EN 61378-2:2001
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Convertor transformers - Part 2: Transformers for HVDC applications
01-01-2004
18-04-2001
1 General
1.1 Scope
1.2 Service conditions
2 Normative references
3 Definitions
4 List of variables
5 Ratings
5.1 General
5.2 Rated voltage
5.3 Rated current
5.4 Rated frequency
5.5 Rated power
6 Tolerances
6.1 General
6.2 Short-circuit impedance tolerances
6.3 Guarantees
7 Losses
7.1 General
7.2 No-load loss
7.3 Load loss under rated power-frequency
conditions
7.4 Load loss under service conditions
7.5 Determination of hot-spot temperature
8 Insulation levels
8.1 Line windings
8.2 Valve windings
8.3 Induced voltage level with partial discharge
measurements
9 Sound level
9.1 General
9.2 Guaranteed sound-power levels
9.3 Sound-power level at site
10 Testing
10.1 General
10.2 Tests
10.3 Load-loss measurements
10.4 Factory dielectric tests
10.5 Temperature-rise test
10.6 Load-current test
10.7 Determination of transformer sound-power
level
11 High-frequency modelling
12 Loading of transformer above rating
13 Bushings
13.1 AC bushings
13.2 Valve winding bushings
14 Tap-changer
14.1 General
14.2 Current wave shape
Bibliography
Table 1 - Test conditions for three-winding
transformers
Annex ZA (normative) Normative references to
international publications
with their corresponding
European publications
This part of EN 61378 applies to oil-immersed three-phase and -single-phase convertor transformers for use in HVDC power transmission. It applies to transformers having two, three or multiple windings. This standard does not apply to convertor transformers for industrial applications (see EN 61378-1) and to convertor transformers for traction applications (see EN 60310).
Committee |
CLC/TC 14
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
NBN EN 61378-2 : 2001 | Identical |
VDE 0532-42 : 2001 | Identical |
BS EN 61378-2:2001 | Identical |
DIN EN 61378-2 : 2001 | Identical |
NF EN 61378-2 : 2001 | Identical |
I.S. EN 61378-2:2001 | Identical |
UNE-EN 61378-2:2002 | Identical |
SN EN 61378-2 : 2001 | Identical |
NEN EN IEC 61378-2 : 2001 | Identical |
IEC 61378-2:2001 | Identical |
PN EN 61378-2 : 2010 | Identical |
CEI EN 61378-2 : 2002 | Identical |
CEI EN 60076-14 : 2014 | POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS |
EN IEC/IEEE 65700 : 2018 | BUSHINGS FOR DC APPLICATION (IEC/IEEE 65700-19-03:2014) |
UNE-EN 61378-1:2012 | Convertor transformers -- Part 1: Transformers for industrial applications |
BS EN 60076-14:2013 | Power transformers Liquid-immersed power transformers using high-temperature insulation materials |
UNE-EN 60076-14:2014 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
I.S. EN 60076-14:2013 | POWER TRANSFORMERS - PART 14: LIQUIDIMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS (IEC 60076-14:2013 (EQV)) |
I.S. EN IEC/IEEE 65700:2018 | BUSHINGS FOR DC APPLICATION |
EN 60076-14:2013 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60214:1989 | On-load tap-changers |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
IEC 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
IEC 60354:1991 | Loading guide for oil-immersed power transformers |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.