Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison
02-09-2016
Applies to working standard microphones with removable protection grids meeting the requirements of EN 61094-4 and to laboratory standard microphones meeting the requirements of EN 61094-1. Describes methods of determining the pressure sensitivity by comparison with either a laboratory standard microphone that has been calibrated according to EN 61094-2, or another working standard microphone that has been calibrated according to this part of EN 61094.
| Committee |
CLC/SR 29
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Standards | Relationship |
| CEI EN 61094-5 : 2002 | Identical |
| I.S. EN 61094-5:2016 | Identical |
| NEN EN IEC 61094-5 : 2016 | Identical |
| NBN EN 61094-5 : 2016 | Identical |
| PN EN 61094-5 : 2016 | Identical |
| OVE EN 61094-5: 2020 03 01 | Identical |
| DIN EN 61094-5:2016-12 | Identical |
| DIN EN 61094-5:2015-07 (Draft) | Identical |
| NF EN 61094-5 : 2016 | Identical |
| BS EN 61094-5:2002 | Identical |
| IEC 61094-5:2016 | Identical |
| BS EN 61094-5:2016 | Identical |
| UNE-EN 61094-5:2017 | Identical |
| CEI EN 61094-5:2017-03 | Identical |
| BS EN 61672-3:2013 | Electroacoustics. Sound level meters Periodic tests |
| CEI EN 60942 : 2004 | ELECTROACOUSTICS SOUND CALIBRATORS |
| BS EN 61672-2 : 2013 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
| CEI EN 61672-2 : 2014 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
| EN 62585:2012 | Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter |
| EN 61672-3:2013 | Electroacoustics - Sound level meters - Part 3: Periodic tests |
| EN 61094-6:2005 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
| EN 61094-8:2012/AC:2013 | Measurement microphones — Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
| BS EN 60942:2003 | Electroacoustics. Sound calibrators |
| BS EN 61094-6:2005 | Measurement microphones Electrostatic actuators for determination of frequency response |
| I.S. EN 60942:2003 | ELECTROACOUSTICS - SOUND CALIBRATORS |
| I.S. EN IEC 60942:2018 | ELECTROACOUSTICS - SOUND CALIBRATORS |
| CEI EN 61094-6 : 2005 | MEASUREMENT MICROPHONES PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE |
| BS EN 61094-8:2012 | Electroacoustics. Measurement microphones Methods for determining the free-field sensitivity of working standard microphones by comparison |
| I.S. EN 61672-2:2013 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS |
| CEI EN 61094-8 : 2013 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 8: METHODS FOR FREE-FIELD CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON |
| CEI EN 61672-3 : 2014 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 3: PERIODIC TESTS |
| I.S. EN 61672-3:2013 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 3: PERIODIC TESTS |
| EN IEC 60942:2018 | Electroacoustics - Sound calibrators |
| BS EN 62585:2012 | Electroacoustics. Methods to determine corrections to obtain the free-field response of a sound level meter |
| CEI EN 62585 : 2013 | ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER |
| I.S. EN 61094-8:2012 | MEASUREMENT MICROPHONES - PART 8: METHODS FOR DETERMINING THE FREE-FIELD SENSITIVITY OF WORKING STANDARD MICROPHONES BY COMPARISON (IEC 61094-8:2012 (EQV)) |
| I.S. EN 61094-6:2005 | MEASUREMENT MICROPHONES - PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE |
| EN 61672-2:2013/A1:2017 | ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS (IEC 61672-2:2013/A1:2017) |
| UNE-EN 62585:2013 | Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter |
| UNE-EN 61094-8:2013 | Measurement microphones. Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
| EN 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
| IEC 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
| EN 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
| IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
| EN 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
| IEC 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
| ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.