• Shopping Cart
    There are no items in your cart

EN 54-29:2015

Current

Current

The latest, up-to-date edition.

Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors

Published date

08-04-2015

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test and assessment and sampling methods
6 Assessment and verification of constancy of performance (AVCP)
7 Classification and designation
8 Marking, Labelling and Packaging
Annex A (normative) - Smoke tunnel for smoke response values
Annex B (normative) - Test aerosol for smoke response value
        measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Heat tunnel for heat response value
Annex E (normative) - Apparatus for dazzling test
Annex F (informative) - Apparatus for impact test
Annex G (normative) - Fire test room
Annex H (normative) - Open wood fire (TF1)
Annex I (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex J (normative) - Glowing smouldering cotton fire (TF3)
Annex K (normative) - Open plastics (polyurethane) fire (TF4)
Annex L (normative) - Liquid (heptane) fire (TF5)
Annex M (normative) - Low temperature black smoke (decalene)
        liquid fire (TF8)
Annex N (informative) - Information concerning the construction of
        the smoke tunnel
Annex O (informative) - Construction of the heat tunnel
Annex P (informative) - Information concerning test procedures and
        requirements for the response to slowly developing fires
Annex Q (informative) - Information concerning the construction of the
        measuring ionization chamber
Annex ZA (informative) - Clauses of this European Standard addressing
         the provisions of the EU Construction Products Regulation
Bibliography

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena.This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke and heat sensors to this EN.Point detectors using a combination of smoke and heat sensors having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this European Standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method).NOTECertain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this European Standard.

Committee
CEN/TC 72
DevelopmentNote
Supersedes PREN 54-29. (04/2015)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

Standards Relationship
BS EN 54-29:2015 Identical
UNI EN 54-29 : 2015 Identical
DIN EN 54-29:2015-06 Identical
PN EN 54-29 : 2015 Identical
SN EN 54-29:2015 Identical
UNE-EN 54-29:2019 Identical
NF EN 54-29 : 2015 Identical
NS EN 54-29 : 2015 Identical
I.S. EN 54-29:2015 Identical
NBN EN 54-29 : 2015 Identical
NEN EN 54-29 : 2015 Identical

11/30249544 DC : 0 BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.