EN 61000-4-19:2014
Current
The latest, up-to-date edition.
Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
22-08-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Test levels and wave profiles in
the frequency range 2 kHz to 150 kHz
6 Test equipment
7 Test setups
8 Test procedure
9 Evaluation of test results
10 Test report
Annex A (informative) - Interference sources,
victims and effects
Annex B (informative) - Selection of test levels
Annex C (informative) - Testing electricity meters
guideline
Annex D (informative) - Test wave profiles
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 61000-4-19:2014 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines:- test waveforms;- range of test levels;- test equipment;- test setup;- test procedures;- and verification procedures. These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000-4-13. Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000-4-16.Key words: electromagnetic compatibility, EMC
Committee |
CLC/TC 210
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NEN EN IEC 61000-4-19 : 2014 | Identical |
UNE-EN 61000-4-19:2015 | Identical |
VDE 0847-4-19 : 2015 | Identical |
NF EN 61000-4-19 : 2014 | Identical |
DIN EN 61000-4-19 : 2015 | Identical |
NBN EN 61000-4-19 : 2014 | Identical |
SN EN 61000-4-19:2014 | Identical |
I.S. EN 61000-4-19:2014 | Identical |
CEI EN 61000-4-19 : 2015 | Identical |
PN EN 61000-4-19 : 2014 | Identical |
BS EN 61000-4-19:2014 | Identical |
IEC 61000-4-19:2014 | Identical |
S.R. CLC/TR 50669:2017 | INVESTIGATION RESULTS ON ELECTROMAGNETIC INTERFERENCE IN THE FREQUENCY RANGE BELOW 150 KHZ |
PD CLC/TR 50669:2017 | Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz |
S.R. CLC/TR 50627:2015 | STUDY REPORT ON ELECTROMAGNETIC INTERFERENCE BETWEEN ELECTRICAL EQUIPMENT/SYSTEMS IN THE FREQUENCY RANGE BELOW 150 KHZ |
17/30365901 DC : 0 | BS EN 50160 AMD 2 - VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
UNE-EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
CLC/TR 50627:2015 | Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz |
PD CLC/TR 50627:2015 | Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz |
BS EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
CLC/TR 50669:2017 | Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz |
EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
IEC TS 62578:2015 | Power electronics systems and equipment - Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz |
EN 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
IEC TR 61000-2-5:2017 | Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
IEC 61000-3-8:1997 | Electromagnetic compatibility (EMC) - Part 3: Limits - Section 8: Signalling on low-voltage electrical installations - Emission levels, frequency bands and electromagnetic disturbance levels |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
CLC/TR 50579:2012 | ELECTRICITY METERING EQUIPMENT (A.C.) - SEVERITY LEVELS, IMMUNITY REQUIREMENTS AND TEST METHODS FOR CONDUCTED DISTURBANCES IN THE FREQUENCY RANGE 2 KHZ - 150 KHZ |
EN 50065-1:2011 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances |
EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
EN 61000-4-13:2002/A2:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015) |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
EN 55014-1:2017 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.