Introduction
1 Scope
2 Normative references
3 Definitions
4 Specifications of protective devices for
      conducted disturbance
4.1 General
4.2 Gas discharge tubes
4.3 Metal oxide varistors (MOV)
4.4 Expulsion-type arresters
4.5 Non-linear resistor type arresters
4.6 Avalanche-junction transient voltage suppressors
      (protective diodes)
4.7 Filters
4.8 Protection circuits
4.9 Safety arresters
4.10 Coaxial r.f. - circuit protectors
Annexes
A (informative) Survey of generic protection circuits
      and their application in surge protection
B (informative) A method of measuring the inductance
      of two-lead voltage limiting devices
C (informative) Survey on safety arresters and related
      safety philosophy
D (informative) A method of measuring the input
      impedance of mains filters
E (informative) Bibliography
ZA (normative) Normative references to International
      publications with their corresponding European
      publications

This part of 61000-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. It is intended to be used for the harmonization of existing or future specifications issued by protective device manufacturers, electronic equipment manufacturers, administrations and other ultimate buyers. Performance requirements shall be given in future IEC documents. This section covers protective devices currently being used for protection against induced HEMP transients on signal and low voltage power lines (nominal voltage up to 1 kV a.c.). General information can be applied also to high voltage lines. However, in these cases, the additional requirements for the protection levels of existing lightning arresters (especially gapless MO-arresters) are under consideration.

Committee
CLC/TC 210
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

CEI EN 61000-4-24 : 2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4: TESTING AND MEASUREMENT TECHNIQUES - SECTION 24: TEST METHODS FOR PROTECTIVE DEVICES FOR HEMP CONDUCTED DISTURBANCE - BASIC EMC PUBLICATION
PD CLC/TR 50373:2004 Wind turbines. Electromagnetic compatibility
CLC/TR 50373:2004 Wind turbines - Electromagnetic compatibility

IEC 60939-1:2010 Passive filter units for electromagnetic interference suppression - Part 1: Generic specification
IEC 60939-2:2005 Passive filter units for electromagnetic interference suppression - Part 2: Sectional specification - Passive filter units for which safety tests are appropriate - Test methods and general requirements
IEC 60099-1:1991+AMD1:1999 CSV Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems
IEC 61051-2:1991 Varistors for use in electronic equipment - Part 2: Sectional specification for surge suppression varistors
CISPR 17:2011 Methods of measurement of the suppression characteristics of passive EMC filtering devices
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 61051-1:2007 Varistors for use in electronic equipment - Part 1: Generic specification

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.