EN 60598-2-14:2009
Current
The latest, up-to-date edition.
Luminaires - Part 2-14: Particular requirements - Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment
16-04-2009
FOREWORD
14.1 Scope
14.2 Normative references
14.3 General test requirements
14.4 Definitions
14.5 Classification
14.6 Marking
14.7 Construction
14.8 External and internal wiring
14.9 Provision for earthing
14.10 Protection against electric shock
14.11 Resistance to dust, solid objects and moisture
14.12 Insulation resistance and electric strength
14.13 Creepage distances and clearances
14.14 Endurance and thermal test
14.15 Resistance to heat, fire and tracking
14.16 Screw terminals
14.17 Screwless terminals and electrical connections
Annex A (informative) - List of high voltage cables
specified in the relevant standards or equivalent
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
IEC 60598-2-14:2009 applies to luminaires for cold cathode tubular discharge lamps and similar equipment, operating on a no-load rated output voltage over 1 000 V but not exceeding 10 000 V, mainly used for general lighting, for indoor or outdoor applications and for supply voltages up to 1 000 V. This publication is intended to be read in conjunction with IEC 60598-1: Luminaires - Part 1: General requirements and tests. It was established on the basis of the seventh edition (2008) of that standard. This publication is intended to be read in conjunction with IEC 60598-1:2008.
Committee |
CLC/TC 34
|
DevelopmentNote |
To be read in conjunction with EN 60598-1. (07/2009)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
BS EN 60598-2-14:2009 | Identical |
NF EN 60598-2-14 : 2009 | Identical |
NEN EN IEC 60598-2-14 : 2009 | Identical |
CEI EN 60598-2-14 : 2010 | Identical |
IEC 60598-2-14:2009 | Identical |
VDE 0711-2-14 : 2009 | Identical |
DIN EN 60598-2-14 : 2009 | Identical |
NBN EN 60598-2-14 : 2009 | Identical |
UNE-EN 60598-2-14:2009 | Identical |
PN EN 60598-2-14 : 2009 | Identical |
EN 50107-1 : 2002 AMD 1 2004 | SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 1: GENERAL REQUIREMENTS |
EN 61050:1992/A1:1995 | TRANSFORMERS FOR TUBULAR DISCHARGE LAMPS HAVING A NON LOAD OUTPUT VOLTAGE EXCEEDING 1000 V (GENERALLY CALLED NEON TRANSFORMERS - GENERAL AND SAFETY REQUIREMENTS |
EN 50143:2009 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 61347-2-10:2001/corrigendum:2010 | LAMP CONTROLGEAR - PART 2-10: PARTICULAR REQUIREMENTS FOR ELECTRONIC INVERTORS AND CONVERTORS FOR HIGH-FREQUENCY OPERATION OF COLD TUBULAR DISCHARGE LAMPS (NEON TUBES) (IEC 61347-2-10:2000/A1:2008) |
EN 50107-2:2005 | Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV - Part 2: Requirements for earth-leakage and open-circuit protective devices |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 61347-2-10:2000+AMD1:2008 CSV | Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.