• Shopping Cart
    There are no items in your cart

EN 54-28:2016

Current

Current

The latest, up-to-date edition.

Fire detection and fire alarm system - Part 28: Non-resettable line-type heat detectors

Published date

17-02-2016

Sorry this product is not available in your region.

European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Product characteristics
5 Testing, assessment and sampling methods
6 Assessment and Verification of Constancy of Performance (AVCP)
7 Classification and designation
8 Marking, labelling and packaging
Annex A (normative) - Mounting of the sensing element
         of NLTHD in the heat tunnel
Annex B (normative) - Heat tunnel for response temperature
         measurements
Annex C (informative) - Construction of the heat tunnel
Annex D (normative) - Test arrangement for vibration tests
        for sensing element
Annex E (normative) - Test apparatus for impact test
        on the sensing element
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Regulation
Bibliography

This European Standard applies to non-resettable line-type heat detectors consisting of a sensing element using an electrical sensor cable which can be connected to a sensor control unit or either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in and around buildings and civil engineering works (see EN 54 1:2011).The non-resettable sensing element has a fixed temperature alarm threshold and does not distinguish between short circuit and alarm condition.This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of non-resettable line-type heat detectors to this European Standard.This European Standard also covers non-resettable line-type heat detectors intended for use in the local protection of plant and equipment.Non-resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this standard.

Committee
CEN/TC 72
DevelopmentNote
Supersedes PREN 54-28. (03/2016)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

Standards Relationship
DIN EN 54-28:2016-07 Identical
NF EN 54-28 : 2016 Identical
NBN EN 54-28 : 2016 Identical
NEN EN 54-28 : 2016 Identical
NS EN 54-28 : 2016 Identical
I.S. EN 54-28:2016 Identical
PN EN 54-28 : 2016 Identical
SN EN 54-28:2016 Identical
UNI EN 54-28 : 2016 Identical
UNE-EN 54-28:2019 Identical
BS EN 54-28:2016 Identical

11/30249544 DC : 0 BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.