFT 2010 | BASIC STANDARD FOR THE IN-SITU ASSESSMENT OF A BROADCAST SITE RELATED TO GENERAL PUBLIC EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS |
BS EN 50554:2010 | Basic standard for the in-situ assessment of a broadcast site related to general public exposure to radio frequency electromagnetic fields |
10/30216754 DC : 0 | BS EN 50554 - BASIC STANDARD FOR THE IN-SITU ASSESSMENT OF A BROADCAST SITE RELATED TO GENERAL PUBLIC EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS |
CEI 211-7/E : 2013 | GUIDE FOR THE MEASUREMENT AND THE EVALUATION OF ELECTROMAGNETIC FIELDS IN THE FREQUENCY RANGE 10 KHZ - 300 GHZ, WITH REFERENCE TO THE HUMAN EXPOSURE ANNEX E: MEASUREMENT OF THE ELECTROMAGNETIC FIELDS FROM BASE RADIO STATION FOR MOBILE TELECOMMUNICATION SYSTEMS (2G, 3G, 4G) |
I.S. EN 50554:2010 | BASIC STANDARD FOR THE IN-SITU ASSESSMENT OF A BROADCAST SITE RELATED TO GENERAL PUBLIC EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 50400 : 2006 AMD 1 2012 | BASIC STANDARD TO DEMONSTRATE THE COMPLIANCE OF FIXED EQUIPMENT FOR RADIO TRANSMISSION (110 MHZ - 40 GHZ) INTENDED FOR USE IN WIRELESS TELECOMMUNICATION NETWORKS WITH THE BASIC RESTRICTIONS OR THE REFERENCE LEVELS RELATED TO GENERAL PUBLIC EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS, WHEN PUT INTO SERVICE |
EN 50383 : 2010 COR 2013 | BASIC STANDARD FOR THE CALCULATION AND MEASUREMENT OF ELECTROMAGNETIC FIELD STRENGTH AND SAR RELATED TO HUMAN EXPOSURE FROM RADIO BASE STATIONS AND FIXED TERMINAL STATIONS FOR WIRELESS TELECOMMUNICATION SYSTEMS (110 MHZ - 40 GHZ) |
119999/5/EC : 1999 | DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 1999 ON RADIO EQUIPMENT AND TELECOMMUNICATIONS TERMINAL EQUIPMENT AND THE MUTUAL RECOGNITION OF THEIR CONFORMITY |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.