• Shopping Cart
    There are no items in your cart

EN 61094-1:2000

Current

Current

The latest, up-to-date edition.

Measurement microphones - Part 1: Specifications for laboratory standard microphones

Published date

21-11-2000

Sorry this product is not available in your region.

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Classification of laboratory standard microphone
   5.1 General
   5.2 Type designation
6 Characteristics of laboratory standard microphones
   6.1 Sensitivity
   6.2 Acoustic impedance
       6.2.1 General
       6.2.2 Equivalent volume of a microphone
   6.3 Upper limit of the dynamic range of a microphone
   6.4 Static pressure dependence of microphone sensitivity
   6.5 Temperature dependence of microphone sensitivity
   6.6 Humidity dependence of microphone sensitivity
   6.7 Electrical insulation resistance
   6.8 Stability of microphone sensitivity
   6.9 Pressure-equalizing leakage
7 Specifications
   7.1 Mechanical dimensions
   7.2 Ground shield reference configuration
   7.3 Electroacoustical specifications
   7.4 Identification markings
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Specifies mechanical dimensions and certain electroacoustic characteristics for condenser microphones used as laboratory standards for the realization of the unit of sound pressure and for sound pressure measurements of the highest attainable accuracy. The specifications are intended to ensure that primary calibration by the reciprocity method can be readily carried out. Establishes a system for classifying laboratory standard condenser microphones into a number of types according to their dimensions and properties.

Committee
CLC/SR 29
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

BS EN 60318-3:2015 Electroacoustics. Simulators of human head and ear Acoustic coupler for the calibration of supra-aural earphones used in audiometry
CEI EN 60942 : 2004 ELECTROACOUSTICS SOUND CALIBRATORS
CEI EN 61094-3 : 1997 ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 3: PRIMARY METHOD FOR FREE-FIELD CALIBRATION OF LABORATORY STANDARD MICROPHONES BY THE RECIPROCITY TECHNIQUE
I.S. EN 61183:1995 ELECTROACOUSTICS - RANDOM-INCIDENCE AND DIFFUSE-FIELD CALIBRATION OF SOUND LEVEL METERS
BS EN 61672-2 : 2013 ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS
I.S. EN IEC 60942:2018 ELECTROACOUSTICS - SOUND CALIBRATORS
CEI EN 61672-2 : 2014 ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS
UNE-EN 61094-2:2011 Electroacoustics - Measurement microphones -- Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique
UNE-EN 61094-3:2017 Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique
EN 61094-2:2009 Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique
EN 61329:1996 Sound system equipment - Methods of measuring and specifying the performance of sounders (electroacoustic transducers for tone production)
EN 61094-5:2016 Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison
EN 62585 : 2012 ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER (IEC 62585:2012)
EN 61094-6:2005 Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
EN 61094-8:2012/AC:2013 Measurement microphones — Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison
EN 61183:1994 Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters
BS EN 60942:2003 Electroacoustics. Sound calibrators
BS EN 61094-6:2005 Measurement microphones Electrostatic actuators for determination of frequency response
I.S. EN 61842:2002 MICROPHONES AND EARPHONES FOR SPEECH COMMUNICATIONS
BS EN 61842:2002 Microphones and earphones for speech communications
I.S. EN 60942:2003 ELECTROACOUSTICS - SOUND CALIBRATORS
I.S. EN 60318-2:1999 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 2: AN INTERIM ACOUSTIC COUPLER FOR THE CALIBRATION OF AUDIOMETRIC EARPHONES IN THE EXTENDED HIGH-FREQUENCY RANGE
UNE-EN 61094-5:2017 Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison
EN 61094-3:2016/AC:2017-01 ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 3: PRIMARY METHOD FOR FREE-FIELD CALIBRATION OF LABORATORY STANDARD MICROPHONES BY THE RECIPROCITY TECHNIQUE
CEI EN 61094-6 : 2005 MEASUREMENT MICROPHONES PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE
BS EN 61094-5:2002 Measurement microphones Methods for pressure calibration of working standard microphones by comparison
BS EN 61094-8:2012 Electroacoustics. Measurement microphones Methods for determining the free-field sensitivity of working standard microphones by comparison
BS EN 60318-2:1998 Electroacoustics. Simulators of human head and ear An interim acoustic coupler for the calibration of audiometric earphones in the extended high-frequency range
BS EN 61094-3:2016 Electroacoustics. Measurement microphones Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique
I.S. EN 60318-3:2015 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 3: ACOUSTIC COUPLER FOR THE CALIBRATION OF SUPRA-AURAL EARPHONES USED IN AUDIOMETRY
I.S. EN 61672-2:2013 ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS
CEI EN 61094-8 : 2013 ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 8: METHODS FOR FREE-FIELD CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON
CEI EN 61094-2 : 2014 ELECTROACOUSTICS - MEASUREMENT MICROPHONES PART 2: PRIMARY METHOD FOR THE PRESSURE CALIBRATION OF LABORATORY STANDARD MICROPHONES BY THE RECIPROCITY TECHNIQUE
BS EN 61094-2:2009 Electroacoustics. Measurement microphones Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique
CEI EN 61842 : 2002 MICROPHONES AND EARPHONES FOR SPEECH COMMUNICATIONS
CEI EN 61329 : 1998 SOUND SYSTEM EQUIPMENT METHODS OF MEASURING AND SPECIFYING THE PERFORMANCE OF SOUNDERS (ELECTROACOUSTIC TRANSDUCERS FOR TONE PRODUCTION)
IEC 61842:2002 Microphones and earphones for speech communications
UNE-EN 60318-1:2010 Electroacoustics - Simulators of human head and ear -- Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones
CEI EN 61094-5 : 2002 ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 5: METHODS FOR PRESSURE CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON
EN IEC 60942:2018 Electroacoustics - Sound calibrators
BS EN 62585:2012 Electroacoustics. Methods to determine corrections to obtain the free-field response of a sound level meter
CEI EN 62585 : 2013 ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER
UNE-EN 61094-8:2013 Measurement microphones. Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison
UNE-EN 62585:2013 Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter
I.S. EN 61094-8:2012 MEASUREMENT MICROPHONES - PART 8: METHODS FOR DETERMINING THE FREE-FIELD SENSITIVITY OF WORKING STANDARD MICROPHONES BY COMPARISON (IEC 61094-8:2012 (EQV))
I.S. EN 61329:1999 SOUND SYSTEM EQUIPMENT - METHODS OF MEASURING AND SPECIFYING THE PERFORMANCE OF SOUNDERS (ELECTROACOUSTIC TRANSDUCERS FOR TONE PRODUCTION)
I.S. EN 61094-5:2016 ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 5: METHODS FOR PRESSURE CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON
I.S. EN 61094-6:2005 MEASUREMENT MICROPHONES - PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE
I.S. EN 61094-3:2016 ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 3: PRIMARY METHOD FOR FREE-FIELD CALIBRATION OF LABORATORY STANDARDMICROPHONES BY THE RECIPROCITY TECHNIQUE
EN 60318-2:1998 Electroacoustics - Simulators of human head and ear - Part 2: An interim acoustic coupler for the calibration of audiometric earphones in the extended high-frequency range
EN 60318-3:2015 Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry
EN 61672-2:2013/A1:2017 ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS (IEC 61672-2:2013/A1:2017)

IEC 60050-801:1994 International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.