• Shopping Cart
    There are no items in your cart

EN 54-31:2014+A1:2016

Current

Current

The latest, up-to-date edition.

Fire detection and fire alarm systems - Part 31: Multi-sensor fire detectors - Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors

Published date

27-04-2016

Sorry this product is not available in your region.

European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Classification and designation
7 Marking, Labelling and Packaging
Annex A (normative) - Smoke tunnel for smoke response
         values
Annex B (normative) - Test aerosol for smoke response
        value measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Gas test chamber for CO response
         threshold value and crosssensitivity to chemical agents
Annex E (normative) - Heat tunnel for heat response value
Annex F (normative) - Measuring instruments for CO
Annex G (informative) - Establishing exposure levels of
        chemical agents
Annex H (normative) - Apparatus for dazzling test
Annex I (informative) - Apparatus for impact test
Annex J (normative) - Fire test room
Annex K (normative) - Open wood fire (TF1)
Annex L (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex M (normative) - Glowing smouldering cotton fire (TF3)
Annex N (normative) - Open plastics (polyurethane) fire (TF4)
Annex O (normative) - Liquid (heptane) fire (TF5)
Annex P (normative) - Low temperature black smoke
        (decalene) liquid fire (TF8)
Annex Q (informative) - Information concerning the
        construction of the smoke tunnel
Annex R (informative) - Information concerning the
        construction of the gas test chamber
Annex S (informative) - Construction of the heat tunnel
Annex T (informative) - Information concerning test
        procedures and requirements for response to slowly
        developing fires, aging and contamination
Annex U (informative) - Information concerning the
        construction of the measuring ionization chamber
Bibliography

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one carbon monoxide (CO) sensor and optionally one or more heat sensors, utilizing the combination of the detected phenomena. This European Standard covers only modes of operation, where at least the signals of both smoke and carbon monoxide sensors are continuously evaluated.This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke, carbon monoxide and optionally heat sensors to this EN.Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors, which are having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method).

Committee
CEN/TC 72
DevelopmentNote
Supersedes PREN 54-31. (12/2014) 2014 Edition Re-Issued in April 2016 & incorporates AMD 1 2016. (05/2016)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

11/30249544 DC : 0 BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 54-26:2015 Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.