• There are no items in your cart

EN 60811-505:2012

Current

Current

The latest, up-to-date edition.

Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths

Published date

15-06-2012

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

IEC 60811-505:2012 gives the procedure for performing elongation tests at low temperature on extruded insulations and sheaths. IEC 60811-505:2012 cancels and replaces 8.3 and 8.4 of IEC 60811-1-4:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012. This publication is to be read in conjunction with IEC 60811-100:2012.

Committee
CLC/TC 20
DevelopmentNote
Supersedes EN 60811-1-4. To be read in conjunction with EN 60811-100. (06/2012)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

UNE-EN 50620:2017 Electric cables - Charging cables for electric vehicles
I.S. EN 50618:2014 ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS
I.S. EN 50620:2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
UNE 211067-2:2017 Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 400 kV (Um = 420 kV). Part 2: Cables with XLPE insulation and polyolefin compound sheath or high density polyethylene (HDPE) compound sheath.
UNE 211632-4A:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 4A: Cables with XLPE insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath.
UNE-HD 603-5X:2007 Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section X: Polyolefin sheathed cables without concentric conductor (Type 5X-1)
CEI EN 50620 : 1ED 2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
UNE-EN 50618:2015 Electric cables for photovoltaic systems
BS EN 50618:2014 Electric cables for photovoltaic systems (BT(DE/NOT)258)
I.S. EN 60811-504:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 504: MECHANICAL TESTS - BENDING TESTS AT LOW TEMPERATURE FOR INSULATION AND SHEATHS (IEC 60811-504:2012 (EQV))
UNE-HD 603-5N:2007 Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section N: PVC sheathed cables without concentric conductor. (Type 5N)
ESPECIFICACION UNE 0051:2017 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1 and type 3).
ESPECIFICACION UNE 0052:2017 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3).
BS EN 50620:2017 Electric cables. Charging cables for electric vehicles (BT(DE/NOT)259)
BS EN 60811-504:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Bending tests at low temperature for insulation and sheaths
EN 50618:2014 Electric cables for photovoltaic systems
EN 50620:2017 Electric cables - Charging cables for electric vehicles
UNE 211632-6A:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 6A: Cables with HEPR insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath.
UNE-EN 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
EN 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths

IEC 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
IEC 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
EN 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
EN 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
EN 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.