• EN 62220-1-1:2015

    Current The latest, up-to-date edition.

    Medical electrical equipment - Characteristics of digital x-ray imaging devices - Part 1-1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging

    Available format(s): 

    Language(s): 

    Published date:  12-06-2015

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements
    5 Corrections of RAW DATA
    6 Determination of the DETECTIVE QUANTUM
      EFFICIENCY
    7 Format of conformance statement
    8 Accuracy
    Annex A (normative) - Determination of LAG EFFECTS
    Annex B (informative) - Calculation of the input NOISE POWER
            SPECTRUM
    Bibliography
    Index of defined terms used in this particular standard
    Annex ZA (normative) - Normative references to international
             Publications with their corresponding European publications
    Annex ZZ (informative) - Coverage of Essential Requirements
             of EU Directives

    Abstract - (Show below) - (Hide below)

    IEC 62220-1-1:2015 specifies the method for the determination of the DETECTIVE QUANTUM EFFICIENCY (DQE) of DIGITAL X-RAY IMAGING DEVICES as a function of AIR KERMA and of SPATIAL FREQUENCY for the working conditions in the range of the medical application as specified by the MANUFACTURER. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories. This first edition of IEC 62220-1-1 cancels and replaces IEC 62220-1:2003. It constitutes a technical revision of IEC 62220-1:2003 and assures a better alignment with the other parts of the IEC 62220 series. The main changes are as follows:- necessary modifications have been applied as a consequence of taking into account IEC 61267:2005. This influences HVL values and SNRin2;- the method for the determination of LAG EFFECTS now considers lag and ghosting compensation;- as part of the MTF determination, the method of obtaining the final averaged MTF has been restricted (only averaging of the ESF is allowed); - a description of (optionally) obtaining the diagonal (45°) MTF and NPS has been added.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 62
    Development Note Supersedes EN 62220-1. (06/2015)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
    EN 62220-1-2 : 2007 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography
    ISO 15529:2010 Optics and photonics Optical transfer function Principles of measurement of modulation transfer function (MTF) of sampled imaging systems
    EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
    IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
    IEC 62220-1-2:2007 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography
    EN 61262-5:1994 Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 5: Determination of the detective quantum efficiency
    IEC 60601-2-54:2009+AMD1:2015 CSV Medical electrical equipment - Part 2-54: Particular requirementsfor the basic safety and essential performance of X-ray equipmentfor radiography and radioscopy
    ISO 12233:2017 Photography — Electronic still picture imaging — Resolution and spatial frequency responses
    EN 62220-1-3:2008 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-3: Determination of the detective quantum efficiency - Detectors used in dynamic imaging
    EN 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
    IEC 61262-5:1994 Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 5: Determination of the detective quantum efficiency
    IEC 62220-1-3:2008 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-3: Determination of the detective quantum efficiency - Detectors used in dynamic imaging
    EN 60601-2-54:2009/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY
    IEC 61267:2005 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective