• EN 60076-5:2006

    Current The latest, up-to-date edition.

    Power transformers - Part 5: Ability to withstand short-circuit

    Available format(s): 

    Language(s): 

    Published date:  09-06-2006

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Requirements with regard to ability to withstand short circuit
      3.1 General
      3.2 Overcurrent conditions
    4 Demonstration of ability to withstand short circuit
      4.1 Thermal ability to withstand short circuit
      4.2 Ability to withstand the dynamic effects of short circuit
    Annex A (informative) Theoretical evaluation of the ability to
            withstand the dynamic effects of short circuit
    Annex B (informative) Definition of similar transformer
    Annex ZA (normative) Normative references to international
             publications with their corresponding European publications

    Abstract - (Show below) - (Hide below)

    Identifies the requirements for power transformers to sustain without damage the effects of overcurrents originated by external short circuits. Describes the calculation procedures used to demonstrate the thermal ability of a power transformer to withstand such overcurrents and both the special test and the theoretical evaluation method used to demonstrate the ability to withstand the relevant dynamic effects.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 14
    Development Note Supersedes HD 398.5 (03/2001)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 60076-11:2004 Power transformers Dry-type transformers
    BS EN 50329 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    CEI EN 60076-14 : 2014 POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    BS EN 60076-13:2006 Power transformers Self-protected liquid-filled transformers
    UNE-EN 50541-1:2012 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
    KTA 3705 : 2013(R2017) SWITCHGEAR FACILITIES, TRANSFORMERS AND DISTRIBUTION NETWORKS FOR THE ELECTRICAL POWER SUPPLY OF THE SAFETY SYSTEM IN NUCLEAR POWER PLANTS
    I.S. EN 60076-11:2004 POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
    I.S. EN 60076-16:2011 POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011)
    I.S. EN 60137:2017 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
    I.S. EN 62271-212:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS)
    I.S. EN 60076-14:2013 POWER TRANSFORMERS - PART 14: LIQUIDIMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS (IEC 60076-14:2013 (EQV))
    EN 60137:2017 Insulated bushings for alternating voltages above 1 000 V
    UNE-EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
    EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
    EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
    EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
    EN 62271-202:2014/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014)
    EN 60726:2003 Dry-type power transformers
    I.S. EN 50327:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
    BS EN 60076-14:2013 Power transformers Liquid-immersed power transformers using high-temperature insulation materials
    I.S. EN 60076-13:2006 POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS
    BS EN 60076-6:2008 Power transformers Reactors
    BS EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV General requirements
    UNE-EN 60076-14:2014 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
    CEI EN 60076-16 : 2012 POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS
    BS EN 60137:2017 Insulated bushings for alternating voltages above 1000 V
    I.S. EN 50299:2004 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72.5 KV TO 550 KV
    I.S. EN 60310:2016 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK
    I.S. EN 62271-202:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION
    UNE-EN 60137:2011 Insulated bushings for alternating voltages above 1 000 V
    BS EN 60076-1:2011 Power transformers General
    CEI EN 50541-1 : 2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
    BS EN 50327:2003 Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups
    I.S. EN 50541-1:2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
    PREN 50541-1 : DRAFT 2009 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
    I.S. EN 60076-6:2008 POWER TRANSFORMERS - PART 6: REACTORS
    UNE-EN 62271-202:2015 High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation
    EN 50532:2010 Compact Equipment Assembly for Distribution Substations (CEADS)
    I.S. EN 60726:2003 DRY-TYPE POWER TRANSFORMERS
    I.S. EN 50532:2010 COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
    BS EN 60076-16:2011 Power transformers Transformers for wind turbines applications
    UNE-EN 60076-16:2012 Power transformers - Part 16: Transformers for wind turbines applications
    BS EN 60726:2003 Dry-type power transformers
    BS EN 60310:2016 Railway applications. Traction transformers and inductors on board rolling stock
    CEI EN 60076-1 : 2015 POWER TRANSFORMERS - PART 1: GENERAL
    CEI EN 60076-6 : 2015 POWER TRANSFORMERS - PART 6: REACTORS
    BS EN 62271-212:2017 High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS)
    BS EN 50532:2010 Compact equipment assembly for distribution substations (CEADS)
    UNE-EN 60076-1:2013 Power transformers - Part 1: General
    09/30202403 DC : 0 BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
    UNE-EN 50532:2011 Compact Equipment Assembly for Distribution Substations (CEADS)
    EN 60076-16:2011 Power transformers - Part 16: Transformers for wind turbines applications
    09/30211604 DC : 0 BS EN 50541-1 - THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
    CEI EN 60076-13 : 2007 POWER TRANSFORMERS - PART 13: SELF PROTECTED LIQUID FILLED TRANSFORMERS
    CEI EN 60076-11 : 2006 POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
    BS EN 61800-4:2003 Adjustable speed electrical power drive systems General requirements. Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV
    CEI EN 60310 : 2016 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK
    I.S. EN 50329:2007 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    I.S. EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    CEI EN 60137 : 2009 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
    CEI EN 61800-4 : 2003 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A/C/ POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV
    I.S. EN 61800-4:2003 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV
    BS EN 62271-202:2014 High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation
    EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
    EN 50329:2003/A1:2010 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    EN 60076-6:2008 Power transformers - Part 6: Reactors
    EN 60076-13 : 2006 POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS
    EN 61800-4:2003 Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV
    EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    EN 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
    EN 60310:2016/AC:2018-03 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018)

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
    IEC 60076-8:1997 Power transformers - Part 8: Application guide
    IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
    IEC 60076-1:2011 Power transformers - Part 1: General
    EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective