Section 1. General
1.1 Scope and object
1.2 Normative references
1.3 Definitions
Section 2. Insulators
2.1 Insulator designs and insulating materials
2.2 Values which characterize a post insulator
2.3 Identification of insulators
Section 3. Classification of the tests, sampling
rules and procedures
3.1 Classification of the tests
3.2 Quality assurance
3.3 General requirements for type tests
3.4 General requirements for sample tests
Section 4. Test procedures for electrical tests
4.1 General requirements for high-voltage tests
4.2 Standard atmospheric conditions and correction
factors for electrical tests
4.3 Artificial rain parameters for wet tests
4.4 Mounting arrangements for electrical tests
4.5 Dry lightning-impulse withstand voltage test-Type test
4.6 Dry or wet switching-impulse withstand voltage tests
- Type test
4.7 Dry power-frequency withstand voltage test - Type test
(applicable only to post insulators for indoor use)
4.8 Wet power-frequency withstand voltage test - Type test
(applicable only to post insulators for outdoor use)
4.9 Puncture test - Sample test
4.10 Routine electrical test
Section 5. Test procedures for mechanical and other tests
5.1 Verification of the dimensions - Type and sample test
5.2 Mechanical failing load test - Type and sample test
5.3 Test for deflection under load - Special type test
5.4 Temperature cycle test - Sample test
5.5 Routine thermal shock test (applicable only to
toughened glass insulating parts)
5.6 Porosity test - Sample test (applicable only to
ceramic post insulators)
5.7 Galvanizing test - Sample test
5.8 Routine visual inspection
5.9 Routine mechanical test
Section 6. Tests applicable to post insulators
6.1 Type tests
6.2 Sample tests
6.3 Routine tests
6.4 Summary of tests on post insulators
Annex A (informative) Methods of testing for tolerances
of parallelism, eccentricity, angular deviation,
camber and shed angle of post insulators
Annex B (informative) Methods of routine testing of
unassembled insulator units
Annex C (informative) Bibliography
Annex ZA (normative) Other international publications
quoted in this standard with the references of
the relevant European publications
Applies to post insulators and post insulator units of ceramic material or glass, for indoor and outdoor use in electrical installations or equipment, operating on alternating current with a nominal voltage greater than 1000 V and a frequency not more than 100 Hz.
Committee |
SR 36
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
BS EN 60168:1995 | Identical |
NEN EN IEC 60168 : 1995 AMD 2 2001 | Identical |
UNE-EN 60168:1997 | Identical |
I.S. EN 60168:1996 | Identical |
NF EN 60168 : 95 AMD 2 2001 | Similar to |
NBN EN 60168 : 1995 AMD 2 2001 | Identical |
PN EN 60168 : 1999 AMD 2 2002 | Identical |
SN EN 60168 : 1994 AMD 2 2000 | Identical |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Identical |
VDE 0674-1 : 2001-12 | Identical |
DIN EN 60168 : 2001-12 | Identical |
NEN 10168 : 1995 | Similar to |
CEI EN 60168/A2:2001 | Identical |
UNE-EN 60168/A2:2001 | Identical |
UNE-EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
CEI EN 61462 : 2008 | COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS |
CEI EN 60437 : 1998 | RADIO INTERFERENCE TEST ON HIGH-VOLTAGE INSULATORS |
CEI EN 62231 : 2007 | COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
I.S. EN 60437:1999 | RADIO INTERFERENCE TEST ON HIGH-VOLTAGE INSULATORS |
15/30298489 DC : 0 | BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
PREN 50119 : DRAFT 2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
I.S. EN 61462:2007 | COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS |
I.S. EN 50124-1:2017 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
EN 62231:2006 | Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria |
EN 60437:1997 | Radio interference test on high-voltage insulators |
BS EN 61462:2007 | Composite hollow insulators. Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V. Definitions, test methods, acceptance criteria and design recommendations |
PREN 50124-1 : DRAFT 2015 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
17/30341013 DC : DRAFT AUG 2017 | BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
I.S. EN 62231:2007 | COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1 000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
I.S. EN 50119:2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 60437:1998 | Radio interference test on high-voltage insulators |
NF EN 50119 : 2010 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 50119 : 2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 62231:2007 | Composite station post insulators for substations with a.c. voltages greater than 1000 V up to 245 kV. Definitions, test methods and acceptance criteria |
BS EN 61264:1999 | Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
I.S. EN 50119:2020 | Railway applications - Fixed installations - Electric traction overhead contact lines |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
EN 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
BS EN 50124-1:2017 | Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
ISO 1463:2003 | Metallic and oxide coatings Measurement of coating thickness Microscopical method |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
HD 540.2 : 200S1 | INSULATION COORDINATION - APPLICATION GUIDE |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
HD 578 : 200S1 | CHARACTERISTICS OF INDOOR AND OUTDOOR POST INSULATORS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1000 V |
ISO 1459:1973 | Metallic coatings — Protection against corrosion by hot dip galvanizing — Guiding principles |
IEC 60273:1990 | Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
IEC 60071-3:1982 | Insulation co-ordination - Part 3: Phase-to-phase insulation co-ordination - Principles, rules and application guide |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
ISO 1460:1992 | Metallic coatings Hot dip galvanized coatings on ferrous materials Gravimetric determination of the mass per unit area |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
ISO 2064:1996 | Metallic and other inorganic coatings — Definitions and conventions concerning the measurement of thickness |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.