EN 61970-405:2007
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Energy management system application program interface (EMS-API) - Part 405: Generic Eventing and Subscription (GES)
01-09-2010
28-09-2007
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Generic Eventing and Subscription (Normative)
4.1 Overview
4.1.1 General
4.1.2 Suitability of the GES to the integration of
a variety of application categories
4.1.3 Suitability of the GES to the integration
beyond the control center
4.1.4 Suitability of the GES to the integration of
tightly coupled and loosely coupled applications
(informative)
4.2 Using GES A&E Simple Eventing for Generic Messaging
4.2.1 General
4.2.2 GES messages
4.2.3 Eventing and Subscription topic trees (informative)
4.2.4 Subscription filtering
4.2.5 GES Publish/Subscribe wildcards
4.2.6 Browsing IECTC57 namespaces with GES
5 Generic Event Subscription Alarms and Events
5.1 Background (informative)
5.2 SCADA use case (informative)
5.3 Data model (normative)
5.4 Messages (normative)
5.5 Interface (normative)
5.5.1 Objects and interfaces
5.5.2 Server and Session interfaces
5.5.3 Browse interfaces
5.5.4 Client interfaces
5.5.5 Mapping DAIS A&E to IEC 61970-3XX series
Annex A (informative) Proxy Event Subscription sequence
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
Specifies a generalized interface for efficient exchange of messages. Takes into account the latencies caused by a Local Area Network (LAN) providing efficient data exchange also over Local Area Networks. The Generic Eventing and Subscription API is expected to provide one of the primary means for accomplishing application integration.
Committee |
CLC/TC 57
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
CEI EN 61970-405 : 2015 | Identical |
PN EN 61970-405 : 2008 | Identical |
IEC 61970-405:2007 | Identical |
NEN EN IEC 61970-405 : 2007 | Identical |
BS EN 61970-405:2007 | Identical |
DIN EN 61970-405:2008-02 | Identical |
NBN EN 61970-405 : 2008 | Identical |
UNE-EN 61970-405:2007 | Identical |
I.S. EN 61970-405:2007 | Identical |
NF EN 61970-405 : 2006 PR | Identical |
PNE-prEN 61970-405 | Identical |
EN 61970-402:2008 | Energy management system application program interface (EMS-API) - Part 402: Common services |
BS EN 61970-402:2008 | Energy management system application program interface (EMS-API) Common services |
CEI EN 61970-402 : 2015 | ENERGY MANAGEMENT SYSTEM APPLICATION PROGRAM INTERFACE (EMS-API) - PART 402: COMMON SERVICES |
I.S. EN 61970-403:2008 | ENERGY MANAGEMENT SYSTEM APPLICATION PROGRAM INTERFACE (EMS-API) - PART 403: GENERIC DATA ACCESS |
BS EN 61970-403:2008 | Energy management system application program interface (EMS-API) Generic data access |
I.S. EN 61970-402:2008 | ENERGY MANAGEMENT SYSTEM APPLICATION PROGRAM INTERFACE (EMS-API) - PART 402: COMMON SERVICES |
EN 61970-403:2008 | ENERGY MANAGEMENT SYSTEM APPLICATION PROGRAM INTERFACE (EMS-API) - PART 403: GENERIC DATA ACCESS |
IEC 61850-7-2:2010 | Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI) |
IEC 61970-301:2016 | Energy management system application program interface (EMS-API) - Part 301: Common information model (CIM) base |
IEC TS 61970-2:2004 | Energy management system application program interface (EMS-API) - Part 2: Glossary |
EN 61970-301:2017 | Energy management system application program interface (EMS-API) - Part 301: Common information model (CIM) base |
IEC TS 61970-401:2005 | Energy management system application program interface (EMS-API) - Part 401: Component interface specification (CIS) framework |
IEC 61968-3:2017 | Application integration at electric utilities - System interfaces for distribution management - Part 3: Interface for network operations |
IEC 61970-402:2008 | Energy management system application program interface (EMS-API) - Part 402: Common services |
CLC/TS 61970-2:2005 | Energy management system application program interface (EMS-API) - Part 2: Glossary |
IEC 61970-1:2005 | Energy management system application program interface (EMS-API) - Part 1: Guidelines and general requirements |
EN 61970-1:2006 | Energy management system application program interface (EMS-API) - Part 1: Guidelines and general requirements |
IEC 61968-1:2012 | Application integration at electric utilities - System interfaces for distribution management - Part 1: Interface architecture and general recommendations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.