EN 61334-5-1:2001
Current
The latest, up-to-date edition.
Distribution automation using distribution line carrier systems - Part 5-1: Lower layer profiles - The spread frequency shift keying (S-FSK) profile
23-07-2001
FOREWORD
1 General
1.1 Scope and object
1.2 Normative references
1.3 Definitions
2 Modulation
2.1 Purpose
2.2 Spread frequency shift keying (S-FSK) principle
2.3 Spreading
2.4 Performance tests
2.4.1 Purpose
2.4.2 White noise BER tests
2.4.3 Narrowband interferer BER tests
2.4.4 Impulsive noise BER tests
3 Physical layer
3.1 Purpose
3.2 Transmission method
3.2.1 Coding
3.2.2 Bit timing
3.2.3 Frame timing
3.2.4 Slot timing
3.3 Packet encapsulation
3.3.1 Purpose
3.3.2 Byte and bit ordering
3.3.3 Preamble and start subframe delimiter
3.3.4 Pause
3.4 Physical layer services definitions
3.4.1 General description
3.4.2 P_Data.request
3.4.3 P_Data.confirm
3.4.4 P_Data.indication
3.4.5 P_Sync.request
3.4.6 P_Sync.indication
3.5 Sending and receiving physical sublayer
3.5.1 Sending
3.5.2 Receiving
3.5.3 Synchronization - desynchronization of a server
3.5.4 Physical state transition tables
3.5.5 Transition table description
4 Medium access control sublayer (MAC)
4.1 MAC service specification
4.1.1 Purpose
4.1.2 Characteristics
4.1.3 Overview of the services
4.1.4 MA_Data.request
4.1.5 MA_Data.confirm
4.1.6 MA_Data.indication
4.1.7 MA_Sync.indication
4.2 MAC frame structure
4.2.1 Frame indicator
4.2.2 Long MAC frame format
4.2.3 Elements of the long MAC frame
4.2.4 Invalid long MAC frame
4.3 Medium access control method
4.3.1 Functional model
4.3.2 Transmission description
4.3.3 Reception description
4.3.4 MAC management description
4.3.5 Formal specification
4.3.6 Medium access state table
4.3.7 Transition table description
Annex A (normative) Description of error values
Annex ZA (normative) Normative references to international
publications with their corresponding European publications
Bibliography
Describes the requirements of S-FSK (frequency shift keying modulation) in conjunction with the services provided by the physical layer entity and the MAC sublayer. The transmission medium is assumed to be the distribution network on both MV or LV level. To be used in conjunction with EN 61334-4-32.
Committee |
CLC/TC 57
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
UNE-EN 61334-5-1:2001 | Identical |
CEI EN 61334-5-1 : 2002 | Identical |
IEC 61334-5-1:2001 | Identical |
I.S. EN 61334-5-1:2001 | Identical |
NBN EN 61334 5-1 : 2002 | Identical |
PN EN 61334-5-1 : 2004 | Identical |
NEN EN IEC 61334-5-1 : 2001 | Identical |
SN EN 61334-5-1 : 2001 | Identical |
NF EN 61334-5-1 : 2001 | Identical |
DIN EN 61334-5-1:2001-12 | Identical |
BS EN 61334-5-1:2001 | Identical |
BS EN 62056-1-0:2015 | Electricity metering data exchange. The DLMS/COSEM suite Smart metering standardization framework |
S.R. CLC/TR 50669:2017 | INVESTIGATION RESULTS ON ELECTROMAGNETIC INTERFERENCE IN THE FREQUENCY RANGE BELOW 150 KHZ |
I.S. EN 62056-1-0:2015 | ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 1-0: SMART METERING STANDARDIZATION FRAMEWORK |
EN 61334-4-512:2002 | Distribution automation using distribution line carrier systems - Part 4-512: Data communication protocols - System management using profile 61334-5-1 - Management Information Base (MIB) |
EN 62056-1-0:2015 | Electricity metering data exchange - The DLMS/COSEM suite - Part 1-0: Smart metering standardization framework |
PD CLC/TR 50669:2017 | Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz |
BS EN 62056-8-3:2013 | Electricity metering data exchange. The DLMS/COSEM suite Communication profile for PLC S-FSK neighbourhood networks |
CEI EN 62056-8-3 : 2014 | ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 8-3: THE PLC S-FSK COMMUNICATION PROFILE FOR NEIGHBOURHOOD NETWORKS |
I.S. EN 61334-4-512:2002 | DISTRIBUTION AUTOMATION USING DISTRIBUTION LINE CARRIER SYSTEMS - PART 4-512: DATA COMMUNICATION PROTOCOLS - SYSTEM MANAGEMENT USING PROFILE 61334-5-1 - MANAGEMENT INFORMATION BASE (MIB) |
I.S. EN 62056-6-2:2016 | ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES |
EN IEC 62056-6-2:2018 | Electricity metering data exchange - The DLMS/COSEM suite - Part 6-2: COSEM interface classes |
CLC/TR 50627:2015 | Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz |
S.R. CLC/TR 50627:2015 | STUDY REPORT ON ELECTROMAGNETIC INTERFERENCE BETWEEN ELECTRICAL EQUIPMENT/SYSTEMS IN THE FREQUENCY RANGE BELOW 150 KHZ |
CEI EN 62056-6-2 : 2014 | ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES |
BS EN 62056-6-2:2016 | Electricity metering data exchange. The DLMS/COSEM suite COSEM interface classes |
PD CLC/TR 50627:2015 | Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz |
BS EN 61334-4-512:2002 | Distribution automation using distribution line carrier systems. Data communication protocols System management using profile 61334-5-1. Management Information Base (MIB) |
I.S. EN IEC 62056-6-2:2018 | ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES |
I.S. EN 62056-8-3:2013 | ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 8-3: COMMUNICATION PROFILE FOR PLC S-FSK NEIGHBOURHOOD NETWORKS (IEC 62056-8-3:2013 (EQV)) |
CLC/TR 50669:2017 | Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz |
EN 62056-8-3:2013 | Electricity metering data exchange - The DLMS/COSEM suite - Part 8-3: Communication profile for PLC S-FSK neighbourhood networks |
ISO/IEC 7498-3:1997 | Information technology — Open Systems Interconnection — Basic Reference Model: Naming and addressing |
ISO/IEC 7498-1:1994 | Information technology — Open Systems Interconnection — Basic Reference Model: The Basic Model |
IEC 61334-4-32:1996 | Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 32: Data link layer - Logical link control (LLC) |
IEC 61334-4-511:2000 | Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol |
EN 50065-1:2011 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances |
IEC 61334-4-1:1996 | Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 1: Reference model of the communication system |
IEC 61334-4-512:2001 | Distribution automation using distribution line carrier systems - Part 4-512: Data communication protocols - System management using profile 61334-5-1 - Management Information Base (MIB) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.