    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviated terms
    5 Quick start guide and how to use this document
    6 Evaluation processes for product compliance,
       product installation compliance and in-situ RF
       exposure assessments
    7 Determining the evaluation method
    8 Evaluation methods
    9 Uncertainty
    10 Reporting
    Annex A (informative) - Source environment plane and
            guidance on the evaluation method selection
    Annex B (normative) - Evaluation methods
    Annex C (informative) - Rationale supporting simplified
            product installation criteria
    Annex D (informative) - Guidance on comparing evaluated
            parameters with a limit value
    Annex E (informative) - Uncertainty
    Annex F (informative) - Technology-specific guidance
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    IEC 62232:2017(E) provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure. This document:- considers intentionally radiating RBS which transmit on one or more antennas using one or more frequencies in the range 110 MHz to 100 GHz;- considers the impact of ambient sources on RF exposure at least in the 100 kHz to 300 GHz frequency range;- specifies the methods to be used for RF exposure evaluation for compliance assessment applications, namely: - product compliance - determination of compliance boundary information for an RBS product before it is placed on the market; - product installation compliance - determination of the total RF exposure levels in accessible areas from an RBS product and other relevant sources before the product is put into service; - in-situ RF exposure assessment – measurement of in-situ RF exposure levels in the vicinity of an RBS installation after the product has been taken into operation;- describes several RF field strength and SAR measurement and computation methodologies with guidance on their applicability to address both the in-situ evaluation of installed RBS and laboratory-based evaluations;- describes how surveyors, with a sufficient level of expertise, establish their specific evaluation procedures appropriate for their evaluation purpose;- provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value and- provides short descriptions of the informative example case studies given in the companion Technical Report IEC TR 62669 [1]This second edition cancels and replaces the first edition published in 2011 and constitutes a technical revision.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 106X
    Development Note Supersedes EN 50383, EN 50400 and EN 50492. (12/2017)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    IEC 60050-394:2007 International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors
    IEC 62209-2:2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
    EN 62311:2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)
    CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
    IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
    IEC 62479:2010 Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
    IEEE C95.3-2002 IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz
    IEC TR 62630:2010 Guidance for evaluating exposure from multiple electromagnetic sources
    IEEE C95.1-2005 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz
    IEC 62311:2007 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)
    EN 62479:2010 Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
    EN 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
    IEEE 145-2013 REDLINE IEEE Standard for Definitions of Terms for Antennas
    IEC 60050-121:1998 International Electrotechnical Vocabulary (IEV) - Part 121: Electromagnetism
    EN 62209-2:2010 HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODYMOUNTED WIRELESS COMMUNICATION DEVICES - HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES - PART 2: PROCEDURE TO DETERMINE THE SPECIFIC ABSORPTION RATE (SAR) FOR WIRELESS COMMUNICATION DEVICES USED IN CLOSE PROXIMITY TO THE HUMAN BODY (FREQUENCY RANGE OF 30 MHZ TO 6 GHZ)
    TR 102 457 : 1.1.1 TRANSMISSION AND MULTIPLEXING (TM); STUDY ON THE ELECTROMAGNETIC RADIATED FIELD IN FIXED RADIO SYSTEMS FOR ENVIRONMENTAL ISSUES
    IEC 60050-705:1995 International Electrotechnical Vocabulary (IEV) - Part 705: Radio wave propagation
    IEC 60050-712:1992 International Electrotechnical Vocabulary (IEV) - Part 712: Antennas
    IEC TR 62669:2011 Case studies supporting IEC 62232 - Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective