• Shopping Cart
    There are no items in your cart

EN 60297-3-105:2009

Current

Current

The latest, up-to-date edition.

Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-105: Dimensions and design aspects for 1U high chassis

Published date

08-01-2009

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Arrangement overview
5 Dimensions of the 1U chassis
  5.1 Chassis type A
  5.2 Chassis type B
  5.3 Chassis type C
6 Climatic, mechanical tests (safety aspects, EMC, seismic)
Annex A (informative) - Chassis and rack/cabinet relationship
Annex B (informative) - Cooling air flow
Annex C (informative) - Chassis depth relationship to the
                        rack/cabinet
Annex ZA (normative) - Normative references to
                       international publications with
                       their corresponding European
                       publications

IEC 60297-3-105:2008 specifies the dimensions for 1U chassis mounted into IEC 60297-3-100 compliant racks/cabinets where dimensions, loaded weight and accessibility require differing assembly methods. Guidance for cooling and reference for EMC, seismic and for the climatic and mechanical requirements and tests are provided, as defined in the IEC 61587 series.

Committee
CLC/SR 48D
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

I.S. EN 60297-3-108:2015 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - DIMENSIONS OF MECHANICAL STRUCTURES OF THE 482,6 MM (19 IN) SERIES - PART 3-108: DIMENSIONS OF R-TYPE SUBRACKS AND PLUG-IN UNITS (IEC 60297-3-108:2014)
EN 50310:2016 Telecommunications bonding networks for buildings and other structures
UNE-HD 60364-4-444:2013 Low-voltage electrical installations -- Part 4-444: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
UNE-EN 50310:2016 Telecommunications bonding networks for buildings and other structures
I.S. EN 50310:2016 TELECOMMUNICATIONS BONDING NETWORKS FOR BUILDINGS AND OTHER STRUCTURES
BS EN 60297-3-108:2015 Mechanical structures for electronic equipment. Dimensions of mechanical structures of the 482,6 mm (19 in) series Dimensions of R-type subracks and plug-in units
I.S. HD 60364-4-444:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES
BS EN 50310:2016 Telecommunications bonding networks for buildings and other structures
EN 60297-3-108:2015 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-108: Dimensions of R-type subracks and plug-in units
HD 60364-4-444:2010/AC:2012 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES

EN 60297-3-100:2009 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-100: Basic dimensions of front panels, subracks, chassis, racks and cabinets
EN 61587-2:2011 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 2: SEISMIC TESTS FOR CABINETS AND RACKS (IEC 61587-2:2011)
IEC 61587-2:2011 Mechanical structures for electronic equipment - Tests for IEC 60917 and 60297 - Part 2: Seismic tests for cabinets and racks
IEC 61587-3:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks
IEC 61587-1:2016 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
EN 61587-1:2017 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
EN 61587-3:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks
IEC 60050-581:2008 International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment
IEC 60297-3-100:2008 Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-100: Basic dimensions of front panels, subracks, chassis, racks and cabinets
IEC 60917-1:1998+AMD1:2000 CSV Modular order for the development of mechanical structures for electronic equipment practices - Part 1: Generic standard

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.