EN 50600-4-1:2016
Current
The latest, up-to-date edition.
Information technology - Data centre facilities and infrastructures - Part 4-1: Overview of and general requirements for key performance indicators
23-12-2016
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Conformance
5 Key Performance Indicators (KPIs)
6 Data Centre Boundaries
7 Data Centre spaces and equipment
Annex A (informative) - KPI constraints and data centre criticality
Bibliography
This European Standard specifies the following for the other standards in the EN 50600 4-X series:a)a common structure,b)definitions, terminology and boundary conditions for KPIs of data centre resource usage effectiveness and efficiency,c)common requirements for KPIs of data centre resource usage effectiveness and efficiency,d)common objectives for KPIs of the data centre resource effectiveness and efficiency,e)general information regarding the use of KPIs of data centre resource usage effectiveness and efficiency.
Committee |
CLC/TC 215
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
VDE 0801-600-4-1 : 2017 | Identical |
BS EN 50600-4-1:2016 | Identical |
PN EN 50600-4-1 : 2017 | Identical |
UNE-EN 50600-4-1:2016 | Identical |
NF EN 50600-4-1 : 2017 | Identical |
NEN EN 50600-4-1 : 2017 | Identical |
CEI EN 50600-4-1 : 1ED 2017 | Identical |
DIN EN 50600-4-1 : 2017 | Identical |
I.S. EN 50600-4-1:2016 | Identical |
SN EN 50600-4-1 : 2016 | Identical |
PNE-FprEN 50600-4-1:2016 | Identical |
PD CLC/TR 50600-99-1:2017 | Information technology. Data centre facilities and infrastructures Recommended practices for energy management |
CLC/TR 50600-99-1:2017 | Information technology - Data centre facilities and infrastructures - Part 99-1: Recommended practices for energy management |
I.S. EN 50600-4-3:2016 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 4-3: RENEWABLE ENERGY FACTOR |
EN 50600-4-2:2016/AC:2017-02 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 4-2: POWER USAGE EFFECTIVENESS |
I.S. EN 50600-4-2:2016&AC:2017-02&A1:2019 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 4-2: POWER USAGE EFFECTIVENESS |
EN 50600-4-3:2016 | Information technology - Data centre facilities and infrastructures - Part 4-3: Renewable Energy Factor |
CEI EN 50600-4-2 : 1ED 2017 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 4-2: POWER USAGE EFFECTIVENESS |
BS EN 50600-4-2:2016 | Information technology. Data centre facilities and infrastructures Power Usage Effectiveness |
S.R. CLC/TR 50600-99-1:2017 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 99-1: RECOMMENDED PRACTICES FOR ENERGY MANAGEMENT |
EN 50600-3-1:2016 | Information technology - Data centre facilities and infrastructures - Part 3-1: Management and operational information |
CLC/TR 50600-99-1:2017 | Information technology - Data centre facilities and infrastructures - Part 99-1: Recommended practices for energy management |
EN 50600-2-1:2014 | Information technology - Data centre facilities and infrastructures - Part 2-1: Building construction |
EN 50600-2-3:2014 | Information technology - Data centre facilities and infrastructures - Part 2-3: Environmental control |
EN 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
EN 50600-1:2012 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 1: GENERAL CONCEPTS |
IEC 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
EN 50600-2-5:2016 | Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems |
EN 50600-2-4:2015 | Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure |
EN 50600-4-2:2016/AC:2017-02 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 4-2: POWER USAGE EFFECTIVENESS |
EN 50600-4-3:2016 | Information technology - Data centre facilities and infrastructures - Part 4-3: Renewable Energy Factor |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.