EN 60931-1:1996/A1:2003
Current
The latest, up-to-date edition.
SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
10-02-2003
Foreword
Section 1. General
1 Scope and object
2 Normative references
3 Definitions
4 Service conditions
Section 2. Quality requirements and tests
5 Test requirements
6 Classification of tests
7 Capacitance measurement and output calculation
8 Measurement of the tangent of the loss angle (tan delta)
of the capacitor
9 Voltage tests between terminals
10 Voltage tests between terminals and container
11 Test of internal discharge device
12 Sealing test
13 Thermal stability test
14 Measurement of the tangent of the loss angle (tan delta)
of the capacitor at elevated temperature
15 Lightning impulse voltage test between terminals and
container
16 Discharge test
17 Ageing test
18 Self-healing test
19 Destruction test
Section 3. Overloads
20 Maximum permissible voltage
21 Maximum permissible current
Section 4. Safety requirements
22 Discharge device
23 Container connections
24 Protection of the environment
25 Other safety requirements
Section 5. Markings
26 Marking of the unit
27 Marking of the bank
28 General
Section 6. Guide for installation and operation
29 Choice of the rated voltage
30 Operating temperature
31 Special service conditions
32 Overvoltages
33 Overload currents
34 Switching and protective devices and connections
35 Choice of creepage distance
36 Capacitors connected to systems with audio-frequency
remote control
37 Electromagnetic compatibility (EMC)
Annex A (normative) Additional definitions, requirements and
tests for power filter capacitors
Annex B (informative) Formulae for capacitors and installations
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Figures
Tables
Applies to capacitor units and capacitor banks meant to be used, particularly, for power factor correction of a.c. power systems having a rated voltage up to and including 1 000 V and frequency 15 Hz to 60 Hz.
Committee |
SR 33
|
DocumentType |
Guide
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
I.S. EN 60931-1:1997 | Identical |
NEN 10931-1 : 1997 | Identical |
NEN EN IEC 60931-1 : 1996 AMD 1 2003 | Identical |
SN EN 60931-1 : 1996 AMD 1 2003 | Identical |
BS EN 60931-1:1998 | Identical |
CEI EN 60931-1/A1 : 2003 | Identical |
PN EN 60931-1 : 2000 AMD 1 2004 | Identical |
NBN EN 60931-1 : 1997 AMD 1 2003 | Identical |
DIN EN 60931-1 : 2003 | Identical |
VDE 0560-48 : 2003 | Identical |
IEC 60931-1:1996/AMD1:2002 | Identical |
NF EN 60931-1 : 97 AMD 1 2003 | Identical |
UNE-EN 60931-1:1997 | Identical |
UNE-EN 60931-1/A1:2003 | Identical |
I.S. EN 60931-2:1999 | SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AN INCLUDING 1 KV - PART 2: AGEING TEST AND DESTRUCTION TEST |
EN 61642:1997 | Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors |
CEI EN 61921 : 2004 | POWER CAPACITORS - LOW VOLTAGE POWER FACTOR CORRECTION BANKS |
I.S. EN 61921:2003 | POWER CAPACITORS - LOW VOLTAGE POWER FACTOR CORRECTION BANKS |
BS EN 61921:2003 | Power capacitors. Low-voltage power factor correction banks |
I.S. EN 60931-3:1999 | SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AN INCLUDING 1 KV - PART 3: INTERNAL FUSES |
I.S. EN 61642:1999 | INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS |
BS EN 60931-3:1997 | Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1000 V Internal fuses |
CEI EN 60931-3 : 1997 | SHUNT POWER CAPACITORS OF THE NON-SELF HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV - PART 3: INTERNAL FUSES |
EN 60931-3:1996 | Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV - Part 3: Internal fuses |
EN 60931-2:1996 | Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV - Part 2: Ageing test and destruction test |
EN 61921:2003 | Power capacitors - Low-voltage power factor correction banks |
IEC 60252:1993 | A.C. motor capacitors |
EN 60252 : 94 AC 94 | A.C. MOTOR CAPACITORS |
IEC 60931-2:1995 | Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1000 V - Part 2: Ageing test and destruction test |
EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
ENV 61000-2-2 : 1993 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS |
EN 61048:2006/A1:2016 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006/A1:2015) |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
HD 597 S1:1992/corrigendum:1992 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS |
EN 61071-1 : 1996 | POWER ELECTRONIC CAPACITORS - PART 1: GENERAL |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 61071-1:1991 | Power electronic capacitors - Part 1: General |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
HD 207 : 200S1 | RECOMMENDATION FOR CAPACITORS FOR INDUCTIVE HEAT GENERATING PLANTS OPERATING AT FREQUENCIES BETWEEN 40 AND 24 000 HZ |
IEC 61049:1991 | Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
EN 61049:1993 | Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements |
IEC 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General |
EN 60831-1:2014/AC:2014 | SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION |
IEC 60143:1972 | Series capacitors for power systems |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 60831-1:2014 RLV | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation |
IEC 60931-3:1996 | Shunt capacitors of the non-self-healing type for AC power systems having a rated voltage up to and including 1000 V - Part 3: Internal fuses |
EN 60931-3:1996 | Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV - Part 3: Internal fuses |
IEC 60050-436:1990 | International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors |
EN 60931-2:1996 | Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV - Part 2: Ageing test and destruction test |
HD 525.1 : S1 AMD 1 | SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 660 V - GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY |
EN 60143 : 93 AC 94 | SERIES CAPACITORS FOR POWER SYSTEMS - GENERAL PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60110:1973 | Recommendation for capacitors for inductive heat generating plants operating at frequencies between 40 and 24 000 Hz |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.