• There are no items in your cart

EN 54-22:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire detection and fire alarm systems - Part 22: Resettable line-type heat detectors

Superseded date

12-03-2020

Superseded by

EN 54-22:2015+A1:2020

Published date

20-05-2015

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Product characteristics
5 Testing, assessments and sampling methods
6 Assessment and verification of constancy of
  performance (AVCP)
7 Classification
8 Marking, labelling and packaging
Annex A (normative) - Arrangement of the sensing
        element in the fire test room
Annex B (normative) - Flaming liquid test fires
        (TF6F, TF6 and TF6S)
Annex C (normative) - Test arrangement for the
        sensing element of linear heat detector in
        the heat tunnel
Annex D (informative) - Apparatus for mounting of the
        sensing element of linear heat detector in the
        heat tunnel
Annex E (normative) - Mounting of the sensing element
        of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time and
        of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time and
        response temperature measurements
Annex G (informative) - Construction of the heat
        tunnel
Annex H (normative) - Test arrangement for vibration tests
        for sensing element
Annex I (normative) - Test apparatus for impact test on the
        sensing element
Annex J (informative) - Data supplied with resettable
        line-type heat detectors
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Regulation
Bibliography

This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of resettable line-type heat detectors to this EN.This European Standard also covers resettable line-type heat detectors intended for use in the local protection of plant and equipment.Resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this EN.This European Standard does not cover line-type heat detectors that are based on non-resettable, fixed temperature electrical cables (so called digital systems).

Committee
CEN/TC 72
DevelopmentNote
Supersedes PREN 54-22. (05/2015)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
DIN EN 54-22:2015-07 Identical
NF EN 54-22 : 2015 Identical
NBN EN 54-22 : 2015 Identical
NEN EN 54-22 : 2015 Identical
NS EN 54-22 : 2015 Identical
I.S. EN 54-22:2015 Identical
PN EN 54-22 : 2015 Identical
SN EN 54-22 : 2015 Identical
UNI EN 54-22 : 2015 Identical
UNE-EN 54-22:2016 Identical
BS EN 54-22:2015 Identical
ONORM EN 54-22 : 2015 Identical

11/30249544 DC : 0 BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.