EN 61094-2:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique
31-03-2022
16-04-2009
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Principles of pressure calibration by reciprocity
5.1 General principles
5.1.1 General
5.1.2 General principles using three microphones
5.1.3 General principles using two microphones
and an auxiliary sound source
5.2 Basic expressions
5.3 Insert voltage technique
5.4 Evaluation of the acoustic transfer impedance
5.5 Heat-conduction correction
5.6 Capillary tube correction
5.7 Final expressions for the pressure sensitivity
5.7.1 Method using three microphones
5.7.2 Method using two microphones and
an auxiliary sound source
6 Factors influencing the pressure sensitivity of
microphones
6.1 General
6.2 Polarizing voltage
6.3 Ground-shield reference configuration
6.4 Pressure distribution over the diaphragm
6.5 Dependence on environmental conditions
6.5.1 Static pressure
6.5.2 Temperature
6.5.3 Humidity
6.5.4 Transformation to reference environmental
conditions
7 Calibration uncertainty components
7.1 General
7.2 Electrical transfer impedance
7.3 Acoustic transfer impedance
7.3.1 General
7.3.2 Coupler properties
7.3.3 Microphone parameters
7.4 Imperfection of theory
7.5 Uncertainty on pressure sensitivity level
Annex A (normative) - Heat conduction and viscous
losses in a closed cavity
Annex B (normative) - Acoustic impedance of a
capillary tube
Annex C (informative) - Examples of cylindrical couplers
for calibration of microphones
Annex D (informative) - Environmental influence on the
sensitivity of microphones
Annex E (informative) - Methods for determining
microphone parameters
Annex F (informative) - Physical properties of humid air
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
IEC 61094-2:2009 is applicable to laboratory standard microphones meeting the requirements of IEC 61094-1 and other types of condenser microphone having the same mechanical dimensions and specifies a primary method of determining the complex pressure sensitivity so as to establish a reproducible and accurate basis for the measurement of sound pressure. This second edition cancels and replaces the first edition published in 1992. This second edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- an update of Clause 6 to fulfil the requirements of ISO/IEC Guide 98-3;
- an improvement of the heat conduction theory in Annex A;
- a revision of Annex F: Physical properties of humid air.
Committee |
CLC/SR 29
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NBN EN 61094-2 : 2009 | Identical |
NEN EN IEC 61094-2 : 2009 | Identical |
PN EN 61094-2 : 2010 | Identical |
NEN 11094-2 : 1994 | Identical |
I.S. EN 61094-2:1994 | Identical |
SN EN 61094-2 : 1993 | Identical |
NF EN 61094-2 : 2009 | Identical |
UNE-EN 61094-2:2011 | Identical |
DIN EN 61094-2:2009-09 | Identical |
CEI EN 61094-2 : 2014 | Identical |
IEC 61094-2:2009 | Identical |
BS EN 61094-2:2009 | Identical |
I.S. EN 61094-2:2009 | Identical |
UNE-EN 61094-2:2009 | Identical |
CEI EN 60942 : 2004 | ELECTROACOUSTICS SOUND CALIBRATORS |
CEI EN 61094-3 : 1997 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 3: PRIMARY METHOD FOR FREE-FIELD CALIBRATION OF LABORATORY STANDARD MICROPHONES BY THE RECIPROCITY TECHNIQUE |
UNE-EN 61094-3:2017 | Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique |
EN 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-6:2005 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
EN 61094-8:2012/AC:2013 | Measurement microphones — Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
BS EN 60942:2003 | Electroacoustics. Sound calibrators |
BS EN 61094-6:2005 | Measurement microphones Electrostatic actuators for determination of frequency response |
I.S. EN 60942:2003 | ELECTROACOUSTICS - SOUND CALIBRATORS |
UNE-EN 61094-5:2017 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-3:2016/AC:2017-01 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 3: PRIMARY METHOD FOR FREE-FIELD CALIBRATION OF LABORATORY STANDARD MICROPHONES BY THE RECIPROCITY TECHNIQUE |
CEI EN 61094-6 : 2005 | MEASUREMENT MICROPHONES PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE |
BS EN 61094-5:2002 | Measurement microphones Methods for pressure calibration of working standard microphones by comparison |
BS EN 61094-8:2012 | Electroacoustics. Measurement microphones Methods for determining the free-field sensitivity of working standard microphones by comparison |
BS EN 61094-3:2016 | Electroacoustics. Measurement microphones Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique |
CEI EN 61094-8 : 2013 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 8: METHODS FOR FREE-FIELD CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON |
UNE-EN 60318-1:2010 | Electroacoustics - Simulators of human head and ear -- Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones |
UNE-EN 61094-8:2013 | Measurement microphones. Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
I.S. EN 61094-8:2012 | MEASUREMENT MICROPHONES - PART 8: METHODS FOR DETERMINING THE FREE-FIELD SENSITIVITY OF WORKING STANDARD MICROPHONES BY COMPARISON (IEC 61094-8:2012 (EQV)) |
I.S. EN 61094-5:2016 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 5: METHODS FOR PRESSURE CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON |
I.S. EN 61094-6:2005 | MEASUREMENT MICROPHONES - PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE |
I.S. EN 61094-3:2016 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 3: PRIMARY METHOD FOR FREE-FIELD CALIBRATION OF LABORATORY STANDARDMICROPHONES BY THE RECIPROCITY TECHNIQUE |
EN 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
ISO 9613-1:1993 | Acoustics Attenuation of sound during propagation outdoors Part 1: Calculation of the absorption of sound by the atmosphere |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.