EN 60512-27-100:2012
Current
The latest, up-to-date edition.
Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on IEC 60603-7 series connectors - Tests 27a to 27g
17-02-2012
FOREWORD
1 Scope and object
2 Normative references
3 Terms, definitions, acronyms and symbols
4 Overall test arrangement
5 Connector measurement up to 500 MHz
6 Construction and qualification of TFCs for NEXT, FEXT
and return loss measurements
Annex A (informative) - Impedance controlled measurement
fixture
Annex B (normative) - Termination of balun
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
IEC 60512-27-100:2011 specifies the test methods for transmission performance for IEC 60603-7 series connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements of the detail specifications and of this standard. The test methods provided are: - insertion loss, - return loss, - near-end crosstalk (NEXT), - far-end crosstalk (FEXT), - transverse conversion loss (TCL) and - transverse conversion transfer loss (TCTL). For the transfer impedance (Zt) test, see IEC 60512-26-100 and for the coupling attenuation, see IEC 62153-4-12.
Committee |
CLC/SR 48B
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
PN EN 60512-27-100 : 2012 | Identical |
CEI EN 60512-27-100 : 2012 | Identical |
VDE 0687-512-27-100 : 2012 | Identical |
IEC 60512-27-100:2011 | Identical |
UNE-EN 60512-27-100:2012 | Identical |
NEN EN IEC 60512-27-100 : 2012 | Identical |
I.S. EN 60512-27-100:2012 | Identical |
DIN EN 60512-27-100 : 2012 | Identical |
BS EN 60512-27-100:2012 | Identical |
NBN EN 60512-27-100 : 2012 | Identical |
NF EN 60512-27-100 : 2012 | Identical |
PNE-FprEN 60512-27-100 | Identical |
BS EN 60512-29-100:2015 | Connectors for electronic equipment. Tests and measurements Signal integrity tests up to 500 MHz on M12 style connectors. Tests 29a to 29g |
I.S. EN 60603-7-5:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-5: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
CEI EN 60603-7-2 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-2: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 100 MHZ |
I.S. EN 50289-1-1:2017 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-1: ELECTRICAL TEST METHODS - GENERAL REQUIREMENTS |
EN 60603-7-5:2010 | Connectors for electronic equipment - Part 7-5: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
EN 60603-7-2:2010 | Connectors for electronic equipment - Part 7-2: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
EN 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
EN 60603-7-71 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-71: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 1000 MHZ |
EN 60603-7-7:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-7: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 600 MHZ |
EN 60512-29-100:2015 | Connectors for electronic equipment - Tests and measurements - Part 29-100: Signal integrity tests up to 500 MHz on M12 style connectors - Tests 29a to 29g |
BS EN 60603-7-71:2010 | Connectors for electronic equipment Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 1000 MHz |
CEI EN 60603-7-82 : 1ED 2017 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ |
CEI EN 60603-7-4 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-4: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
CEI EN 60603-7-71 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-71: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 1000 MHZ |
BS EN 50289-1-1:2017 | Communication cables. Specifications for test methods Electrical test methods. General requirements |
I.S. EN 60603-7-71:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-71: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 1000 MHZ |
PREN 50289-1-1 : DRAFT 2016 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-1: ELECTRICAL TEST METHODS - GENERAL REQUIREMENTS |
EN 60603-7-82:2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ (IEC 60603-7-82:2016) |
BS EN 60603-7-2:2010 | Connectors for electronic equipment Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
CEI EN 60603-7-5 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-5: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
BS EN 60603-7-7:2010 | Connectors for electronic equipment Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz |
BS EN 60603-7-5:2010 | Connectors for electronic equipment Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
I.S. EN 60603-7-82:2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ |
CEI EN 60603-7-7 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-7: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 600 MHZ |
16/30342119 DC : 0 | BS EN 50289-1-1 - COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-1: ELECTRICAL TEST METHODS - GENERAL REQUIREMENTS |
UNE-EN 50289-1-1:2017 | Communication cables - Specifications for test methods - Part 1-1: Electrical test methods - General requirements |
I.S. EN 60603-7-4:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-4: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
BS EN 60603-7-4:2010 | Connectors for electronic equipment Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
I.S. EN 60603-7-2:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-2: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 100 MHZ |
BS EN 60603-7-82:2016 | Connectors for electronic equipment Detail specification for 8-way, 12 contacts, shielded, free and fixed connectors, for data transmission with frequencies up to 2 000 MHz |
I.S. EN 60603-7-7:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-7: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 600 MHZ |
EN 50289-1-1:2017 | Communication cables - Specifications for test methods - Part 1-1: Electrical test methods - General requirements |
EN 60603-7-82 : 2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ (IEC 60603-7-82:2016) |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 62153-4-12:2009 | Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware - Absorbing clamp method |
EN 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
EN 60512-26-100:2008/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
EN 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
EN 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
EN 61169-16:2007 | Radio-frequency connectors - Part 16: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling - Characteristic impedance 50 ohms (75 ohms) (type N) |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
EN 60603-7:2009/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008/A1:2011) |
IEC 61169-16:2006 | Radio-frequency connectors - Part 16: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling - Characteristics impedance 50 ohms (75 ohms) (type N) |
IEC 60603-7-5:2010 | Connectors for electronic equipment - Part 7-5: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.