The latest, up-to-date edition.

SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION

Amendment of

EN 60931-1:1996

Published date

10-02-2003

Sorry this product is not available in your region.

Foreword
Section 1. General
1 Scope and object
2 Normative references
3 Definitions
4 Service conditions
Section 2. Quality requirements and tests
5 Test requirements
6 Classification of tests
7 Capacitance measurement and output calculation
8 Measurement of the tangent of the loss angle (tan delta)
   of the capacitor
9 Voltage tests between terminals
10 Voltage tests between terminals and container
11 Test of internal discharge device
12 Sealing test
13 Thermal stability test
14 Measurement of the tangent of the loss angle (tan delta)
   of the capacitor at elevated temperature
15 Lightning impulse voltage test between terminals and
   container
16 Discharge test
17 Ageing test
18 Self-healing test
19 Destruction test
Section 3. Overloads
20 Maximum permissible voltage
21 Maximum permissible current
Section 4. Safety requirements
22 Discharge device
23 Container connections
24 Protection of the environment
25 Other safety requirements
Section 5. Markings
26 Marking of the unit
27 Marking of the bank
28 General
Section 6. Guide for installation and operation
29 Choice of the rated voltage
30 Operating temperature
31 Special service conditions
32 Overvoltages
33 Overload currents
34 Switching and protective devices and connections
35 Choice of creepage distance
36 Capacitors connected to systems with audio-frequency
   remote control
37 Electromagnetic compatibility (EMC)
Annex A (normative) Additional definitions, requirements and
         tests for power filter capacitors
Annex B (informative) Formulae for capacitors and installations
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Figures
Tables

Applies to capacitor units and capacitor banks meant to be used, particularly, for power factor correction of a.c. power systems having a rated voltage up to and including 1 000 V and frequency 15 Hz to 60 Hz.

Committee
SR 33
DocumentType
Guide
PublisherName
European Committee for Standards - Electrical
Status
Current

I.S. EN 60931-2:1999 SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AN INCLUDING 1 KV - PART 2: AGEING TEST AND DESTRUCTION TEST
EN 61642:1997 Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors
CEI EN 61921 : 2004 POWER CAPACITORS - LOW VOLTAGE POWER FACTOR CORRECTION BANKS
I.S. EN 61921:2003 POWER CAPACITORS - LOW VOLTAGE POWER FACTOR CORRECTION BANKS
BS EN 61921:2003 Power capacitors. Low-voltage power factor correction banks
I.S. EN 60931-3:1999 SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AN INCLUDING 1 KV - PART 3: INTERNAL FUSES
I.S. EN 61642:1999 INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS
BS EN 60931-3:1997 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1000 V Internal fuses
CEI EN 60931-3 : 1997 SHUNT POWER CAPACITORS OF THE NON-SELF HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV - PART 3: INTERNAL FUSES
EN 60931-3:1996 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV - Part 3: Internal fuses
EN 60931-2:1996 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV - Part 2: Ageing test and destruction test
EN 61921:2003 Power capacitors - Low-voltage power factor correction banks

IEC 60252:1993 A.C. motor capacitors
EN 60252 : 94 AC 94 A.C. MOTOR CAPACITORS
IEC 60931-2:1995 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1000 V - Part 2: Ageing test and destruction test
EN 61000-4-1:2007 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
ENV 61000-2-2 : 1993 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS
EN 61048:2006/A1:2016 AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006/A1:2015)
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 61048:2006+AMD1:2015 CSV Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements
HD 597 S1:1992/corrigendum:1992 COUPLING CAPACITORS AND CAPACITOR DIVIDERS
EN 61071-1 : 1996 POWER ELECTRONIC CAPACITORS - PART 1: GENERAL
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 61071-1:1991 Power electronic capacitors - Part 1: General
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
HD 207 : 200S1 RECOMMENDATION FOR CAPACITORS FOR INDUCTIVE HEAT GENERATING PLANTS OPERATING AT FREQUENCIES BETWEEN 40 AND 24 000 HZ
IEC 61049:1991 Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements
EN 61049:1993 Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements
IEC 60871-1:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General
EN 60831-1:2014/AC:2014 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
IEC 60143:1972 Series capacitors for power systems
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
IEC 60831-1:2014 RLV Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation
IEC 60931-3:1996 Shunt capacitors of the non-self-healing type for AC power systems having a rated voltage up to and including 1000 V - Part 3: Internal fuses
EN 60931-3:1996 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV - Part 3: Internal fuses
IEC 60050-436:1990 International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors
EN 60931-2:1996 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV - Part 2: Ageing test and destruction test
HD 525.1 : S1 AMD 1 SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 660 V - GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY
EN 60143 : 93 AC 94 SERIES CAPACITORS FOR POWER SYSTEMS - GENERAL PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60110:1973 Recommendation for capacitors for inductive heat generating plants operating at frequencies between 40 and 24 000 Hz
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.